In a vSphere design for VMware Cloud Foundation 9.1.1 with the October 12, 2026, patches, ESX 9.1.1.0100 (build 25782009) and vCenter 9.1.1.0100 (build 25784172)12, some choices are fixed when the servers are ordered: UEFI HTTPS boot for Zero Touch Provisioning3, a TPM 2.0 chip from VMware’s certified list4, a boot device other than the deprecated USB and SD5, dedicated Memory Tiering NVMe that vSAN does not share6, and whether hosts carry DPUs on vSphere Distributed Services Engine, which cannot take live patches7. Changing them later means work on every affected host.
Our recommendation is single-rack clusters unless a rack loss must be survivable, then Layer 2 multi-rack, Live Patch in its default Auto mode, and a DRAM check on the failover reserve with Memory Tiering.
Which failure the cluster has to survive
The cluster model follows from the largest failure to survive: a host, a rack or an availability zone. One domain can combine several of the four models8. A single-rack cluster keeps every host in one rack and one zone, and vSphere HA protects it against host failures only9. Minimums are three hosts with vSAN and two with FC or NFS, four with either storage for a management domain’s first cluster whose management components are deployed highly available, and six for a stretched vSAN cluster, eight for that highly available first cluster9101112.
The two multi-rack models are designed to survive the loss of a rack, provided storage and spare compute are sized for it. Layer 2 stretches each network across the racks as one broadcast domain, a VXLAN/EVPN fabric included, works for the management domain’s primary cluster and can be stretched across availability zones10. Layer 3 gives each rack its own VLAN and subnet, routed between racks, stays in one zone, serves only additional clusters in the management domain, and needs an uplink profile, a host TEP pool and a sub-transport node profile per rack11. Both serve workload domains and recommend vSAN ESA and separate distributed switches for storage, NSX and vMotion, with at least two physical NICs per switch1011.
On vSAN, rack protection comes from fault domains: at least three racks, each rack’s hosts in their own fault domain, configured by hand in vCenter after cluster expansion. Three racks give redundancy but no automatic rebuild of vSAN components, and the model recommends starting with four vSAN nodes. Fault domains rule out vSAN ESA auto policy management, which must be deactivated, with a default storage policy created by hand where needed. They also rule out reserved capacity, so slack space is calculated by hand. In a Layer 3 cluster, each rack’s vSAN network gateway is that rack’s vSphere HA isolation address and must be highly available and answer ICMP13.
A stretched cluster survives the loss of an availability zone and spans at most two, each zone a single-rack or Layer 2 multi-rack cluster, with the vSAN witness in a third, independent fault domain. vSAN stretched clusters need at least 10 Gbps and under 5 ms of round-trip latency between zones. VM and VCF management networks are shared across zones, ESX management, vMotion, vSAN and host TEP networks are per zone, and a workload domain cluster can be stretched only once the management domain is12. See the vSAN stretched cluster article.
Where a rack loss must be survivable, our recommendation is Layer 2 for its wider management domain and stretch support1011, with one more rack than the storage policy needs, plus rebuild capacity, where objects must be re-protected after a rack loss. Layer 3 suits a fabric already routed per rack, but it adds per-rack NSX objects and narrows the VPC choice: among the connectivity models offering VPCs, Broadcom’s comparison marks only Distributed VXLAN as supporting it, and that model needs an EVPN-VXLAN fabric14.
The host specification
The ESX model asks for hardware on the compatibility list at the latest supported BIOS and firmware, homogeneous hosts, and physical NICs of one speed, vendor and model per cluster, with 25GbE recommended. vSAN ESA hosts need at least 128 GB of RAM. CPU is sized from physical cores, without crediting multi-threading. Management domain vCPU-to-pCPU over-commitment should stay at or below 2:1, with higher ratios supported only under close watch of CPU ready time, while workload domain ratios are set case by case15.
The boot device should be 128 GB or larger, formally recommended for the default management cluster15. Besides USB and SD boot devices, VCF 9.1 deprecates hosts without a persistent OSDATA device and system storage under 32 GB, with removal planned for the next major release5.
For attestation in vSphere 9.1, the TPM must be enabled in UEFI, with Secure Boot on and the TPM set to SHA-256 with the TIS/FIFO interface rather than CRB4. The expiry of Microsoft’s 2011 Secure Boot certificates generally does not affect host Secure Boot on ESX 9.1, also signed with the 2023 certificates, but its effects on Windows and Linux guests are more complex (KB 423893)5. vCenter and ESX 9.1.1 automate the Platform Key update for affected VMs, with VMware Tools and Windows update prerequisites for Windows VMs with a vTPM, and some Windows versions not yet supported16. The ESX model requires each host’s certificate to be regenerated by hand once it has its FQDN, before deployment15.
Bringing hosts into image-managed clusters
The design library requires a vSphere Lifecycle Manager image for every cluster9. Since VCF 9.0 only image-managed clusters are supported, and clusters still on baselines must move to images before ESX is upgraded to 9.117. An image does not force identical hardware, although the ESX model still recommends homogeneous hosts15: a composite image adds alternatives with the same base image and solutions but other vendor, firmware and driver add-ons, matched to hosts by filter rules. For heterogeneous clusters still on baselines, KB 424294 temporarily allows Update Manager so their hosts can reach ESX 9 first17.
Zero Touch Provisioning (ZTP) installs ESX on bare-metal servers from one vCenter-level UEFI HTTPS boot URL, without PXE or TFTP. Each host must trust the vCenter certificate, and network boot uses port 443 as well as 65013. A URL set statically in the firmware needs One Way TLS authentication, and for servers without TLS 1.3 Broadcom suggests another arrangement, such as a TLS 1.2 provisioning server18. DHCP is required if the UEFI cannot take a static IP for boot. The cluster named in the deploy rule determines the host’s ESX image and configuration, and without a complete vSphere Configuration Profile there the host joins with a default configuration19. Deploy rules are Auto Deploy rules, and a cluster can hold several images3. Broadcom calls ZTP the replacement for legacy Auto Deploy, deprecated in VCF 9.020, and VCF does not support stateless hosts21.
A host joining a cluster with Configuration Profiles is remediated automatically only if auto-remediation of newly added hosts is on. It is off by default22 and set per vCenter or cluster19. With it on, Configuration Profiles waits one minute for further hosts, remediates the new host to the cluster configuration and stores differing settings as host overrides, and a host added in maintenance mode returns to it after success22. Our recommendation is to keep auto-remediation off while new deploy rules are proven, then enable it cluster by cluster.
Patching: when hosts still reboot
VCF 9.1 adds live patching for TPM-enabled hosts23, covering VMkernel, user-space daemon and NSX transport node patches while VMs run. Live Patch is on by default in vCenter 9.1, needs an image-managed cluster with DRS at Fully Automated and parallel remediation off, and does not apply when hosts are patched with ESXCLI. Eligible hosts are neither put into maintenance mode nor rebooted, and the remediation precheck reports each host’s live patch impact7. On VCF 9.1.0, loaded emcp, nvidia, nvidia-gpu or scini modules make a host ineligible for VMkernel live patches until they are unloaded (KB 428958). VMs without Fast Suspend and Resume, such as FT, DirectPath I/O and shared-disk cluster VMs, do not block the patch but must be migrated or power-cycled to take hardware changes. In the default Auto mode, eligible hosts are live-patched first and the rest then get maintenance mode or a reboot, while Enforce stops the cluster remediation if even one host needs either7. The mode is set per vCenter and can be overridden per cluster719.
ESX 9.1.0.0100 (build 25433460), a June 2026 security patch, was live-patchable24. ESX 9.1.1.0 (build 25714478) of September 2026 is not: every host reboots, with its VMs migrated or shut down25. ESX 9.1.1.0100, the October 12, 2026, security patch, is live-patchable again, with no host reboot and no VM migration1. Major upgrades never use Live Patch, and for 9.0 to 9.1 the procedure says to select Auto or clear Enable Live Patch17.
Patches and hosts that do not qualify still mean reboots, so the capacity to evacuate a host stays in the design, and a release like ESX 9.1.1.0 stops remediation in any cluster set to Enforce. Our recommendation is Auto as the standing mode, with Enforce only for a release marked live-patchable once the precheck shows every host eligible.
Keeping vCenter available and current
Every workload domain has a dedicated vCenter with its own Single Sign-On domain8. Shared SSO domains are not supported, so each vCenter has its own administrator credentials and password rotation, and every workload domain vCenter runs on the VM management network in the management domain26. Instances upgraded from earlier versions may still share SSO domains8, so our recommendation is to check before adding a domain.
vSphere HA protects vCenter, with restart priority high. vCenter HA, with recovery taking up to 15 minutes, and vSphere FT, which caps the appliance at medium, are not supported. Rack or site protection comes from the management cluster itself: multi-rack, vSAN stretched, or third-party synchronous replication such as a metro cluster26. With the embedded identity broker, maintenance on the management domain vCenter also interrupts authentication to VCF components27.
In 9.1, VMCA-managed certificates renew themselves: the vCenter TLS certificate 5 days before expiry and ESX certificates 30 days before. Certificates from an external authority are not renewed. One API call, deployment/size with the PATCH method, plus a reboot resizes vCenter compute and disk, upward only1928. The resize should follow a backup and is not supported while vCenter runs on snapshots29. Our recommendation is to monitor the vCenter renewal, which leaves five days to fix a failure, and to size vCenter from the start with the workload domain sizing article.
Failover capacity and VM placement
vSphere HA protects every cluster, and the single-rack and multi-rack models recommend admission control for one host failure with percentage-based failover capacity, VM Monitoring, and DRS fully automated at the default medium threshold9. A one-host reserve cannot restart a whole rack’s VMs, so where that is required, our recommendation is spare capacity per rack. Stretched clusters raise admission control to half the hosts, add hosts to the default management cluster in pairs, one per zone, and hold VMs in their zone with a host group, a VM group and a should-run VM-Host rule per zone, groups and rules made by hand12. On the management cluster, the Stretch Cluster workflow pins only the management VMs that exist when it runs to the primary zone, so DRS can place management VMs deployed or scaled out later in either zone (KB 453860).
EVC is recommended for management domain clusters whose hosts share a CPU vendor, at the highest baseline the oldest CPU supports, and on the default management cluster it can be enabled only at bring-up, through the API and a JSON specification9. For workload domain clusters, our recommendation is to record the EVC decision per cluster.
vCenter 9.1.1 adds VM-to-VM affinity and anti-affinity rules through compute policies, for traditional VMs and VM Service VMs, with required or preferred strictness set in the VM spec file16. The DRS documentation advises against applying DRS rules and compute policies to the same non-VM Service VMs, because conflicting constraints can produce unexpected placement30.
In 9.1 enabling Memory Tiering no longer needs a host reboot20, though the host still goes into maintenance mode31, and a second NVMe device can mirror the tier20. The vSphere guidance asks for NVMe at least as large as DRAM at the default 1:1 ratio, hosts whose active memory stays within 50% of DRAM, no memory overcommit, and no NVMe drive shared with vSAN. vMotion of a tiered VM takes 1.5 to 2 times longer6. From vCenter 9.1.1, DRS and HA support Memory Tiering, and HA admission control tracks DRAM alongside total memory, so failover, Broadcom says, no longer fails silently for lack of DRAM16. Our recommendation is to check the failover reserve against both limits, the surviving hosts’ total tiered memory and their DRAM, because a cluster whose VMs fit in tiered memory can still run short of DRAM once a host is gone.
Checklist and hold criteria
Our recommendation is to have this evidence before the step each item gates, and to hold at three points.
- Cluster model. Owner: virtualization architect. Evidence: per cluster the failure to survive, the model and host count against the minimum, for multi-rack the rack count, fault domain map, slack space calculation and storage policy mechanism, for Layer 3 the VPC connectivity model, and for stretching a workload cluster the stretched management domain.
- Host bill of materials. Owner: infrastructure engineer. Evidence: compatibility list entries and firmware levels, UEFI HTTPS boot and its TLS version, a certified TPM 2.0 set to SHA-256 and TIS/FIFO, a boot device of 128 GB or more, at least 128 GB of RAM on vSAN ESA hosts, tiering NVMe at least as large as DRAM, and the DPU decision.
- Provisioning. Owner: vSphere administrator. Evidence: an image on every cluster, deploy rules exported with their target clusters, a complete Configuration Profile per target cluster, the vCenter certificate on the servers, regenerated host certificates, auto-remediation recorded per cluster, and a test host booted with the expected image and configuration.
- Patching. Owner: vSphere administrator. Evidence: the Live Patch mode per vCenter and cluster, DRS and parallel remediation set as Live Patch requires, a precheck per cluster, hosts with KB 428958 modules or DPUs listed, and capacity to evacuate one host.
- vCenter. Owner: platform operations lead. Evidence: HA restart priority high, one SSO domain per vCenter or brownfield exceptions recorded, a vCenter certificate expiry alert, and before any resize a backup and no snapshots.
- Failover and placement. Owner: virtualization architect. Evidence: exported HA and DRS settings, per-rack spare capacity where needed, stretched groups and rules with the KB 453860 check after each management deployment or scale-out, EVC per cluster, the DRAM calculation for tiered clusters, no non-VM Service VM under both DRS rules and compute policies, and an anti-affinity pair tested through maintenance mode and HA failover.
- Ordering servers. Hold while any cluster model or bill of materials evidence is missing. Stopping point: the approved design with no servers ordered. Retry with the missing cluster model or bill of materials record from the checklist.
- Adding hosts to production clusters. Hold while any provisioning evidence is missing or the test host boots with the wrong image or configuration. Stopping point: new hosts in a test cluster with auto-remediation off. Retry with the missing record (image, Configuration Profile, vCenter certificate on the servers, regenerated host certificates, auto-remediation record) or the corrected deploy rule export and a new test boot.
- Production workloads. Hold while any patching, vCenter or failover and placement evidence is missing or fails. Stopping point: clusters running only management or test VMs. Retry with the missing record (Live Patch mode, DPU and KB 428958 host list, evacuation capacity, HA restart priority, SSO check, backup and no-snapshot condition, KB 453860 check, EVC per cluster, non-VM Service VM check) or a passing rerun of the failed test, plus Broadcom’s confirmation where hard separation is mandatory.
Some points stay open. The vCenter 9.1.1.0 release notes support only preferred compute policy strictness after placement16, the DRS page makes required a hard runtime constraint from 9.1.130, and the Compute Policies page lists enforcement through load balancing, maintenance mode and HA failover32. Our recommendation is to design as if only preferred holds until Broadcom confirms required enforcement for the build, a hold criterion where hard separation is mandatory. The multi-rack vSAN rules carry Layer 3 IDs and name the older auto policy management rather than Auto-RAID, the 9.1 default for new clusters1333, so our recommendation is to apply them to Layer 2 clusters too and record each cluster’s policy mechanism until Broadcom confirms. The design pages size FC and NFS clusters from two hosts, but vSphere HA admission control needs three934, so our recommendation is three hosts wherever it runs.
Sources
Show all 34 sources
- ESX 9.1.1.0100 Release Notes
- VMware vCenter 9.1.1.0100 Release Notes
- What is Zero Touch Provisioning with Auto Deploy
- Securing ESX Hosts with Trusted Platform Module
- Product Support Notes
- Memory Tiering Considerations and Best Practices
- Configuring vSphere Lifecycle Manager for Live Patches
- VCF Domain Models
- Single-Rack vSphere Cluster Model
- Multi-Rack Layer 2 vSphere Cluster Model
- Multi-Rack Layer 3 vSphere Cluster Model
- Stretched vSphere Cluster Model
- Multi-Rack vSAN Storage Model
- Workload Connectivity Models
- ESX Model
- vCenter 9.1.1.0 Release Notes
- Upgrade ESX to 9.1
- Image ESX Hosts by Network with a UEFI HTTPS Boot URL Configured Directly in the UEFI Firmware
- What’s New with vSphere in VMware Cloud Foundation 9.1?
- vSphere
- Preparing ESX Hosts for VCF or vSphere Foundation
- Configure the Global Remediation Settings for Clusters That Have vSphere Configuration Profiles Enabled
- What’s New
- VMware ESX 9.1.0.0100 Release Notes
- ESX 9.1.1.0 Release Notes
- vCenter Model
- Embedded Identity Broker Model
- Vcenter Deployment Size update
- Resizing VMware vCenter in VMware Cloud Foundation 9
- DRS Rules and Compute Policy Interactions in vSphere
- Memory Tiering Configuration
- vSphere Compute Policies
- Auto-RAID in VMware vSAN for VCF 9.1
- vSphere HA Admission Control