Deploying VCF Operations for networks starts from one button on the Network Inventory page of VCF Operations, which until then shows only inventory, alerts and NSX health1. The baseline is VCF 9.1.1 with the October 12, 2026, patches: VCF Operations for networks 9.1.1.0100 (build 25774578), a security patch2, on top of 9.1.1.0 (build 25682214) in the Bill of Materials3. Broadcom asks for each vCenter to be added before its NSX Manager4, and the design puts at least one collector in every VCF Instance5. Our recommendation is Extra Large or larger platform nodes whenever Network Map and Intents or flow-based application discovery is in scope.
How it plugs into VCF Operations
There is one instance per fleet, deployed one to one with VCF Operations and managed by its lifecycle6. VCF Operations shows its alerts with a vrni- prefix and launches into its entity dashboards from VMs, hosts and NSX if the VCF Operations user has at least the Member role in VCF Operations for networks7. vCenter and NSX data sources can also be added from Administration, Integrations in VCF Operations, with the Network and Flow option and a collector48. Migrating, editing, activating and deactivating such data sources is restricted, and after an upgrade to VCF 9 their sync into VCF Operations has to be run by hand before the Network Inventory dashboard shows correct data8.
Platform, collectors and where they run
The platform processes and presents the data that collectors pull from data sources such as vCenter and NSX Manager6. The first deployment is one platform node and one collector node, each with a static IP address, IPv4 or dual-stack. VCF Operations names the VMs after their IP addresses and manages them, so they must not be renamed9.
The Simple model places a single platform node and a collector in the default management cluster5, and every node gets a 100 percent CPU and RAM reservation10. The high availability model is a three-node platform of Large or Extra Large nodes, again with a collector in the default management cluster11. Despite the name, the cluster adds performance and scale, not availability, and Medium nodes cannot be clustered until they are scaled up6. In both models vSphere HA restarts the nodes after a host failure, so the management cluster needs failover capacity511, and the product guide recommends HA with Host Isolation and Guest not heartbeating set to Deactivated10.
With several VCF Instances, the design recommends a collector in the default management cluster of each, deployed through VCF Operations fleet management and registered with the platform, as the VCF Operations design article shows5. The Add collector node action asks for the VCF Instance and deploys the node on its management domain vCenter12. Latency should stay within 3 ms between platform nodes and 150 ms from platform to collector, with 120 Mbps between them recommended for the largest sizes. Disks should answer within 5 ms and deliver 7,500 IOPS, platform clocks may drift at most 30 seconds apart, and NTP must be available whenever a node is rebooted10. Our recommendation is to keep all platform nodes in one site and give each remote instance its own collector, since only the platform-to-collector limit allows for wide-area latency.
Sizing from the documented tables
With cores counted at 2.1 GHz, Medium has 10 cores, 32 GB RAM and 1 TB of disk, Large 15 cores, 48 GB and 1 TB, Extra Large 20 cores, 64 GB and 2 TB, and 2 Extra Large 30 cores, 128 GB and 3 TB. Small is for evaluation only. Past 95 percent disk use on any platform node, the UI becomes inaccessible10.
Features come first: Network Map and Intents and flow-based application discovery run only on Extra Large and 2 Extra Large nodes. As a single node, Medium handles 4,000 VMs and 1 million flows a day, Large 6,000 and 2 million, Extra Large 10,000 and 2 million, and 2 Extra Large 15,000 and 3 million. VM counts include vCenter templates, and VM and edge limits count together, so a setup with SD-WAN edges may take fewer VMs10. The design guide puts the clustering point at 10,000 VMs and 4 million active flows6.
Cluster capacity is listed for 3, 5, 7, 10 and 15 nodes in two scenarios. Scenario 1 favors VMs and flows, with application discovery and assurance at limited capacity: three Extra Large nodes take 18,000 VMs and 6 million flows a day, fifteen 2 Extra Large nodes 225,000 VMs and 30 million. Scenario 2 runs those features at full capacity with fewer VMs, for example 12,000 on three Extra Large nodes. Three shapes are deprecated: three Large nodes should move to three Extra Large, seven Extra Large nodes are supported in neither scenario, and fifteen Extra Large should move to fifteen 2 Extra Large. IPv6 flow processing can cut platform and collector capacity by up to 20 percent10.
A Medium collector (5 cores, 12 GB) handles 4,000 VMs and 2.5 million flows a day, Large (10 cores, 16 GB) 10,000 and 5 million, Extra Large (10 cores, 24 GB) 35,000 and 10 million, and 2X Large (20 cores, 48 GB, 350 GB disk) 45,000 and 17 million. However many collectors there are, the platform’s capacity caps their total flows10. Adding a vCenter data source fails validation if its VMs exceed the platform or collector capacity8.
In VCF Operations, Scale Up resizes chosen platform or collector nodes and restarts them, so the service is down meanwhile. Rolling back to a backup taken before a scale-up returns the old size and permanently deletes data from any node added during it, so Broadcom asks for a new backup afterward13. A platform or collector node can be added only after the VCF Operations certificate includes its IP address, or the lifecycle task fails12. The design also recommends a CA-signed certificate listing the FQDN of every node, replaced each time a node is added5, and KB 424807 makes the FQDN and IP address of every platform and collector node mandatory in the SAN for VCF 9.1. Starting at Medium saves 10 cores and 32 GB per node, but moving to Extra Large later is a scale-up with downtime.
Data sources and the accounts they need
For vCenter, the account’s role needs Global.Settings at the root, propagated to children. IPFIX adds Modify, Port configuration operation and IPFIX operation on distributed switches, and Modify, Policy operation and IPFIX operation on distributed port groups. One collector takes up to 10 vCenter instances, and VM-to-VM paths need VMware Tools in the VMs8.
NSX is supported only where vCenter manages the ESX hosts. Add the NSX Manager cluster by its VIP, keep every manager node reachable from the collector, and add all of its vCenter instances first, because adding NSX before them leaves the system about four hours to stabilize. VMs on logical switches in the distributed firewall exclusion list report no flows. A local user with audit-level permissions is enough without IPFIX. DFW IPFIX needs the Enterprise Admin, Network Engineer or Security Engineer role, and latency metrics need Enterprise Admin. In NSX Federation, add only local users, and NSX management addresses must be IPv44.
Other data sources include firewalls, routers, switches, load balancers and containers14, with models and OS versions on the supported products page. Minor releases of a listed major release are supported, newer major releases are not, and only part of the list supports Network Map and Intents. Configuration is read over SSH15. A Cisco Nexus switch, for example, needs a read-only user with the Network Operator role, read-only SNMP for richer data, and configuration polling between 10 minutes and 7 days16. Assurance, and physical routers in path views, need LLDP, and CDP where supported, on the network devices1017.
In 9.1.1, AWS and Azure cannot be added as data sources, and an upgrade disables existing ones, keeping their earlier data viewable until removal. VCF Operations now manages password policy for VCF Operations for networks and certificates for its collector node18. The root password still changes by hand through the OS, as credential management lists, and certificates follow certificate management.
Flow collection
For vCenter, the data source option Enable NetFlow (IPFIX) turns on VDS IPFIX, and for VCF domains VCF Operations for networks updates the NetFlow settings on each cluster’s distributed switch itself58. Flow monitoring has to be active on all port groups of the switch, and from VCF 9.1 uplink port groups can no longer be selected19. Port groups managed by NSX and those with NSX Edges attached are excluded from vCenter IPFIX8.
For NSX, the Enable IPFIX option on the data source brings in distributed firewall flows, which requires the distributed firewall service on the workload domain’s NSX Local Manager45. If the DFW license is missing or the DFW is deactivated, NSX sends switch IPFIX flows instead4. Latency metrics between VTEPs and vNICs come from the ESX hosts, so firewalls between the hosts and the collector must allow TCP 199145.
Kubernetes flows from VKS clusters arrive through Antrea IPFIX, which requires a 9.1 or later vCenter data source, VKS 3.5.1 or later with the Antrea IPFIX property set in each cluster, and the vCenter and NSX data sources on the same collector. Collection stops if the NSX data source is missing, and the Supervisor VDS networking stack, IPv6 flows and external-to-pod flows are not supported20.
Physical flows need a physical flow collector, which serves no other data source. It is added under Accounts and Data Sources, its VM imported into vCenter from an OVA. sFlow goes to port 6343 and is sampled, so flow metrics are incomplete21. NetFlow v5, v7 and v9 are accepted22. Each device needs a flow record matching the 5-tuple and input interface, an exporter to the collector on port 2055, and a flow cache of 30 seconds active and 60 seconds inactive timeout23.
Only TCP and UDP flows are processed, and the flows recorded per client are capped at 1,000 allowed TCP and 500 allowed UDP outbound flows, 50 denied each, with the excess dropped to protect the flow limit from scanners. Virtual flows sent to a dedicated physical collector are dropped. New data sources show flows after three or four hours, and flow collection changes take up to 10 minutes to apply. Past the flow limits, the oldest flows are overwritten or flows are dropped at the collector24.
What the flows are used for
Application discovery groups VMs into applications and tiers from names, tags (NSX tags included), security groups, ServiceNow, a CSV file such as a CMDB export, or flows. Flow-based discovery needs at least 10 VMs, 100 VM-to-VM flows and an Extra Large platform, and improves when load balancers are added as data sources25.
Security Planning analyzes the flows of a chosen scope and period26. Selecting a segment shows recommended firewall rules, exported as XML or CSV, and as YAML for Kubernetes objects27. The feature comparison requires a separate vDefend add-on for firewall segmentation planning and operations, and a separate Avi add-on for the Avi Load Balancer integration28. vDefend also makes License Hub mandatory, one per fleet, as vDefend design in VCF 9.1 sets out.
The layer 2 and layer 3 path topology between two VMs shows load balancers, routing, NAT and the underlay to the top-of-rack ports, but not every physical switch on a layer 2 path, and with NSX 4.x and later no VM-to-VM path in Federation deployments17. Guided Network Troubleshooting keeps up to 5,000 incidents per tenant and covers the last 30 days29.
Access, licensing and recovery
Admin has full access, Member can run analysis, applications and discovery but cannot manage data sources or most settings, and Auditor has read-only access30. VCF SSO is configured by hand in VCF Operations for networks with the identity broker’s issuer address, client ID and secret, and regenerated if the IP address changes31. It needs an enterprise environment and an instance broker, as the identity article notes.
There is no separate license: from version 9 the component is licensed once its connected vCenter is. A vCenter left in evaluation mode after an upgrade to vSphere 9 makes the deployment unsupported and pauses data collection, which must be turned back on by hand after licensing32. The feature comparison places the capabilities in the VCF and VCF Edge columns28. Under the license terms it may manage only cores licensed for VCF or VCF Edge, which matters where VCF and vSphere Foundation share one environment.
The built-in backup keeps configuration only: settings, data sources except physical flow collectors, and alerts. It keeps no flows or applications, stores up to five backups locally and can upload them to SSH or FTP servers33. Fleet backups protect it only as images, through vSphere Storage APIs – Data Protection, as management backup and restore explains. Broadcom’s disaster recovery page assumes VMware Live Recovery, the earlier product now integrated into VCF as Protection and Recovery, paired across both sites, vSphere Replication on every node, a separate protection group with the platform nodes first, and the primary platform node in a higher priority group. IPv4 customization in the recovery plan is not supported, so recover onto an identical network or re-address the nodes afterward with the documented CLI sequence34. The multi-site design recovers the component with VCF Operations through Protection and Recovery, against a 4-hour RTO target.
Some points stay open. The design guide asks for an Extra Large single node yet offers Medium and Large in its Simple model, lacks 2 Extra Large, and still allows 15 Extra Large nodes, which the product guide deprecates, so the figures above follow the product guide561011. The Add vCenter page gives Medium 3,000 VMs with flows enabled against 4,000 on the requirements page810. One page ties NetFlow DNS and subnet enrichment to an unmapped Enterprise license, and the feature comparison names NetFlow v7 and v9 where the product guide says v5, v7 and v92228. The VDS and NSX IPFIX ports are left to Broadcom’s ports and protocols listing15. The NSX IPFIX page says VDS flow records lose their TCP flags, and are dropped, when vCenter is an NSX compute manager35, yet the design recommends NetFlow on every distributed switch in VCF workload domains5. Nor is it settled whether such recovery plans run under the VCF entitlement or need a protection and recovery subscription. As in the protection and recovery design, our recommendation is written confirmation from Broadcom before a design leaves that subscription out.
Before the Install button
Our recommendation is to hold each stage until its items show their evidence.
Before install:
- Architect: VMs and templates per VCF Instance, daily flows, edges, IPv6 and the features in scope. Evidence: a sizing record against the product guide tables10.
- vSphere administrator: capacity for full reservations plus HA failover, the documented HA settings, and storage under 5 ms with 7,500 IOPS. Evidence: reservations against free capacity, the HA configuration and a storage test510.
- Network administrator: a static IP per node, 3 ms and 150 ms latency, 120 Mbps to the platform, and NTP. Evidence: IP reservations, measurements and NTP status910.
- PKI owner: a CA-signed certificate with every node’s FQDN and IP address. Evidence: its SAN list5.
- License owner: vCenter out of evaluation mode, and vDefend or Avi add-ons if their features are wanted. Evidence: the license state and entitlement record2832.
Before the stopping point (platform, collector and vCenter data sources running):
- vSphere administrator: the vCenter role with its IPFIX privileges. Evidence: a passing Validate on each vCenter data source8.
- Backup owner: configuration backups to an SSH or FTP target, and image backups of every node. Evidence: the first completed backup of each kind33.
Before NSX or physical sources, where in scope:
- NSX administrator: a user with the role IPFIX and latency metrics need, the distributed firewall running, no monitored segment in its exclusion list, and TCP 1991 open from hosts to collectors. Evidence: the role assignment, the exclusion list and the firewall rule45.
- Network team: read-only SSH and SNMP access on supported device versions, LLDP on, and exporters aimed at the physical flow collector. Evidence: device versions against the supported products page, and the exporter configuration15162123.
Before production, a scale-up or a node addition:
- Operations owner: each flow source checked three to four hours after it was turned on. Evidence: flows from every source24.
- PKI owner and backup owner: the VCF Operations certificate listing the new node’s IP address, the node certificate with its FQDN and IP address, and a current backup. Evidence: both SAN lists and the backup record12.
Our recommendation is also a new backup after each scale-up or node addition13. KB 430384, where the Add Nodes page sends failed additions, covers VCF Operations nodes only, so a retry for an Operations for networks node needs the corrected SAN lists of KB 424807, a current backup and Broadcom’s remediation in writing.
Sources
Show all 35 sources
- Network Operations
- VCF Operations for Networks 9.1.1.0100 Release Notes
- Bill of Materials 9.1.1
- Add VMware NSX Manager
- Simple VCF Operations for Networks Model
- VCF Operations for Networks Detailed Design
- VCF Operations Integration
- Add VMware vCenter
- Deploy VCF Operations for Networks
- VCF Operations for Networks System Recommendations and Requirements
- High Availability VCF Operations for Networks Model
- Add Nodes in VCF Operations and VCF Operations for networks
- Scaling VCF Management Components
- Adding a Data Source in VCF Operations for networks
- Supported Products and Versions
- Add a Cisco Nexus Switch
- Path Topology
- VCF Operations 9.1.1.0 Release Notes
- IPFIX Configuration on VDS and DVPG
- Using Antrea IPFIX for VKS Flows
- Add a Physical Flow Collector for NetFlow and sFlow
- Flow Support for Physical Servers
- Configure a NetFlow Collector in a Physical Device
- Frequently Asked Questions for IPFIX
- Working with Application Discovery
- Analyze Flow to Perform Security Planning
- Viewing Recommended Firewall Rules
- VMware Cloud Foundation 9.1.1 and VMware vSphere Foundation 9.1.1: Feature Comparison & Upgrade Paths
- Working with Guided Network Troubleshooting
- User Roles
- Configuring VCF SSO for VCF Operations for networks
- VCF Operations for networks License
- About Backing up and Restoring of VCF Operations for Networks Deployment Data
- Planning Disaster Recovery for VCF Operations for networks
- NSX IPFIX Configuration