A vSphere 8 environment, with or without Aria 8 components, reaches VMware Cloud Foundation 9.1.1 by convergence: VCF Installer turns its vCenter and hosts into the management domain of a new VCF Instance, in a new or an existing fleet, and deploys the missing VCF components12. A standalone vCenter that should join a running instance is imported as a workload domain3, and VCF 5.2.x or 9.0.x is upgraded1. Convergence starts directly at 9.1.14. The baseline here is 9.1.1 with the October 12, 2026, patches and vCenter 9.1.1.0200 of November 19, 2026.
Three effects are hard to take back. Any vCenter or Aria Operations upgrade before convergence starts a 90-day license evaluation5, the cluster hosting the vCenter VM becomes the management domain’s primary cluster6, and an NSX deployed during the run limits later upgrade targets3. Our recommendation is to choose each vCenter’s route, as in the staged path from vSphere 8, and clear the gates below before any change.
Choosing the route
Convergence has separate scenarios for environments with no Aria products, with Aria Operations, with Aria Automation and with both, and a vSphere Foundation 9.1 environment that already runs VCF management services cannot be converged to VCF 9.11. Import takes a standalone vCenter, with or without NSX Manager, into an instance at VCF 9.0 or later as a new workload domain, all its clusters together3. The VCF Upgrade Planning Tool covers convergence scenarios too7.
Convergence guidance covers only the management domain, which forms a fleet’s first VCF Instance and sets its version1. With several vCenter instances, one is converged first and the others imported as workload domains or converged as another instance’s management domain38.
A VCF 5.2.x instance takes a sequential or skip-level upgrade, and anything older first brings every domain to 5.2.x9. Releases of 5.2.x and 9.0.x published before 9.1.1 upgrade directly, starting with VCF Operations 9.1.1, which on 5.2.x means Aria Operations and its cloud proxy49. From 5.2.1, the SDDC Manager 9.1.1.0200 notes require 5.2.2 or 5.2.3 first10, while the Interoperability Matrix shows a direct jump. Our recommendation is the route through 5.2.3, as in VCF 5.2 to 9.1.1 upgrade planning. Workload domain upgrades can follow later as a Day-N procedure9.
Version floors, patch level and the forward-only rule
Without Aria products, convergence needs vCenter 8.0 Update 3a and ESX 8.0 Update 3, plus vSAN 8.0 Update 3 and NSX 4.2.1 where present8. With Aria, Aria Automation must be at 8.18.1, and Aria Operations at least at 8.18 for a 9.1.0.x target or 8.18.6 for 9.1.1.x1112. Import shares the vCenter, ESX and NSX floors3. The installer must be 9.1.1 or later13 and is redeployed, never patched, to reach 9.1.1.020010.
A vCenter with no NSX registration is upgraded to 9.1.x before convergence, while one at 8.0 Update 3a or later with NSX 4.2.1 or later converges as it is8, its NSX keeping its version until a later upgrade2. For import, a vCenter without NSX that will use a shared NSX 9.1 or have one deployed is upgraded to 9.1 first, because “NSX 9.1 does not support vCenter 8.0 Update 3a or later”. A shared NSX gives full features with NSX 9.1 and vCenter 9.1, a pinned state limited to vCenter 9.0 features with a 9.0.x vCenter, and legacy mode for NSX 4.2.x with vCenter 8.0.x3.
The newest vCenter is 9.1.1.0200, build 25901347, which fixes one CVE published as VMSA-2026-000914, and Broadcom asks for the latest available binaries in every deployment, upgrade and patch410. Our recommendation is to pick the pre-convergence vCenter build once the Interoperability Matrix pairs it with the run’s Installer and NSX builds and the change is approved.
The oldest component defines the effective VCF version of the converged instance or imported domain, and later features wait until every component reaches the target37. Upgrades move only forward in release dates, for every component in the source BoM: VCF 5.2.4 of May 27, 2026, can go to 9.1.1 of September 3, 2026, but not to 9.1.0, and a patch is a valid target only where its parent maintenance release is7. A new NSX deployed during the run is the latest version compatible with the vCenter, which KB 429205 can override3. An NSX released after a VCF minor or maintenance release blocks the upgrade to that release, so Broadcom asks for an Interoperability Matrix check first36.
Blockers to clear first
vCenter instances in Enhanced Linked Mode with existing NSX registrations cannot be converged. Linked instances without NSX can be upgraded and the link broken beforehand6. Our recommendation is to resolve linked vCenters with NSX before any other preparation.
Clusters need vSphere Lifecycle Manager images and fully automated DRS, so baseline clusters and manual or partially automated DRS are converted first6. Moving to an image changes how hosts are patched from then on. Our recommendation is to make it its own change, well before the window.
The cluster hosting the vCenter VM becomes the management domain’s primary cluster, and a vCenter VM on another vCenter’s cluster blocks convergence6. Import allows the vCenter VM on the management domain’s default cluster3. If that is the converged primary cluster, the vCenter owning a shared management cluster could be converged and the others imported, ELM permitting.
A vCenter already connected to an SDDC Manager is not supported6. Selecting one anyway makes the new deployment destroy the fleet components of the first VCF Instance and then fail15.
The vCenter’s network becomes the management network, and the new appliances go on its subnet unless a separate VCF management network is selected6. The wizard takes an IPv4 vCenter, and a dual-stack vCenter needs a JSON specification13. These configurations are supported6:
- Any supported storage type, if one datastore is shared by, and writable from, every host in the cluster. With several types, VCF picks the principal datastore in the order vSAN, NFS v3, VMFS, NFS 4.1, iSCSI and the deprecated vVols, unless a JSON specification names one.
- Stretched vSAN with at least three hosts per availability zone in 9.1 and two from 9.1.1, the witness in its own zone.
- Two-node vSAN for simple deployments, with admission control at 50% or more for CPU and memory.
- For the appliances convergence deploys, a minimum of three hosts with vSAN or two with external storage in a simple deployment, four for high availability, and 20% spare capacity, below which the installer only warns.
- A vSphere Distributed Switch at 8.0 or later, shared switches, LACP, and 1 Gbps NICs for management or vMotion.
- Supervisor clusters, with or without Avi Load Balancer, and vSphere Configuration Profiles.
- Standalone hosts and single-host clusters beside a qualifying cluster, their lifecycle left manual in the vSphere Client.
These are not supported6:
- Cisco virtual switches, and vCenter instances without a distributed switch.
- Custom vCenter client ports, and ports not aligned with VMware Ports and Protocols.
- Dynamically allocated VMkernel addresses other than NSX host TEPs.
- Several NSX Manager instances on one vCenter, and multiple VMkernel adapters on the vMotion port group.
- vSAN OSA clusters with only compression activated.
- vCenter High Availability, and partial imports of clusters.
Where the route upgrades a vCenter with a Supervisor from 8.0 Update 3 or 9.0.x to 9.1.0 or 9.1.1, Broadcom asks for the checker script from KB 455737 first, and its fix script if the result is VUM DB SCHEMA FIX REQUIRED, or the Supervisor control plane VMs and load balancers can be lost16. The KB and the 9.1.1.0100 notes list it as fixed in build 25784172 and later17. Our recommendation is to target 9.1.1.0100 or later. A 9.1.0.x or 9.1.1.0 target still needs the check.
Running the convergence
VCF Installer requires the vCenter root user property, with a 15- to 20-character ASCII password, no white space, mixing all four character classes, although vCenter 8.0 Update 3 accepts 8 to 2015. This rule and the SDDC Manager warning above are 9.1.0 Installer issue entries that the 9.1.1 notes do not list as resolved1018.
A run starts with the installer and its binaries. Aria Operations, if present, is upgraded to VCF Operations 9.1.x next, and vCenter is brought to a supported version before the installer runs1112. Afterward, the management domain inventory is synchronized in VCF Operations if a new NSX was deployed, and Aria Automation, where present, is imported in VCF Operations and upgraded to VCF Automation 9.1.x1119. Licensing, remaining components, further imports and workload domain upgrades follow8, as Figure 2 shows.
Only the converged VCF Operations instance manages fleet, lifecycle, certificates and licenses, and other Aria Operations instances become monitoring-only11. Aria Operations for Logs has no upgrade path and is replaced by a new Log Management deployment, while Aria Operations for Networks and Aria Automation Orchestrator are upgraded by hand afterward2. From 9.1.1, VCF Operations must sit in the management domain of the fleet’s first instance, and component size defaults to Small, where 9.1 defaulted high availability to Medium13.
A registered NSX comes under SDDC Manager as it is, unprepared clusters included. Otherwise SDDC Manager deploys one NSX Manager node for a simple deployment or three for high availability and prepares every eligible cluster. From an NSX Federation only the Local Manager is converted, and its NSX Manager can later be shared with workload domains6. Fleet lifecycle and SDDC lifecycle replace Aria Suite Lifecycle2. Its products are removed from it without deleting their VMs, and it stays where it manages VMware Identity Manager for VCF Automation11.
Importing a vCenter as a workload domain
An import needs SSH on vCenter and every ESX host in the inventory by FQDN. SDDC Manager must reach each NSX Manager node on port 443, and the NSX certificate must list every node FQDN and the cluster VIP in its SAN. Without NSX, the NSX install bundle matching the vCenter version must be available. A shared NSX Manager must be at or above the version of the management domain, or of every domain already sharing it, and may not be shared across VCF Instances3.
The Import a vCenter wizard, from Add workload domain in VCF Operations, asks for the vCenter and any registered NSX Manager, whose VIP FQDN must be in lower case, then for certificate thumbprints. With NSX 9.0 or later and Edge clusters, the Edge node VMs join the VCF inventory and their passwords are reset, the new ones held in SDDC Manager. A vCenter without NSX gets a new NSX Manager or joins a shared one. A single node needs an imported vCenter at 9.0 or later, three nodes are recommended, and in 9.1 the management domain’s NSX Manager can be the shared one. Prechecks with a CSV report run before Finish3, as Figure 3 shows.
In 9.1.0.x, the import activates NSX on distributed port groups, turning on the distributed firewall for every DVPG in the cluster with default rules that allow all Layer 2 and Layer 3 traffic. It can be deactivated afterward in the NSX UI or with the Transport Node Collection API. From 9.1.1 the import leaves DVPGs alone and attempts a VLAN-backed VPC configuration, and TEP-based overlay needs the SDDC Manager API with a BrownfieldOverlaySpec. When the import deploys a new NSX 9.1, a cluster with ESX 9.0.x is skipped as a version mismatch3. SDDC Manager 9.1.1 import and sync workflows put all VLAN-backed VPC clusters under one vCenter in one network span, so clusters with different VLANs or an unshared distributed switch can have connectivity issues18. Correcting the span re-prepares the hosts for NSX with host downtime, as KB 454415 warns. TEPs can be added later20, and the NSX design guide covers VLAN-backed VPC limits.
Gates, hold criteria and stopping points
Our recommendation is to clear these gates before the first change:
- Route and versions, platform architect: each vCenter’s route, source builds against floors, and the forward-only rule. Evidence: the saved Interoperability Matrix or Upgrade Planning Tool result.
- Licensing, license owner: VCF subscription capacity and a plan to register VCF Operations and the license server with the VCF Business Services console within the evaluation period21. Evidence: the entitlement and a dated registration plan.
- Topology, vSphere administrator: no ELM with NSX, no SDDC Manager connection or vCenter High Availability, the vCenter VM placed as required, nothing unsupported. Evidence: the inventory checked against the configuration tables.
- Clusters, vSphere administrator: images and fully automated DRS. Evidence: the cluster settings.
- Supervisor, vSphere administrator: a vCenter target of 9.1.1.0100 or later, or the KB 455737 check. Evidence: the planned build or the checker output.
- Accounts and network, vSphere administrator and network owner: the root password rule, the management network, an address range for the management services and five addresses for VCF Automation13, a runtime CIDR that avoids existing networks, and lower-case FQDNs with forward and reverse DNS. Evidence: the password change record, the IP plan and DNS lookups.
- Binaries, installer operator: the Installer at the planned 9.1.1 patch, binaries downloaded, and the NSX install bundle where a new NSX is deployed. Evidence: the Binary Management list.
- Aria, operations owner: Aria Operations 8.18.6 or later and Aria Automation 8.18.1 or later for 9.1.1, and a decision for every other Aria product. Evidence: versions and decisions.
- Fallback, backup owner: file-based backups of vCenter and NSX, plus Aria Operations and Supervisor backups where present, before the first upgrade and again before the run or each import. Evidence: the completed jobs.
The hold criteria follow the run:
- Pre-convergence upgrades. Hold while the route, licensing, topology, clusters, Supervisor, Aria or fallback gate lacks evidence. Stopping point: the unchanged vSphere 8 environment. Retry evidence: the missing gate evidence.
- The Installer run. Hold while the accounts and network or binaries gate lacks evidence, the backups are not refreshed, or validation shows an error. Stopping point: Validate & Deploy, before Deploy. A failed run is retried once its failed tasks are fixed13, and a component deployed with a wrong FQDN is cleaned up and redeployed first (KB 441333). Retry evidence: the missing gate evidence, refreshed backup jobs, a clean validation and, after a failure, the failed task and its fix.
- Each import. Hold while a prerequisite or precheck fails, the vCenter and NSX backups are not refreshed just before the wizard, or VLAN-backed VPC clusters under the vCenter differ in VLANs or switch. Stopping point: the wizard before Finish. Retry evidence: a clean precheck report, the refreshed backup jobs and the cluster VLAN and switch inventory.
- The next import or workload domain upgrade. Hold until the instance is licensed, backups are configured and the checks below are recorded. Stopping point: the management domain alone. Retry evidence: the license assignment, backup schedule and network checks.
Broadcom states that a VCF fleet not licensed within its 90-day evaluation must be reinstalled, and that when a vCenter’s evaluation expires its hosts disconnect and no workloads can start5.
After the run and the way back
The tasks after a convergence configure rather than validate: Review Passwords, licensing, and file-based backups for SDDC Manager and other management components13. Our recommendation is to check networking cluster by cluster, starting with any cluster an import skipped for an ESX version mismatch. With an existing NSX below 9.0, Edge cluster synchronization waits until NSX is upgraded and is then turned on in VCF Operations13.
From the first day VCF Operations orchestrates vCenter, NSX Manager and ESX lifecycle, while hosts, clusters and Edge nodes are added in vCenter, NSX Manager or the SDDC Manager cluster workflow313. Hosts join converged or imported clusters only through the vSphere Client, and the VCF Operations password management console cannot manage them until KB 388859 adds their missing root credentials to SDDC Manager6. Management services and VCF Automation VMs must stay in their resource pool and folder, or later patching, deployment and scale-out fail13.
The convergence and import pages describe no way back13. Only the 5.2.x path documents backup preparation: before the SDDC Manager upgrade, a recent SFTP backup and a snapshot of SDDC Manager and recent backups of its components22. Where a 9.1.x upgrade already lost Supervisor control plane VMs, KB 457944 reverts the vCenter upgrade and restores the Supervisor from its own backup16.
Our recommendation is these backups, which no procedure requires. They restore vCenter and NSX configuration, not NSX host preparation and its VIBs, and leave deployed appliances in place: a fallback, not a rollback.
Three points stay open. Whether the import page’s default cluster of the management domain is the converged primary cluster needs Broadcom’s confirmation. Read literally, the quoted NSX 9.1 sentence also excludes vCenter 9.x, which the shared NSX table on the same page contradicts. Our recommendation is to go by that table and the Interoperability Matrix. Whether Installer 9.1.1.0200 accepts a vCenter at 9.1.1.0200 is a matrix question too. Our recommendation is to raise the layout with Broadcom Support and to start with the licensing and Supervisor gates.
Sources
Show all 22 sources
- Paths to Building 9.1.x Environments
- Supported Components and Scenarios to Converge to VCF
- Import an Existing vCenter to Create a Workload Domain
- VMware Cloud Foundation 9.1.1.0 Release Notes
- Licensing Model
- Supported and Not Supported Configurations to Converge to VCF
- Converging Existing Virtual Infrastructure to a VCF or a vSphere Foundation Platform
- Converge a vCenter Instance, ESX Hosts, and Optionally vSAN and NSX
- Upgrading to VMware Cloud Foundation 9.1.x
- VCF Installer / SDDC Manager 9.1.1.0200 Release Notes
- Converge a vCenter Instance, ESX Hosts, VMware Aria Operations, and VMware Aria Automation, and Optionally vSAN and NSX
- Converge a vCenter Instance, ESX Hosts, VMware Aria Operations, and Optionally vSAN and NSX
- Deploy Components by Using VCF Installer to Complete the Converging to VCF Process
- vCenter 9.1.1.0200 Release Notes
- VCF Installer
- CRITICAL ADVISORY: Pre-Upgrade Verification Required for vSphere Supervisor and VKS Environments Upgrading to vCenter 9.1.0 or 9.1.1
- vCenter 9.1.1.0100 Release Notes
- VCF Installer / SDDC Manager 9.1.1.0 Release Notes
- Converge a vCenter Instance, ESX Hosts, VMware Aria Automation, and Optionally vSAN and NSX
- NSX
- Registering VCF Operations and a License Server with the VCF Business Services Console
- Upgrade to SDDC Manager 9.1