Multi-site design in VCF 9.1: fleets, instances, NSX Federation and site loss

Putting a VMware Cloud Foundation 9.1 fleet on two sites means choosing between one VCF Instance stretched across two availability zones, a second instance in another region, or both, and deciding how the management plane comes back after a site loss. The baseline here is VCF 9.1.1 with the October 12, 2026, patches. The fleet-level components, including VCF Operations and VCF Automation, run in the management domain of the first VCF Instance1, so the layout determines which of them keep running when that site goes dark and which someone has to restore elsewhere.

Our recommendation is to start with one stretched instance wherever the two data centers meet the vSAN stretched cluster limits, and to add a second instance in another region only when continuity planning names an event that takes both zones, with the blueprint’s 4-hour recovery target for VCF Operations recorded against the business requirement. Three choices then come before the second instance is deployed, and before VCF Operations and VCF Automation go onto their final network: the management network model, the single sign-on model and where software depots run.

Four designs and what each survives

Broadcom’s fleet deployment models page describes four designs and maps each to blueprints2. The basic design keeps the fleet in one availability zone or region. It protects against single host or storage device failures, and a zone or region failure can take the whole fleet down. Its two blueprints, minimal footprint and single site, stay in one zone, and the minimal one tolerates only the failure of one ESX host or one network path34.

Site high availability runs one fleet across two availability zones2. Its blueprint, multiple sites in a single region, is a single instance with a stretched cluster between the sites and tolerates the loss of one availability zone5. Against site-wide events, the disaster recovery design adds a second instance in a separate availability zone or region and uses VMware Live Recovery for failover and failback2. Its blueprint, multiple sites across multiple regions, lists no zone among the failures it tolerates and points to the backup and fleet disaster recovery blueprints for recovery6. The fourth design combines zone-level high availability with cross-region recovery2. Its blueprint can recover from one site loss within the region if both sites have the external connectivity and compute for every recovered workload7.

On the same page2, the basic design simplifies the architecture but provides no site-level high availability or disaster recovery. Site high availability fails over automatically between zones, restarting VMs in the surviving zone, near-instantaneously for protected workloads and with no data loss from synchronous storage replication. It needs low-latency, high-bandwidth links and IP addresses stretched between the zones, an advanced network setup that can increase operational complexity. The disaster recovery design typically fails over manually or semi-automatically and more slowly, may lose data depending on its RPO, and needs significant investment in a secondary site’s hardware, software and network connectivity. The combined design shifts resources automatically to healthy nodes inside the region and fails over to a secondary site for major disruptions, with the same RPO-dependent data loss. It needs both redundant infrastructure and a secondary site, with higher hardware and licensing costs, and stretched IP addresses between its zones. Figure 1 sets the four side by side.

Protects against
Failover and data loss
Cost and prerequisites
Basic
Protects against: Single host or storage device failures. A zone or region failure can stop the whole fleet
Failover and data loss: No site-level high availability or disaster recovery
Cost and prerequisites: One zone or region, which simplifies the architecture
Site high availability
Protects against: Loss of one availability zone. An outage of both zones still needs a separate disaster recovery mechanism
Failover and data loss: Automated between zones, near-instantaneous for protected workloads. No data loss from synchronous storage replication
Cost and prerequisites: Low-latency, high-bandwidth links. IP addresses stretched between zones, an advanced network setup that can increase operational complexity
Disaster recovery
Protects against: Site-wide failures
Failover and data loss: Typically manual or semi-automated, slower than high availability. Some data loss possible, depending on the RPO
Cost and prerequisites: Significant investment in a secondary site: hardware, software and network connectivity
Fault domains and disaster recovery
Protects against: Loss of one availability zone inside the region, and site-wide disasters
Failover and data loss: Resources shifted automatically to healthy nodes in the cluster. Failover to a secondary site for major disruptions, with some data loss possible depending on the RPO
Cost and prerequisites: Both redundant infrastructure and a secondary site, with higher hardware and licensing costs. Stretched IP addresses between zones
Figure 1. The four VCF 9.1 fleet deployment designs compared on protection, recovery and cost.

Stretching one instance across two zones

A stretched cluster spans at most two zones. On vSAN they need at least 10 Gbps and a round-trip latency under 5 ms, with the witness in a third, independent fault domain, and with array-based stretched storage the vendor defines bandwidth and latency. The management domain has to be stretched before any workload domain cluster can be. A stretched vSAN cluster takes six hosts, or eight for the first management cluster in the highly available model. Admission control is raised to “half of the ESX hosts” so that one zone can run every VM, and hosts added to the default management cluster go in pairs, one per zone8. The fabric design applies the 5 ms limit to every host of a stretched cluster9. The stretched cluster article sets out the order in which clusters are stretched.

For Fibre Channel or NFS, KB 417356 says Broadcom does not test vSphere Metro Storage Cluster solutions itself and asks the storage vendor to confirm testing with VCF 9.x before purchase. Its first management cluster supports only stretching all Layer 2 networks.

Once per fleet, once per instance

The first instance’s VCF management services cluster runs fleet-level components next to instance-level ones, while each additional instance runs one with instance-level components for that instance only7. The software depot splits the same way: a fleet-level depot on the first instance, plus an optional instance-level depot where latency between the first instance’s depot and another instance exceeds 150 ms10. Each instance keeps its own SDDC Manager, vCenter and NSX Manager1 and its own cloud proxy11. Latency between the instances of a fleet should stay under 300 ms, the figure given for VCF Operations to its managed entities and for NSX Federation to a managed NSX Manager9. KB 412252 calls these fabric figures a critical design recommendation, not a software limit.

One license server can license a whole fleet, but it cannot be shared between fleets. Where a vCenter instance has unreliable connectivity and latency above 300 ms, the licensing guide allows a license server in that vCenter instance. Each license server needs its own license allocation and a connection to VCF Operations at least once every 180 days for a license refresh, and a host can be licensed only if its vCenter reaches the license server12. The identity broker models trade resource footprint against blast radius13 and are compared in the identity article.

NSX Federation and the fleet management network

NSX Federation adds Global Managers above the instances’ Local Managers, one management plane that can extend segments and security groups across workload domains in the same or different VCF Instances14. The multi-region blueprints select the shared VLAN network model for the management components and do not say how IP mobility is provided67. The design library’s two-region network model answers that with Federation11.

In that model, VCF management services stay on a dedicated VLAN. VCF Operations, VCF Automation, VCF Operations for networks and the license server go on an NSX overlay segment that Federation stretches to the second instance, which gives VCF Operations IP mobility when it fails over between regions. VCF Automation needs no IP mobility when restored in a second region, but the same segment spares a DNS change for its VIPs. The Edge cluster, gateways and segment are created by hand before those components are deployed, and Broadcom recommends the VCF Installer’s deferred deployment option for them. For disaster recovery the management services VLAN does not have to be stretched between instances. The second region either gets a separate, routable network, with VIP DNS updates during a restore, or shares one network stretched between regions11.

The cross-instance network is failed over and back by hand from the standby Global Manager11. The standby Global Manager model costs an additional cluster with manual failover14 and places it in the second VCF Instance so that the Global Manager can be recovered there if the first instance fails15. After an unplanned loss the standby is made active with a forced failover, configuration can be lost if synchronization had been failing, and workload VMs are recovered separately16. A location with stretched networks must be within 150 ms of the Global Manager17. VCF does not manage the lifecycle of Global Managers federating two VCF Instances, and they have to be upgraded, standby and active, before any VCF Instance or NSX Local Manager18. RTEPs, stretched gateways and Federation’s limits are covered in the NSX Federation design article.

Fleet network placement and Global Manager recoveryRegion A contains the first VCF Instance. Its management domain hosts VCF Operations, VCF Automation, VCF Operations for networks and the license server on an NSX overlay segment. Federation stretches that segment to the second instance in region B, the fleet recovery site. The active Global Manager is in the first instance and the standby is in the second. After an unplanned loss, forced failover makes the standby active. Configuration may be lost if synchronization had been failing. Cross-instance network failover and failback are manual from the standby. Workload VMs are recovered separately.First VCF InstanceRegion ASecond VCF InstanceRegion BFleet recovery siteManagement domainNSX overlay segmentVCF OperationsVCF AutomationVCF Operationsfor networksLicense serverStretched overlaysegmentFederationstretchesActiveGlobal ManagerStandbyGlobal ManagerManualCross-instance networkfailover and failbackAfter unplanned lossForced failoverActiveGlobal ManagerPossible configurationloss if synchronizationhad been failingWorkload VMs: separate recovery Fleet network placement and Global Manager recoveryRegion A contains the first VCF Instance. Its management domain hosts VCF Operations, VCF Automation, VCF Operations for networks and the license server on an NSX overlay segment. Federation stretches that segment to the second instance in region B, the fleet recovery site. The active Global Manager is in the first instance and the standby is in the second. After an unplanned loss, forced failover makes the standby active. Configuration may be lost if synchronization had been failing. Cross-instance network failover and failback are manual from the standby. Workload VMs are recovered separately.First VCF InstanceRegion AManagement domainNSX overlay segmentVCF OperationsVCF AutomationVCF Operationsfor networksLicense serverActiveGlobal ManagerFederation stretchesthe overlaySecond VCF InstanceRegion B: fleet recovery siteStretched overlaysegmentStandbyGlobal ManagerUnplanned lossForced failoverManualCross-instancenetwork failoverand failbackActiveGlobal ManagerPossible loss ofconfiguration ifsynchronizationhad been failingWorkload VMs: separate recovery
Figure 2. The two-region network model stretches an NSX overlay segment with Federation. Global Manager recovery and cross-instance network failover are manual.

What survives the loss of a site

VCF Operations can go beyond automated zone failover with Continuous Availability, which needs a second VCF Instance in the other zone: node pairs across two zones and a witness in a third location, within 10 ms between nodes (peaks to 20 ms over 20-second intervals) and 30 ms to the witness. Its replica and witness nodes are deployed by hand, and if both zones fail the whole deployment is restored from backup19.

The fleet disaster recovery blueprint covers the loss of a whole VCF Instance or site, with recovery typically outside metro radius, and the method depends on the fleet component20. VCF Operations and VCF Operations for networks are replicated under a Protection and Recovery recovery plan or restored from image-based backup, and both methods require IP mobility. For VCF Operations, Continuous Availability between sites can replace them if its latency requirements are met. VCF Automation is deployed new at the recovery site and restored from backup, with no IP mobility needed. The identity broker, fleet lifecycle, software depot, Salt RaaS and log management are restored onto the VCF management services instance already running at the recovery site. A license server outage leaves running workloads and management alone until the usage report is due or a new license assignment is needed, and VCF Operations restores the assignments to a newly deployed license server20. Cloud proxies stay on each instance’s VM management network and are not failed over11. Figure 3 summarizes the paths.

A broker can be restored to another existing VCF Instance in the same realm, or to one without VCF single sign-on, never into a different realm, and local accounts and the VCF SSO emergency access client keep working meanwhile21. The cross-instance model supports that restore22. Under the fleet-wide model the broker lives on the primary instance, which has to be restored instead23, and the single-instance model would cross realms24.

Recovery at the other site
Conditions
VCF Operations and VCF Operations for networks
Recovery at the other site: Replicated under a Protection and Recovery recovery plan, or restored from image-based backup
Conditions: Both need IP mobility. For VCF Operations, Continuous Availability between sites if its latency requirements are met
VCF Automation
Recovery at the other site: Deployed new at the recovery site and restored from backup
Conditions: No IP mobility needed
Identity broker, fleet lifecycle, software depot, Salt RaaS, log management
Recovery at the other site: Restored onto the VCF management services already running there
Conditions: Broker and depot only if no other instance of them is deployed there. Broker only within its SSO realm or onto an instance without VCF single sign-on
License server
Recovery at the other site: New license server deployed, VCF Operations restores the assignments
Conditions: Running workloads unaffected until the usage report is due or a new assignment is needed
Cloud proxies
Recovery at the other site: Not failed over
Conditions: Stay on each instance’s VM management network
Figure 3. How fleet components come back at another site after a VCF 9.1 instance or site failure.

The blueprint’s design elements require Protection and Recovery in both the protected and the recovery VCF Instance, vSphere Replication with all management components in one cluster, and a 15-minute RPO with three point-in-time copies over 24 hours on the management VM policies. Recovery of VCF Operations and VCF Operations for networks is automated within an RTO of 4 hours or less, and VCF Automation, restored from backup, has no stated RTO. Guest quiescing stays off, so the replicas are crash-consistent. Each instance needs a backup location in VCF Operations, and the primary site’s backups must reach the recovery site’s SFTP server, the same server or a replica. Protected components use the DNS and NTP servers of all instances, and Protection and Recovery is upgraded with its own tools, outside VCF Operations25.

Which design to build

Site high availability stays an availability design that needs separate disaster recovery for an outage of both zones2. Our recommendation is to start with it where two data centers are within the stretched cluster’s latency limit and the risk to cover is the loss of one of them.

Only a second instance outside the stretched pair survives an event that takes both zones, and its recovery is typically started by people. Our recommendation is the disaster recovery design on its own when the sites are too far apart to stretch, with workload targets set in the protection and recovery design.

Two placement decisions follow in the recovery region. The blueprint restores the identity broker and the software depot there only if no other instance of that component runs on the recovery site’s VCF management services, which hold one of each20. In our reading, a broker of its own in the recovery instance blocks the broker restore, and an instance-level depot blocks the depot restore. Leaving that depot out has a cost where latency to the fleet depot exceeds 150 ms, the case it exists for10: binaries then cross the slow link. Our recommendation is the cross-instance model, with the recovery instance in the broker’s realm and no broker of its own, and Broadcom’s written confirmation of that restore before the recovery instance is deployed.

Evidence and hold points

Our recommendation is to have this evidence before sign-off.

  • Continuity requirement. Owner: business continuity owner. Evidence: the failure events to survive (zone, site or region), the accepted management-plane RPO and RTO against 15 minutes and 4 hours, and the chosen design.
  • Links. Owner: network engineer. Evidence: measured round-trip times and bandwidth, at least 10 Gbps and under 5 ms between zones, a third fault domain for the witness, under 300 ms between instances, 150 ms or less from the Global Manager to a location with stretched networks, and the Continuous Availability limits where used.
  • Stretched capacity. Owner: virtualization architect. Evidence: host counts per zone, admission control at half, the management domain stretched first, and for Fibre Channel or NFS the vendor’s written VCF 9.x test confirmation.
  • Management network. Owner: network architect. Evidence: the network model recorded before VCF Operations and VCF Automation are deployed, the Edge cluster, gateways and segment in place, and the management services VLAN option with its DNS runbook.
  • Identity and depots. Owner: identity architect. Evidence: the SSO model and realm of every instance, the broker and depot placement in the recovery instance, and Broadcom’s written confirmation of the broker restore.
  • Recovery prerequisites. Owner: platform operations lead. Evidence: Protection and Recovery in both instances, management VM policies at a 15-minute RPO with three copies, a backup location per instance, primary backups on the recovery SFTP server, and DNS and NTP servers of all instances on protected components.
  • Standby Global Manager. Owner: NSX engineer. Evidence: the standby cluster deployed in the second instance and the Global Manager upgrade order in the lifecycle runbook.
  • Recovery test. Owner: disaster recovery owner. Evidence: VCF Operations and VCF Operations for networks recovered within 4 hours, VCF Automation and the management services components restored, the cross-instance network failed over from the standby Global Manager, and sign-in with local accounts while the broker is down.

Our recommendation is to hold at each step below until its evidence exists.

  • Design sign-off. Hold while the continuity requirement is unwritten. Stopping point: the basic design. Retry with the failure events and targets approved.
  • Stretching a cluster. Hold while a link misses its limit, the witness lacks a third fault domain, a zone lacks hosts, admission control is below half, a workload domain cluster comes before the management domain8, or the array vendor has not confirmed testing as KB 417356 asks. Stopping point: the cluster unstretched in the first zone. Retry with passing measurements, the witness in a third fault domain, the full host count, admission control at half, the management domain stretched first and the vendor’s letter.
  • VCF Operations and VCF Automation deployment. Hold while the network model, the VLAN option or its DNS runbook is missing. Stopping point: the management domain without deferred components. Retry with the model recorded, the VLAN option and its DNS runbook approved, and the Edge cluster, gateways and segment in place.
  • Second instance. Hold while latency to the first instance is 300 ms or more, or the SSO model, realm, depot placement or Broadcom’s written confirmation of the broker restore is missing. Stopping point: the first instance in production on its final networks. Retry with the measurement, the identity and depot evidence and the confirmation.
  • Stretched segment. Hold while the Global Manager is more than 150 ms from the second location, the standby Global Manager is not deployed in the second instance or its upgrade order is missing151718. Stopping point: the second instance’s Edge cluster deployed, with no gateway extended to it. Retry with the measurement, the standby cluster deployed and the runbook.
  • Relying on fleet recovery. Hold while a recovery prerequisite is missing, Continuous Availability misses its latency limits where used, or the test exceeds 4 hours, skips the cross-instance network failover or fails local-account sign-in. Stopping point: replication and backups running, no failover relied on. Retry with the configuration evidence of every prerequisite, the latency measurements and a test report covering every test item.

Three points stay open. The fabric design sets 300 ms between instances, Federation to managed NSX Managers included9, while the NSX location page allows 500 ms without stretched networks17, so our recommendation is to plan for 300 ms, and 150 ms where segments are stretched. In our reading, the blueprints’ own SSO choices do not fit the broker restore: the multi-region blueprint selects the fleet-wide model6, which ties the broker to a restore of the first instance23, and the combined blueprint selects the single-instance model7, with a broker in every instance. Until Broadcom confirms the cross-instance restore, our recommendation is to plan for the restore the chosen model allows and keep local-account access in the runbook. KB 417356 accepts 10 ms between hosts of an array-based stretched cluster where the fabric design asks for 5 ms, so our recommendation is 5 ms for those clusters too.

Sources

Show all 25 sources
  1. VCF Taxonomy
  2. VCF Fleet Deployment Models
  3. VCF Fleet in a Single Site with Minimal Footprint
  4. VCF Fleet in a Single Site
  5. VCF Fleet with Multiple Sites in a Single Region
  6. VCF Fleet with Multiple Sites Across Multiple Regions
  7. VCF Fleet with Multiple Sites in a Single Region plus Additional Region(s)
  8. Stretched vSphere Cluster Model
  9. Physical Data Center Network Design
  10. Binary Management for VMware Cloud Foundation
  11. VCF Management Dedicated VLAN and NSX Stretched Overlay Segment Network Model
  12. License Server Overview
  13. Identity Broker Models
  14. NSX Manager and Control Plane Models
  15. High Availability with Standby NSX Global Manager Model
  16. Disaster Recovery for Global Manager
  17. Add a Location
  18. Upgrading NSX Global Manager Nodes in a Federated Environment
  19. Continuous Availability VCF Operations Model
  20. VCF Fleet Disaster Recovery
  21. VCF Single Sign-On Detailed Design
  22. Cross VCF Instance Single Sign-On Model
  23. VCF Fleet-Wide Single Sign-On Model
  24. Single VCF Instance Single Sign-On Model
  25. Design Elements for VCF Fleet Disaster Recovery