VMware Cloud Foundation 9.1 reached general availability on May 12, 2026, and its first maintenance release, 9.1.1, followed on September 3, 20261. For a team on 9.0 or 5.2, the question is which changes need design or runbook work before the first upgrade window. Most add options. A handful change something that works today: ESX 9.1 ends support for some older guest operating systems, NSX stops creating four ESX user accounts that hardening baselines may list, IPFIX on uplink port groups goes away, VCF Automation renames IP spaces, and a vCenter upgraded in place from 9.0 needs a manual hardware version step. Our recommendation is to clear those first, with the gates at the end of this overview, and to choose the target build with the 9.1.1 overview.
Deployment, fleet and licensing
VCF 9.1 introduces VCF management services, a common runtime and set of components behind the lifecycle and operational capabilities2. A new deployment gets a default set of them from the VCF Installer: VCF services runtime, fleet lifecycle, identity broker, software depot, Salt RaaS, telemetry and the license server3. Fleet lifecycle replaces the standalone VCF Operations Fleet Management Appliance. It takes over that appliance’s inventory when it is deployed, while the appliance’s remaining functions, move into VCF Operations 9.14. Fleet lifecycle then installs, upgrades, patches, backs up and restores the management components4.
Licenses move out of VCF Operations into the license server, which a new VCF Operations 9.1 installation deploys automatically4. An upgraded fleet deploys it with the management services once VCF Operations and SDDC Manager run 9.1, in the first instance only, and not where a license server already exists5. In connected mode, VCF Operations downloads a new license file every 24 hours, so manual license file updates are only needed where that download is turned off. Licenses can also be assigned directly to ESX hosts and vSAN clusters connected to a licensed vCenter. These override licenses need enough free capacity and must be compatible with the vCenter license. During a mixed-version period, license usage counts the cores of ESX 8.x hosts together with those of 9.x hosts4.
The installer’s planning workflow turns the chosen topology and components into CPU, memory, storage, VLAN and FQDN requirements and validates them against the target infrastructure before deployment. LACP on the management domain’s distributed switches, previously an API-only option, is now set in the UI with prechecks that the physical fabric is ready for the link aggregation group3, and VCF Operations offers the same option for workload domains4.
KB 452952 says that in 9.1 HA must not be enabled on a Small deployment of the VCF management services, which is not vSphere HA, by any method, direct API calls and scripts included, because that leaves the system unsupported, broken and unrecoverable. Where a 9.1 design needs HA, the KB plans a scale-up to Medium, and it lifts the limit from 9.1.1.0.
One VCF instance can manage up to 5,000 hosts, twice the 9.0 figure, and SDDC Manager can run up to 256 cluster upgrades in parallel4, which in our reading is a scale figure. The ESX upgrade procedure runs the first ten selected clusters in parallel and any further ones in sequence6, so our recommendation is to size upgrade windows on ten. VCF Operations can also create a workload domain without a vSphere cluster: the workflow deploys a vCenter instance and a new NSX Manager instance, or joins an existing one. Nothing in that domain can be patched or upgraded until a cluster is added, and the same holds for every workload domain that shares its NSX Manager4.
Bringing hosts and existing vSphere in
Zero Touch Provisioning boots ESX images over UEFI and HTTPS onto bare-metal servers, several servers from a single HTTPS URL with a static network configuration, so host builds no longer depend on PXE infrastructure or TFTP. Broadcom calls it the replacement for legacy Auto Deploy, deprecated in 9.07, and it builds on the vSphere Auto Deploy service and its deploy rules8.
For existing environments, convergence and import accept vCenter 8.0 Update 3a or later with NSX Manager 4.2 or later without manual component upgrades. Without NSX, the same vCenter versions qualify only after a manual upgrade of vCenter to 9.1. Import also accepts vCenter instances without Enhanced Linked Mode whose NSX Local Managers belong to an NSX Federation, and dual-stack vCenter environments where the VCF instance itself runs dual-stack3. NSX deployments with Bare Metal Edge nodes can be imported as well9. Exact builds still matter: KB 450972 allows only import, not upgrade or convergence, to 9.1.0 from vSphere 8.0 Update 3j and 3k, released after 9.1.0, and no upgrade from VCF 5.2.4. HCX moves under VCF lifecycle: VCF Operations deploys, manages and upgrades HCX Manager and can onboard instances that were deployed by hand4.
Networking
The new Virtual Network Appliance runs network services for distributed VPCs, including a Layer 4 load balancer. A Distributed Transit Gateway can connect directly to an EVPN-VXLAN fabric with no centralized gateway appliance in the traffic path. The management domain can share its NSX Managers with workload domains9. New deployments can run management and workload domains dual-stack, and an upgraded instance can add dual-stack workload domains once SDDC Manager is configured for dual-stack3, though vSAN VMkernel networking for data traffic stays IPv4 or IPv610. Changes made directly in vCenter to distributed switches and datastores, or in NSX to transport zones, transport node profiles and uplink profiles, no longer affect SDDC Manager3.
IPsec VPN, policy-based or route-based with static routes, now works for VPCs with centralized external connectivity. The Distributed Load Balancer is managed independently of the Distributed Firewall, and NSX IPAM can optionally integrate with Infoblox, so VPC subnets can be created from Infoblox network containers. For tenants, the stateful gateway firewall and the distributed firewall, stateful or stateless, need a vDefend Firewall license9.
Two changes reach existing operations. NSX stops creating the regular ESX users mux_user, da-user, nsx-user and lldpVim-user and uses accounts that are not visible to users instead. Our reading is that host account audits and hardening baselines that list those users need updating. The distributed switch moves its IPFIX export to the ConnTrack-based module, and as a result IPFIX for uplink port groups is no longer supported9. Our recommendation is to move any flow collector fed from uplink port groups to another IPFIX source before the upgrade.
Storage and memory
The vSAN What’s New page makes RAID-6 the ESA default11. The design guide enables Auto-RAID when vSAN certified components are detected10, and Broadcom’s Auto-RAID post adds that new clusters pick RAID-6 with six or more hosts and RAID-5 with three to five, and upgraded clusters keep their policies until moved to Auto-RAID12. Global deduplication arrives as a cluster-wide post-process setting that works with data-at-rest encryption, so encrypted clusters can now deduplicate as well11. It is not compatible with stretched or two-node clusters10 and cannot be disabled, only paused, which leaves deduplicated data as it is13. vSAN stretched storage clusters can provide storage across vCenter boundaries, and one site of a stretched cluster can be put into maintenance mode11.
A vSAN storage cluster can mount both OSA and ESA clusters, and a compute-only cluster can mount OSA clusters and storage clusters at the same time. Traffic between client clusters and vSAN storage clusters can now be encrypted in transit. CNS and CSI scale to 50,000 volumes per vCenter11.
Memory Tiering no longer needs a host reboot to enable, only maintenance mode, and VM types it used to exclude can now power on, though some still do not take part in tiering14. It can also mirror its NVMe device in software RAID 1 so that tiering continues when a device fails7.
Lifecycle with less downtime
ESX Live Patch, which applies security patches and urgent fixes while VMs keep running, now also works on hosts with a TPM, and Broadcom says it covers up to 80 percent of patches2. It is off by default and needs a cluster managed by a single vSphere Lifecycle Manager image, hosts without DPUs, DRS turned on and sequential remediation. VMs that cannot use Fast Suspend and Resume, such as Fault Tolerance, DirectPath I/O and shared-disk cluster VMs, must be migrated or power-cycled (KB 419942). Live Patch does not apply to major upgrades, so ESX 9.0 to 9.1 runs with the Auto option, which puts hosts into maintenance mode and reboots them, or with Live Patch off. The Enforce option, which allows only Live Patch, would block the upgrade6. vCenter quick patches carry security or critical fixes, cannot be used for major upgrades, and apply with zero to five minutes of downtime. The services in the patch payload fall into three groups, with zero, up to three, and three to five minutes of downtime7. For full updates, VCF Operations can schedule an optimized window for vCenter and NSX Manager: the vCenter reduced downtime update (RDU) runs its preparation stage first, without downtime, and the maintenance window then holds the NSX Manager node updates followed by the vCenter switchover4.
NSX Edge clusters are now upgraded at the end, after the management domain components and the ESX clusters, and the step that finalizes the NSX upgrade starts once the Edge clusters are done. A cluster upgrade can be limited to selected hosts, so hosts with errors can be skipped, and standalone hosts and single-host clusters come under lifecycle management. Prechecks run on the components’ own capabilities rather than only on SDDC Manager4. Maintenance mode gains a Non-Disruptive vMotion Evacuation option that moves VMs only where their current compute demand fits8. vMotion concurrency can be tuned beyond the former static limit of eight migrations per cluster7.
Operations, identity and automation
Identity gains generic OIDC providers, custom VCF roles and OAuth 2.0 API tokens, VCF Operations no longer stores break-glass passwords, and log management moves inside VCF Operations4. Two migrations matter for existing environments: the identity broker can move from embedded mode to instance mode, and data from VMware Identity Manager can be migrated to the identity broker by script4.
In VCF Automation, providers can delegate vDefend firewalls and Avi load balancing to organizations, give an organization several external connections, and migrate in place from VMware Cloud Director with the Migration Tool, available through a Broadcom representative15. Broadcom licenses vDefend Firewall and Avi Load Balancer separately from core VCF, so the delegation applies where they are licensed16. IP spaces are renamed external IP blocks, and our reading is that existing runbooks and scripts have to follow the new name.15.
Security and recovery
User-Level Monitor becomes the default virtual machine monitor and runs less hypervisor code in privileged mode in the ESX kernel, which Broadcom says lowers the risk of a guest escape compromising the host. AMD SEV-SNP and Intel TDX confidential VMs reach general availability, and vCenter checks its installed files every four hours with File Integrity Monitoring, on by default7. VCF Operations assesses compliance against the VCF Security Configuration Guide and PCI DSS v4.0.1 and, according to its What’s New page, remediates non-compliant findings4.
Cyber recovery workflows use vSAN snapshots to recover into an isolated on-premises clean room211. vSAN adds the pieces around them: a cyber recovery vSAN storage cluster deployed through vCenter Quickstart and protection groups whose membership follows VM tags. vSAN replication can also protect workloads on any storage, with vSAN ESA as the target11. Broadcom’s VCF 9.1 FAQ of November 8, 2026, leaves cyber recovery workflows with EDR integration, including the Carbon Black entitlement for the clean room, out of the core entitlement, with VMware Live Recovery as the separately licensed product for on-premises cyber recovery. Its standard-entitlement answer lists Security Posture Management, the SecOps dashboard, audit trail visibility and compliance checks on VCF components, without naming remediation16. Native object storage, listed for 9.1 as a tech preview2, was announced for a later vSAN patch17.
Upgrade paths, gates and what leaves support
The release notes require a strict component upgrade sequence for 9.1 and give separate procedures for VCF 5.2.x and for 9.0.x. A vSphere 8 environment with Aria Operations 8 follows its own order of upgrade and deployment steps as a first phase, and Broadcom warns that an incorrect sequence results in errors, among them failed license assignment18.
ESX 9.1 ends support for older guest operating systems, among them RHEL 4.x, Oracle Linux 5.x, CentOS 4.x and 5.x, SUSE Linux Enterprise Server 10 SP4 and Debian 7.x, and deprecates Asianux 4.x7. HCX deprecates its self-managed PhotonOS appliances as of 9.1.0, with removal targeted for VCF 10.0.0, and gives HCX 9.1 an automated workflow to move them to the NSX Edge architecture. New service meshes use the enhanced appliance architecture from 9.1, while existing appliances keep the legacy architecture unless they are moved with the Migrating Network Extensions workflow4. The vCenter appliance VM moves from hardware version vmx-10 to vmx-17 in 9.17. KB 403995 makes the manual update mandatory for every vCenter upgraded in place from 9.0, though not after a reduced downtime update, which builds a new appliance, and the update takes effect only after a guest shutdown and restart of the vCenter VM.
The gates, with owners and evidence:
- Upgrade route, change owner: the documented procedure for the source version, and exact source and target builds checked against KB 450972. Evidence: the procedure named in the change record and target-version prechecks without errors, exported to CSV4.
- Guest operating systems, application owners: every VM on a guest operating system whose support ends in ESX 9.1 upgraded, moved or accepted as unsupported. Evidence: the guest OS inventory with a decision per VM.
- vCenter hardware version, vSphere administrator: the upgrade method, in place or reduced downtime, and for in place from 9.0 the KB 403995 step with a restart slot. Evidence: the method and that runbook step. After the step: hardware version 17 on the vCenter VM.
- Host accounts and flow export, security and network teams: hardening baselines without the four NSX users, and no collector left on uplink port group IPFIX. Evidence: the updated baseline and the collector configuration.
- VCF Automation, automation owner: runbooks and scripts that refer to IP spaces updated for external IP blocks. Evidence: a successful run against a 9.1 lab organization. After the step: the same run in production.
- Licensing, license administrator: the license server in place, a manual update path where the daily download is off, and override licenses with free capacity that match their vCenter license. Evidence: the license plan per host and vSAN cluster. After the step: license usage in VCF Operations with all of them licensed.
- HCX, migration owner: every PhotonOS appliance listed with a date for its move to the NSX Edge architecture. Evidence: the service mesh inventory with each appliance’s architecture.
- Live Patch, vSphere administrator: clusters meant to use it meet KB 419942, with every host supporting Live Patch, and the 9.0 to 9.1 window plans for host reboots with Enforce not selected. Evidence: each cluster’s image and remediation settings, and the window plan.
- New 9.1.0.x deployment, architect: HA never forced onto a Small management services deployment (KB 452952). Evidence: the size recorded with the design.
Our recommendation is to hold the window while any gate lacks its evidence, a precheck shows an error, or a VM, baseline, collector or script affected by a removal or rename has no decision, and to stop the next step when an after-step check fails. A hold ends only with the gate’s evidence in hand and a fresh precheck run without errors. A failed step follows its component’s documented retry or recovery procedure, from a backup taken before the change, and is retried only once that procedure is complete, the prechecks are clean and the component’s version and health are verified. Our recommendation is to stop only between completed steps of the documented sequence. A failure inside a domain’s NSX Manager and vCenter window is, in our recommendation, finished within that window through the retry or a Broadcom Support case before any other step starts. The lifecycle guide details the stopping points.
Two points stay open. The What’s New page has VCF Operations remediate compliance findings4, the FAQ says Security Posture Management “will cover” VCF components with remediation, and its standard-entitlement answer lists compliance checks without remediation16, so our recommendation is to confirm with Broadcom what the core entitlement covers before building on remediation. No source says whether the IP space rename reaches API names, hence the test run in the VCF Automation gate.
Our recommendation is to start with the gates other teams own, guest operating systems, baselines and collectors, because they set the date, and to take the upgrade order and its preconditions from the convergence and lifecycle guides.
Sources
Show all 18 sources
- VMware Cloud Foundation 9.1 Release Notes
- What’s New in VMware Cloud Foundation 9.1
- What’s New in VCF 9.1: VCF Installer
- What’s New in VCF 9.1: VCF Operations
- Deploy VCF Management Services and License Server for the VCF Upgrade
- Upgrade ESX to 9.1
- What’s New in VCF 9.1: vSphere
- What’s New with vSphere in VMware Cloud Foundation 9.1?
- What’s New in VCF 9.1: NSX
- Single-Rack vSAN ESA Storage Model
- What’s New in VCF 9.1: vSAN
- Auto-RAID in VMware vSAN for VCF 9.1
- Pause Global Deduplication on vSAN ESA Cluster
- Advanced Memory Tiering Enhancements in VMware Cloud Foundation 9.1
- What’s New in VCF 9.1: VCF Automation
- VMware Cloud Foundation 9.1 Frequently Asked Questions
- Native S3 Compatible Object Storage in VMware vSAN for VCF 9.1
- Upgrade Sequence to 9.1