In VMware Cloud Foundation 9.1, the default management domain cluster must be stretched before any workload domain cluster can be1. The baseline here is VCF 9.1.1 with the October 12, 2026, patches. Stretched, the management cluster needs a witness appliance in a third site and six hosts in the Simple deployment model, or eight in the Highly Available model23.

Our recommendation is to stretch only where the links meet the strictest published figures: under 5 ms between the data sites, with bandwidth sized from write load and 10 Gbps as the floor, and under 150 ms to the witness, or under 100 ms at 11 to 15 hosts per site. Our recommendation is also to budget the management domain’s extra hosts and the witness site with the first stretched workload cluster, not as a later management project.

A stretched cluster is one vSAN cluster whose hosts sit in two availability zones: two data centers at metro distance or two data halls in one large facility. vSAN replicates synchronously between them, so latency, more than distance, limits how far apart they can be2. Two zones alone do not call for a second workload domain (see the workload domain decision article).

Host counts and what blocks a stretch

Stretched vSAN HCI clusters other than the management domain’s first cluster, workload domain clusters included, need at least six hosts, three per zone, with the same number in both zones12. At three per site, vSAN does not rebuild objects automatically after a local failure2. The VCF design pages set no maximum per zone, while the vSAN Stretched Cluster Guide for VCF 9.1 gives a product maximum of 40 data hosts, 20 per site, plus the witness, and suggests 32 or fewer where capacity or VM counts are high, which works better with vSAN’s host component limits and with the rack and switching topology of each site4.

A stretched vSAN storage cluster needs four hosts per zone, and seven per zone are recommended so that RAID-6 can rebuild after a host is lost5. A vSAN compute-only cluster can run as two nodes, one in each zone, without a witness1.

Minimum hosts
Conditions
Management domain
Minimum hosts: 6 in the Simple model, 8 in the Highly Available model
Conditions: Stretched before any workload domain cluster
Other vSAN HCI clusters
Minimum hosts: 6, three per site
Conditions: Equal host counts in both zones, and no automatic rebuild after a local failure at three per site
vSAN storage cluster
Minimum hosts: 4 per zone
Conditions: 7 per zone recommended, so RAID-6 can rebuild after a host is lost
vSAN compute-only cluster
Minimum hosts: Can run as 2, one per zone
Conditions: No witness
Figure 1. Minimum host counts for each kind of stretched cluster in VCF 9.1.

A cluster cannot be stretched if it shares a vSAN storage policy with another cluster, contains DPU-backed hosts, places hosts on different Layer 3 networks within one zone, is an ESA or storage cluster with Global Deduplication enabled, or has vSphere Supervisor enabled16.

Because DPUs and the network layout are fixed at purchase, our recommendation is to give a cluster that may be stretched later hosts without DPUs and one Layer 3 network per zone, so no rack-routed zone, and to leave the day-2 Global Deduplication setting off on it.

The witness site

The witness stores only metadata and breaks the tie when the data sites lose contact. It cannot run VMs. One witness serves one stretched cluster, and only two-node clusters may share a witness7. VCF requires the appliance in a location not co-located with the hosts of either zone and without logical or physical dependency on either of them, and the appliance has to match the cluster’s vSAN architecture2: the ESA appliance for ESA and vSAN storage clusters, the OSA appliance for OSA8. The witness runs the same ESX version as the cluster’s hosts8: the 9.1.1 GA Bill of Materials of September 3, 2026, lists separate ESA and OSA witness builds at 9.1.1.0 like ESX9, and the vSAN 9.1.1.0100 patch of October 12, 2026, brings both appliances to 9.1.1.010010.

The Stretched Cluster Guide lets the appliance run on another stretched cluster only if that cluster does not sit in the same sites4. Our recommendation is to read the dependency rule strictly: give the witness a third site with its own network and power, and keep it off any host cluster or network that runs through either zone.

The appliance comes in sizes based on the deployment7. The design sets no minimum bandwidth to the witness, because the volume grows with the VMs and components that stretched policies protect2. The Stretched Cluster Guide plans about 2 Mbps for every 1,000 components4. Configure the witness identity like any ESX host and enable vSphere Lifecycle Manager images on it2, but do not snapshot or back it up, and replace it if it fails11. A failed witness leaves objects noncompliant but accessible7.

vSAN accepts a physical host as witness7, while the VCF design specifies the appliance2. At upgrade time a physical witness is upgraded by hand before the cluster’s hosts, and a virtual one inside the cluster upgrade workflow12.

Networks across three sites

Between the data sites the design allows at most 5 ms round trip, or 2.5 ms one way, and requires at least 10GbE2. The stretched vSAN storage model and the Stretched Cluster Guide allow 200 ms round trip, or 100 ms one way24. The VCF fabric design requires under 150 ms from the hosts of a stretched cluster to the witness13. The vSAN bandwidth sizing guide keeps 200 ms up to 10 hosts per site, lowers it to 100 ms for 11 to 15 hosts per site and gives no figure above 1514. Both guides treat 10 Gbps as a minimum, and the sizing guide calculates the link from write bandwidth414. KB 412252 calls the fabric design’s latency figures a critical design recommendation, not a software limit: installation proceeds above them.

Layer 3 is recommended between all three sites to keep spanning tree from steering traffic over an unwanted link, and the gateways should be highly available enough to survive the loss of a whole zone2. vSAN itself supports Layer 2 and Layer 3 between the data sites and needs Layer 3 to the witness, and the VM and vMotion networks only have to connect the two data sites15.

In the stretched vSphere cluster model, ESX management, vMotion, vSAN and host TEP networks are unique to each zone, while VM management and VCF management are shared across the zones. Every vSAN VMkernel adapter overrides the default gateway, and the vSAN networks of the two zones must route to each other. Zone 2 gets its own uplink profile, host TEP VLAN and NSX sub-transport node profile, and the design recommends static host TEP pools, one per zone with its own subnet and gateway3. SDDC Manager creates that sub-transport node profile during the stretch, for zone 2 hosts commissioned from their own network pool with the same vmnic-to-distributed-switch mapping as zone 16.

Witness traffic separation is recommended, so that vSAN data can keep its own VLAN and MTU. The design also recommends that the witness send witness traffic over vmk0, its management interface, at the same MTU as the host management interfaces, 1500 by default. The ESX management networks of both zones must be routed to the witness, and so must the VM management network if it is configured. Without separation, witness traffic uses the vSAN data network, and the vSAN data VLAN must be routed to the witness network2.

Three-site stretched vSAN topologyOne stretched vSAN cluster spans two availability zones with equal host counts. A separate third site holds one architecture-matched ESA or OSA witness appliance per cluster. Direct witness links reach both data sites. With the recommended witness traffic separation shown, witness traffic uses vmk0 and routes to both zones’ ESX management networks. Witness links require Layer 3. Their round-trip limit is under 150 milliseconds in the fabric design and 200 milliseconds in the vSAN guides, or under 100 milliseconds with 11 to 15 hosts per site in the bandwidth sizing guide. Synchronous replication between the data sites requires at least 10GbE and at most 5 milliseconds round trip. Layer 3 is recommended between all three sites. ESX management, vMotion, vSAN and host TEP networks are unique to each zone. VM management and VCF management networks are shared across both zones.Third site: witnessOne witness per clusterArchitecture-matchedESA or OSA applianceWitness round trip< 150 ms (fabric design)≤ 200 ms (vSAN guides)< 100 ms at 11 to 15 hostsper site (sizing guide)Layer 3 requiredRecommended separationWitness traffic on vmk0Routes to both zones’ESX management networksAvailability zone 1Data siteEqual host countsAvailability zone 2Data siteEqual host countsSynchronous vSAN replication≤ 5 ms round trip · ≥ 10GbEOne stretched vSAN clusterLayer 3 recommended between all three sitesUnique per zoneESX management · vMotionvSAN · host TEPShared across both zonesVM managementVCF management Three-site stretched vSAN topologyOne stretched vSAN cluster spans two availability zones with equal host counts. A separate third site holds one architecture-matched ESA or OSA witness appliance per cluster. Direct witness links reach both data sites. With the recommended witness traffic separation shown, witness traffic uses vmk0 and routes to both zones’ ESX management networks. Witness links require Layer 3. Their round-trip limit is under 150 milliseconds in the fabric design and 200 milliseconds in the vSAN guides, or under 100 milliseconds with 11 to 15 hosts per site in the bandwidth sizing guide. Synchronous replication between the data sites requires at least 10GbE and at most 5 milliseconds round trip. Layer 3 is recommended between all three sites. ESX management, vMotion, vSAN and host TEP networks are unique to each zone. VM management and VCF management networks are shared across both zones.Third site: witnessOne witness per clusterArchitecture-matchedESA or OSA applianceWitness round trip< 150 ms (fabric design)≤ 200 ms (vSAN guides)< 100 ms at 11 to 15 hostsper site (sizing guide)Layer 3 requiredRecommended separationWitness traffic on vmk0Routes to both zones’ESX management networksZone 1Data siteEqual hostcountsZone 2Data siteEqual hostcountsSynchronous vSAN replication≤ 5 ms round trip · ≥ 10GbEOne stretched vSAN clusterTwo availability zonesLayer 3 recommendedbetween all three sitesUnique per zoneESX management · vMotionvSAN · host TEPShared across both zonesVM managementVCF management
Figure 2. Three-site stretched vSAN topology, link requirements and network scope, with recommended witness traffic separation.

NSX Edges across the zones

The NSX Edge design library has two models for dual availability zones. In the Edge node HA model, Edge nodes never move between zones, and each zone can use separate VLANs for Edge uplink traffic, improving failure isolation. Failover is fast and automatic in routing options A, B and C and manual in option D. The options differ on whether asymmetric traffic between the zones is acceptable, which usually depends on whether a stateful device sits in the path, and option A is the asymmetric one. Latency limits follow the vSphere topology: 5 ms round trip on a stretched vSAN cluster, up to 10 ms when each zone has independent vSphere clusters16.

The vSphere HA recovery model places at least two Edge nodes on the stretched vSAN cluster and lets them move. Its Edge uplink, management and TEP VLANs must be stretched across both zones. A should rule keeps the nodes on the primary zone’s hosts, and Best Effort Restart must stay off because it needs must rules. After a complete zone outage, recovery depends on vSphere HA, which may take several minutes17. A stretched cluster that hosts an Edge cluster sets isEdgeClusterConfiguredForMultiAZ to true in the stretch specification6.

Our recommendation is to choose Edge mobility only where the Edge VLANs can be stretched and north-south traffic can wait minutes after a zone loss. Otherwise use the Edge node HA model: option B or C with a stateful device between the zones, option A without one.

Storage policies for two sites

When it stretches a cluster, SDDC Manager switches the site disaster tolerance of the default datastore policy from none to site mirroring, affecting every VM that uses that policy, so a VM that should keep its current protection needs a different policy first6.

On OSA, the design sets the default policy to site mirroring with one failure to tolerate on RAID-1 and recommends Force Provisioning. On ESA, 9.1 turns Auto-RAID on by default for new clusters, and on a cluster still using Auto-Policy the default policy is adapted to the host count and topology during the conversion. Force Provisioning no longer applies in a stretched cluster that uses Auto-RAID2. Clusters upgraded to 9.1 keep their previous policies, which may be Auto-Policy’s. Broadcom’s vSAN FAQ says to always use Auto-RAID on 9.1 and prefers moving all objects and the default datastore policy to the vSAN ESA Auto-RAID Policy over enabling Apply Auto-RAID to all objects18.

Auto-RAID mirrors across the sites and adds, inside each site, RAID-5 (2+1) from 3+3+1 hosts or RAID-6 (4+2), tolerating two failures per site, from 6+6+1, at 3x protection overhead in both cases. Without Auto-RAID, the table adds RAID-1 inside each site at 4x from 3+3+1, and RAID-5 (4+1), tolerating one failure per site, at 2.5x from 6+6+119.

At six hosts per site, the choice between Auto-RAID’s RAID-6 (4+2) and a self-managed RAID-5 (4+1) policy depends on rebuilds. RAID-6 (4+2) occupies all six hosts of a site, leaving nowhere to rebuild after a host loss, the reason the storage cluster design gives for a seventh host per zone5. RAID-5 (4+1) leaves a host free at 2.5x but tolerates one failure per site instead of two. A self-managed RAID-5 (4+1) policy departs from the FAQ’s Auto-RAID advice and only takes effect on a cluster where Apply Auto-RAID to all objects is not enabled, because that setting overrides self-managed policies. Turning the setting off may reconfigure objects back to their old policies18. Where a failed host may take days to replace, our recommendation is a seventh host per zone under Auto-RAID, and RAID-5 (4+1) only on a cluster that never enabled that setting, with the departure from Broadcom’s advice recorded.

Reserved Capacity is not supported on stretched clusters, so the design leaves it off and asks for slack space to be calculated by hand or with the vSAN sizer2.

HA, DRS and VM placement

For a zone loss, the design recommends vSphere HA admission control that reserves 50% of the CPU and memory of the whole stretched cluster, enough to restart a failed zone’s VMs in the other2. In the cluster model’s example of eight hosts, the resources of only four hosts are available for use3. For expansion, the procedure recommends equal numbers of new hosts per zone, each from its zone’s network pool, then setting Host failures cluster tolerates to the number of hosts in availability zone 1. New hosts may also need static routes to the witness’s vSAN network20.

VCF requires one host group per zone and recommends a VM group and a should-run VM-Host rule for each zone. The VM groups and rules are created by hand3, and the design asks for them to work in conjunction with the storage policies2. On the vSAN side, DRS must be enabled and HA datastore heartbeats disabled, and HA rule settings should respect the VM-Host rules during failover11. VCF management services VMs are the exception: manually created zone affinity rules do not apply to them, and they rely on Cluster API node anti-affinity for placement1.

When the link or a zone fails

One data site is designated preferred. If the link between the data sites fails, vSAN normally continues on the preferred site, unless that site is resyncing or has another issue7. Under the vSphere HA recovery model, our recommendation is to make the zone that holds the Edge nodes the preferred site, which lowers the chance that a link failure leaves the running storage and the north-south path in different zones.

vSAN 9.1 adds a site maintenance mode for stretched clusters and promotes the surviving data site and the witness automatically when a site fails21. A data site and the witness lost at the same time leave objects without quorum and unavailable, and the Stretched Cluster Guide refers recovery to Broadcom Global Support. Its manual site takeover covers one case: a data site already in site maintenance mode is recovered after the other data site or the witness site fails permanently4. When a failed site comes back, bring its hosts online together, ideally within 10 minutes, so that vSAN does not resynchronize large amounts of data. VMs created while a site is down stay noncompliant until it rejoins. Before vSAN 9.1 they were force provisioned with no failure tolerance, and from 9.1 they are created to the lower failures to tolerate that the policy specifies22.

vSAN
Design and operations
Witness lost
vSAN: Objects become noncompliant and stay accessible
Design and operations: A witness dedicated to the cluster, never snapshotted or backed up. Replace the witness host
Link between zones lost
vSAN: Normally continues on the preferred site, unless it is resyncing or has another issue
Design and operations: Should-run rules per zone, respected by HA during failover
Data site and witness lost together
vSAN: Objects without quorum and unavailable
Design and operations: Data recovery with Broadcom Global Support. Manual site takeover only recovers a site already in site maintenance mode when the other data site or the witness then fails permanently
Zone lost
vSAN: Promotes the surviving data site and the witness automatically in 9.1
Design and operations: 50% of CPU and memory reserved for HA restarts. Edge failover by Edge node HA (manual in routing option D), or in the recovery model by vSphere HA, which may take several minutes
VMs created during the outage, and the zone’s return
vSAN: VMs created during the outage meet the policy’s lower failures to tolerate (9.1) and stay noncompliant until the zone rejoins
Design and operations: Hosts brought back together, ideally within 10 minutes, to limit resynchronization
Figure 3. Failure events in a VCF 9.1 stretched cluster, with what vSAN does and what the design and operating guidance provide.

Evidence and hold points

Our recommendation is to have this evidence before a cluster is stretched.

  • Links. Owner: network engineer. Evidence: round-trip times measured against the figures in our recommendation above, with Broadcom’s written figure above 15 hosts per site, bandwidth calculated from write load with about 2 Mbps per 1,000 components to the witness, and a gateway failover test showing the Layer 3 gateways survive a zone loss.
  • Witness. Owner: virtualization architect. Evidence: the third site’s own power and network, an appliance matching the cluster’s architecture and ESX version, and route tables or ping tests showing witness traffic routed to both zones’ management networks.
  • Hosts and blockers. Owner: virtualization architect. Evidence: the management domain already stretched, equal host counts at or above Figure 1, no DPU-backed hosts, one Layer 3 network per zone, no shared storage policy, Global Deduplication and vSphere Supervisor off, and for a cluster meant to carry a Supervisor, Broadcom’s written confirmation that it can be enabled after the stretch.
  • Zone 2 networking. Owner: NSX engineer. Evidence: the zone 2 network pool, uplink profile, host TEP VLAN and TEP pool, the same vmnic mapping as zone 1, the recorded Edge model decision, and for the recovery model the stretched Edge VLANs configured on the physical network.
  • Policies. Owner: storage administrator. Evidence: VMs that must keep their protection moved off the default policy, the target policy per cluster, and slack space sized in the vSAN sizer.
  • HA and DRS. Owner: virtualization administrator. Evidence: admission control at 50%, host groups, VM groups and should-run rules per zone, DRS on, datastore heartbeats off, and the preferred site set in the vSAN fault domain configuration.
  • Operations. Owner: platform operations lead. Evidence: a runbook for witness replacement, site maintenance mode and bringing a returning zone’s hosts back together, and a site maintenance test.

Our recommendation is to hold at two points.

  • Stretching the cluster. Hold while any evidence listed under links, witness, hosts and blockers, zone 2 networking or policies is missing or fails. Stopping point: the cluster unstretched in zone 1, with zone 2 hosts commissioned but not added. Retry with the failed item’s listed evidence, such as new measurements, the gateway failover test, the Edge model decision with stretched Edge VLANs, the target policy and slack-space sizing, or the Supervisor confirmation.
  • Production workloads. Hold while any HA and DRS or operations evidence is missing or fails. Stopping point: the stretched cluster running only management or test VMs. Retry with the exported HA and DRS settings, the vSAN fault domain configuration showing the preferred site, the runbook and the site maintenance test report.

Some points stay open. The witness figures disagree and stop at 15 hosts per site241314, so our recommendation is the stricter figure at every size and Broadcom’s written figure above 15 hosts per site. On an ESA cluster with Auto-RAID, the design asks for slack space to be calculated by hand2 while the FAQ says Effective Capacity builds that overhead in18, so our recommendation is to size in the vSAN sizer, noting whether the result is raw or effective capacity so the allowance is not counted twice. The pages do not say whether a Supervisor can be enabled once a cluster is stretched, hence the confirmation in the checklist. Whether the cluster model’s “shared” VM and VCF management networks mean one stretched VLAN and subnet is not stated3, so our recommendation is to plan for stretched Layer 2 there.

Sources

Show all 22 sources
  1. Stretching vSAN Clusters in VMware Cloud Foundation
  2. Stretched vSAN Storage Model
  3. Stretched vSphere Cluster Model
  4. vSAN Stretched Cluster Guide
  5. Stretched vSAN Storage Cluster Storage Model
  6. Stretch a vSAN ESA or OSA Cluster Using the SDDC Manager API
  7. What Are vSAN Stretched Clusters
  8. Deploy and Configure vSAN Witness Host
  9. Bill of Materials 9.1.1
  10. vSAN 9.1.1.0100 Release Notes
  11. vSAN Stretched Cluster Design Considerations
  12. Upgrade ESX to 9.1
  13. Physical Data Center Network Design
  14. vSAN Stretched Cluster Bandwidth Sizing
  15. vSAN Stretched Clusters Network Design
  16. NSX Edge Cluster Models for Dual Availability Zones
  17. Dual Availability Zone Based on NSX Edge vSphere HA Recovery Model
  18. vSAN Frequently Asked Questions
  19. Selecting the Best RAID Configuration for a vSAN Storage Cluster
  20. Expand a Stretched Cluster in VMware Cloud Foundation
  21. vSAN 9.1 New Features
  22. Best Practices for Working with vSAN Stretched Clusters