In VMware Cloud Foundation 9.1, the vSAN architecture and the cluster type have to be settled before the hardware is ordered, because ESA, OSA and storage clusters each set their own hardware terms. vSAN ESA accepts only NVMe devices in a single tier, while vSAN OSA builds disk groups from a flash cache device and flash or magnetic capacity devices12. A vSAN storage cluster, formerly vSAN Max, serves its datastore to compute clusters that contribute no storage, so capacity and compute grow separately34, and Broadcom’s storage cluster guide rules out converting an HCI cluster into a storage cluster in place5. Moving from OSA to ESA likewise takes a new cluster and a workload migration6. The baseline is VCF 9.1.1 with the October 12, 2026, patches, which bring vSAN and both witness appliances to 9.1.1.01007.
Our recommendation is to start a new VCF 9.1 cluster on new hardware as ESA HCI with at least four hosts. It gets Auto-RAID, compression and the Effective Capacity view by default and spends no devices on cache tiers. OSA stays the right choice where the hardware cannot meet ESA’s terms: non-NVMe or magnetic capacity devices, or nodes below 16 cores and 128 GB. A storage cluster fits when compute has to grow without adding vSAN capacity, or when the compute hosts are not certified vSAN ReadyNodes. Datastore sharing lends spare capacity between HCI clusters with hosts already bought.
ESA or OSA: what the hardware allows
ESA takes its node floor from the smallest ReadyNode profiles, vSAN-HCI-SM and vSAN-SC-SM: 16 cores, 128 GB of memory and drives of at least 1.6 TB, with up to 24 drives per node. Less memory per node lowers the number of vSAN drives the node supports. Above that floor, the ESA design recommends multiple NVMe TLC devices per node, in performance class F or higher with an endurance of at least 3 DWPD. The VCF workflows may block ESA cluster creation unless they detect vSAN-certified drives, and Auto-RAID is enabled when certified components are detected1.
OSA’s constraints sit in the disk group: one flash cache device and at least one capacity device, with at least one disk group per node. Two per node is the recommended layout, which means a second cache device that adds no capacity. A storage I/O controller that runs vSAN disk groups must not serve VMFS or other non-vSAN devices, so non-vSAN disks need a controller of their own. The OSA design gives no core or memory floor and prefers CPUs with a higher base clock, because OSA performance scales with clock speed2. Both architectures rule out NVMe devices behind a Tri-Mode controller, in RAID, HBA, pass-through or JBOD mode, and support NVMe only when connected directly to PCIe (KB 314305). Every new cluster must use vSphere Lifecycle Manager images, and imported OSA clusters on baselines must convert to images before the upgrade to VCF 9.012.
An OSA VM without a storage policy gets the vSAN Default Storage Policy with RAID-1. OSA deduplication and compression are switched on or off per cluster, but VCF does not offer compression-only when it deploys an OSA cluster2. ESA compresses by default, and vSAN 9.1 gives every new ESA cluster an Auto-RAID policy when it detects certified components1. Storage clusters require ESA-compatible hardware3, on ReadyNodes certified specifically for storage clusters5, so a dedicated vSAN storage cluster in VCF 9.1 is always ESA.
HCI, storage cluster or shared datastore
The compute clusters that mount its datastore need vSAN networking but neither certified vSAN ReadyNode hardware nor certified local storage devices4. The storage cluster itself is a dedicated ESA cluster of 4 to 32 hosts, each with at least two storage devices, 16 cores, 128 GB of memory and 20 TB of capacity. Seven is the recommended size, enough for FTT=2 with RAID-6 and for the cluster to regain its level of resilience after a sustained host failure. One storage cluster serves up to ten client clusters, and up to 104 client hosts can mount its datastore3. The limit counts the storage cluster too: 128 hosts in total, so 104 clients assume a 24-host storage cluster. The guide recommends at most 16 hosts for a single-site storage cluster, about the number of 2U servers in one rack, and asks for a TPM in every storage cluster host5.
Each compute cluster needs at least two hosts, commissioned as the vSAN Compute Cluster type. It mounts at most five remote datastores, must keep all objects of a VM on one datastore, must set its vSphere HA response to an all-paths-down event to power off and restart VMs, and needs latency of 5 ms or less to the storage cluster. The compute cluster page also requires the client in the storage cluster’s workload domain, because VCF workflows do not cross-mount it across vCenter instances4. The storage cluster guide aims for 1 ms or less5. VCF 9.1 also supports clusters in other workload domains, under a different vCenter, consuming vSAN storage from this one58.
When HCI clusters only have to consume each other’s spare capacity, datastore sharing does it without a dedicated cluster: an HCI cluster serves its datastore to up to ten client clusters, under the same five-datastore and 5 ms limits8. From 9.1 the architectures can mix: an OSA client can mount an ESA or storage cluster datastore89, and an ESA client an OSA one9.
Host counts, Auto-RAID and Reserved Capacity
Three nodes is the HCI minimum, but a three-node cluster will not rebuild components automatically after a failure. Starting with four allows automatic rebuild and Reserved Capacity, and the ESA design adds that, with auto policy management, a four-node ESA cluster gets a capacity-optimized default policy automatically1. That last point describes 9.0 auto policy management, which gave three-host clusters RAID-1 mirroring (KB 451544). Auto-RAID gives them RAID-5, as its table shows from three hosts10.
Auto-RAID is meant to manage resilience regardless of the size or topology of the cluster1, fault domains included. It uses RAID-5 (2+1) with one failure to tolerate on three to five hosts and RAID-6 (4+2) with two from six hosts, both at a protection overhead of 1.5x10. The sixth host raises the failures tolerated from one to two at no extra overhead, but RAID-6 (4+2) then spans all six hosts and leaves none to rebuild on3. Our recommendation is four or five hosts where RAID-5 is enough, and seven where RAID-6 has to survive a host that stays out for days.
Upgraded clusters keep their existing policies until their objects and datastore default policy move to Auto-RAID or the Apply Auto-RAID to all objects option is enabled1112. Broadcom’s vSAN FAQ says to always use Auto-RAID on 9.1 and prefers moving all objects and the default datastore policy to the vSAN ESA Auto-RAID Policy over Apply Auto-RAID to all objects, a catch-all that overrides self-managed policies and, if turned off, may reconfigure objects back to their old policies13. The Auto-RAID blog advises leaving the option on once enabled, because turning it off also disables the Effective Capacity view11, which requires Auto-RAID12. The Auto-RAID policy cannot be used to create, clone or migrate VMs on clusters or compute-only clients running ESX 9.0 or earlier. To use Auto-RAID with a remote datastore on 9.1 or later, the RAID page says you must enable Assume auto RAID on the remote cluster10, while KB 429473 lets the client keep using the Auto-RAID policy once Apply Auto-RAID to all objects is enabled on the server cluster.
In Reserved Capacity, the Host Rebuild Reserve, which absorbs the sustained failure of one host, shrinks as the node count grows: 25% at four nodes and 8% at twelve, instead of a generic 30%, and the design suggests host counts large enough to bring the percentage down114. Reserved Capacity is not supported on three-node clusters, stretched clusters or clusters with fault domains. On a four-host vSAN storage cluster in 9.0, the reserve combined with Auto-Policy ruled out RAID-5, a limitation Auto-RAID removes in 9.11. With Auto-RAID and the Effective Capacity view, the vSAN FAQ and the storage cluster guide call the Host Rebuild Reserve and Operations Reserve toggles no longer relevant513. The storage cluster design still carries the 9.0 warning3, so our recommendation is to record whether each cluster runs Auto-RAID or Auto-Policy.
Rack failure and stretching
The multi-rack vSAN model protects against losing a whole rack. It is built on vSAN fault domains with either the Layer 2 or the Layer 3 multi-rack cluster model and needs at least three racks, each rack its own fault domain configured by hand in vCenter. In the Layer 3 model, each rack’s vSAN gateway serves as an HA isolation address and must be highly available and answer ICMP requests. Three racks give redundancy without automatic rebuild, so four fault domains is the recommended count. Fault domains do not support ESA auto policy management, which must be deactivated, and Reserved Capacity stays off14. Auto-RAID does support fault domains and counts them in place of hosts: three to five racks get RAID-5 with one failure to tolerate, six or more get RAID-6 with two15.
Stretching across two availability zones changes the host minimums, Auto-RAID layouts, HA reserve, stretch order, witness and networks (see the stretched cluster design). Three stretch blockers follow from choices made here: DPU-backed hosts, hosts on different Layer 3 networks within one zone9, and Global Deduplication. Only the Layer 2 multi-rack model can be stretched, while the Layer 3 model stays in one availability zone14.
The vSAN network
10GbE is the minimum for both architectures, but support for 10GbE on ESA is limited: vSAN-HCI-SM is the only ESA ReadyNode profile supported on it, and all other ESA HCI profiles require 25GbE or more. For vSAN data traffic the design asks for 25GbE or faster, for consistent performance. ESA on 10GbE triggers a vSAN cluster compliance check16.
Two physical NICs per node fit small-scale workloads on the smaller ReadyNode profiles. They keep the host on a single distributed switch, where vSAN shares bandwidth with vMotion and NSX and Network I/O Control divides it under contention. Four NICs fit large-scale, IO-intensive workloads on bigger profiles and give storage traffic its own distributed switch and uplinks, with more switches to manage. The network models give no rule for other combinations. In either model, highly IO-intensive workloads might need 100GbE16.
Each single-rack cluster needs a vSAN VLAN, preferably a dedicated one, though clusters in the same rack may share it, and one IPv4 or IPv6 subnet with a gateway, since VCF 9.1 does not support dual-stack vSAN VMkernel networking. The recommended distributed switch MTU is 9000 with the whole path matching, and all vSAN traffic types must use a consistent MTU between 1500 and 9000. The vSAN port group should use Failover Order teaming, set by hand, with Layer 2 inside a rack and Layer 3 between racks16. On HCI clusters, the vSAN gateway serves as the vSphere HA isolation address, with das.usedefaultisolationaddress set to false1.
A storage cluster adds a client traffic type that keeps replication, resync and rebalance traffic apart from client I/O. It needs an extra VMkernel interface and a separate network pool with its own subnet and VLAN, and the storage cluster design advises using it3. On the vSAN-SC-SM profile, storage traffic between storage cluster hosts uses at least 25GbE, while client traffic can run at 10GbE16.
A fabric that stays at 10GbE limits ESA HCI to vSAN-HCI-SM nodes, so larger nodes on such a network point either to OSA or to 25GbE, and our recommendation is to buy the faster switch ports together with the hosts.
Data services after deployment
Global Deduplication on ESA is enabled as a day-2 operation and is not currently compatible with stretched or two-node clusters1. It works cluster-wide as a post-processing setting and supports data-at-rest encryption17, and a vSAN ESA or storage cluster with it enabled cannot be stretched9. It cannot be disabled, only paused, and pausing leaves deduplicated data as it is18. Our recommendation is to leave it off on any cluster that may be stretched. Data-in-transit encryption can be enabled on day 0 or day 2 and data-at-rest encryption on day 2, with a TPM recommended in each host to hold the keys12. From 9.1, data-in-transit encryption also covers traffic between client clusters and vSAN storage clusters17.
Both architectures include integrated File Services12. The vSAN 9.1.1 release notes add the VCF Native Object Store, S3-compatible object storage built into vSAN, as a tech preview, and validated vSAN topologies for Cloud Native Storage19.
Evidence and hold points
Our recommendation is this evidence per cluster.
- Design record. Owner: virtualization architect. Evidence: per cluster, ESA or OSA, HCI, storage cluster or compute cluster, single-rack, multi-rack or possibly stretched, whether Global Deduplication will be enabled, and the reason for any OSA choice.
- Hosts and devices. Owner: storage architect. Evidence: each host model that contributes vSAN storage listed as a ReadyNode for its architecture or role, ESA nodes at 16 cores, 128 GB and drives of 1.6 TB or more, NVMe devices attached directly to PCIe, a TPM in every vSAN host, and on OSA a storage I/O controller used only for vSAN disk groups.
- Protection. Owner: virtualization architect. Evidence: host or fault domain counts against Figure 2, Auto-RAID or a recorded self-managed policy per cluster, the Auto-RAID transition chosen for upgraded clusters, and whether Reserved Capacity is enabled.
- Storage cluster and clients. Owner: storage architect. Evidence: 4 to 32 storage hosts with 20 TB or more each, client and storage hosts within 128 in total, client clusters of two or more hosts, at most five remote datastores per client, and client latency measured at 5 ms or less, aiming for 1 ms.
- Network. Owner: network engineer. Evidence: link speeds per ReadyNode profile, the two- or four-NIC layout, a vSAN VLAN and single-stack subnet with a gateway, a consistent MTU across the path, Failover Order teaming, and for a storage cluster the client traffic network pool.
- HA isolation. Owner: virtualization administrator. Evidence: the vSAN gateway, or each rack’s gateway in the Layer 3 multi-rack model, answering ICMP as the isolation address,
das.usedefaultisolationaddressset to false on HCI clusters, and the all-paths-down response on client clusters set to power off and restart VMs.
Our recommendation is to hold at three points.
- Purchase order. Hold while the design record, the hosts and devices evidence, or the link speeds, NIC count and switch ports are missing or fail. Stopping point: the quote under revision, nothing ordered. Retry with the corrected quote, its ReadyNode listings, device attachment, TPMs, NIC speeds and count, the switch ports and the updated design record.
- Cluster creation. Hold while the protection evidence apart from upgrade transitions, the storage cluster and clients evidence apart from latency, or the remaining network evidence is missing or fails, or while VCF does not detect certified drives on an ESA host. Stopping point: hosts commissioned, no cluster created. Retry with the drive check passing, Figure 2 counts, the policy and Reserved Capacity state per cluster, 4 to 32 storage hosts of 20 TB or more within the 128-host total, client clusters of two or more hosts with at most five remote datastores, and the VLAN, subnet, MTU, teaming and network pool configured.
- Production data and Global Deduplication. Hold production data while any object or the default policy shows neither Auto-RAID nor the recorded self-managed policy, an upgraded cluster’s Auto-RAID transition is unfinished, client latency measured at mount exceeds 5 ms, or the isolation or all-paths-down settings are missing. Hold Global Deduplication while the design record lists the cluster as possibly stretched. Stopping point: test VMs only, deduplication never enabled. Retry with every object’s policy compliance, the mount latency, exported HA settings, the Effective Capacity view where Auto-RAID runs, and a design record keeping the cluster on one site.
Some points stay open. The design pages still recommend Reserved Capacity while the FAQ and the storage cluster guide set it aside under Auto-RAID1513, so our recommendation is Auto-RAID with Effective Capacity on ESA and Reserved Capacity only on clusters without Auto-RAID where it is supported. The multi-rack model asks for auto policy management to be deactivated and does not mention Auto-RAID14, so our recommendation is to check the default policy after the fault domains are created. The RAID page and KB 429473 name different settings for ESX 9.0 clients, so our recommendation is explicit policies on those clients until they run 9.1 or Broadcom confirms the setting. The compute cluster page and the datastore sharing model differ on clients in other workload domains48, so our recommendation is VCF-provisioned clients in the storage cluster’s workload domain, and Broadcom’s confirmation before relying on a cross-vCenter mount.
Sources
Show all 19 sources
- Single-Rack vSAN ESA Storage Model
- Single-Rack vSAN OSA Storage Model
- Single-Rack vSAN Storage Cluster Storage Model
- Single-Rack vSAN Compute Cluster Storage Model
- Design and Operational Guidance for vSAN Storage Clusters
- Refreshing an Existing vSAN Cluster with New Servers
- vSAN 9.1.1.0100 Release Notes
- Datastore Sharing vSAN Storage Model
- Stretching vSAN Clusters in VMware Cloud Foundation
- Selecting the Best RAID Configuration for a vSAN Storage Cluster
- Auto-RAID in VMware vSAN for VCF 9.1
- Monitor vSAN ESA Effective Capacity
- vSAN Frequently Asked Questions
- Multi-Rack vSAN Storage Model
- vSAN Availability Technologies
- vSAN Host Network Models
- vSAN 9.1 New Features
- Pause Global Deduplication on vSAN ESA Cluster
- vSAN 9.1.1.0 Release Notes