A Fibre Channel or NFS array can stay. Each cluster in VMware Cloud Foundation 9.1 keeps the principal storage type it was created with, apart from vVols to vSAN, and every host commissioned in VCF is tied to that type. The decision is therefore per cluster and before commissioning: the protocol, and the route into VCF. VMFS on Fibre Channel and NFS v3 can be principal storage for every cluster role in Broadcom’s Storage Models table. iSCSI, NFS 4.1 and NVMe over Fabrics become principal storage only when the cluster enters VCF through convergence or import, and all of these protocols can be added later as supplemental storage1. The baseline is VCF 9.1.1 with the October 12, 2026, patches, which bring VCF Installer and SDDC Manager to 9.1.1.02002. Our recommendation is VMFS on FC or NFS v3 where an array must be principal storage, convergence or import only where the protocol leaves no choice and Broadcom has confirmed the route in writing, and no new vVol clusters.
Principal storage by deployment path
Principal storage is what a cluster is created with, and it can run workloads. Supplemental storage is added later for workloads, templates, backups or ISO images1. The installer documentation says a cluster’s principal storage type cannot be changed, though clusters with other types can join the domain3, as long as all hosts within one cluster use the same type4. A host commissioned for NFS, VMFS on FC or vVols can only join clusters of that type5.
The installer offers vSAN ESA or OSA, VMFS on FC and NFS v3 for the first management cluster3, and the workload domain and add-cluster wizards also offer vVols over FC, NFS or iSCSI46. Convergence makes an existing vCenter the management domain, import makes one a workload domain, and both accept any supported vSphere storage type if one datastore is shared and writable by every host78.
When a converged or imported cluster has several datastore types, VCF picks the principal one in the order vSAN, NFS v3, VMFS, NFS 4.1, iSCSI and vVols, the last marked as deprecated and not recommended. With several datastores of the highest-priority type, the first one in the cluster becomes principal storage78. For convergence, a JSON specification can override the order by naming a datastore with existingDatastoreName7. On additional management clusters, iSCSI and NVMe stay supplemental even on those routes1. Figure 1 combines these pages.
KB 416270 spells out that route for iSCSI, NFS 4.1, FCoE and NVMe over Fabrics: ESX 9 on the hosts, the datastore on one of them, vCenter 9 on that datastore and a cluster of all the hosts, which the VCF Installer converges into the management domain or VCF Operations imports as a workload domain. VCF Operations manages their lifecycle, but commissioning and adding or removing hosts and clusters start in vCenter. Before 9.1 the KB required an inventory sync after those changes, without which lifecycle management was blocked. From 9.1 it is no longer needed. For the appliances it deploys, convergence needs at least three hosts with vSAN or two with external storage in a simple deployment, four for high availability, and 20% free capacity, below which the installer only warns7.
Broadcom’s 9.1.1 feature comparison of November 16, 2026, lists FC and NFS v3 as principal and supplemental storage for VCF and every other array protocol as supplemental only, without the convergence route9. Our recommendation is to get Broadcom’s written confirmation before an iSCSI, NFS 4.1, FCoE or NVMe cluster is converged or imported as principal storage. Convergence version floors and blockers are in the convergence article.
A management domain on the array
For VMFS on Fibre Channel, the installer expects the datastore to exist and be mounted on all hosts before it starts3. Broadcom’s FC model sets a minimum of two hosts, enough only for a simple management domain installation, and recommends four for a high availability installation. It requires at least one HBA per host, every HBA on the compatibility list with the same make, model, firmware and driver, and recommends two or more HBAs, Round Robin with the array vendor’s IOPS limit, VMFS 6, a registered VASA provider, VAAI, and vCenter alarms on datastore capacity. For zoning and LUN masking it refers to the storage vendor’s best practices10.
For NFS v3, the NFS server must already exist and meet the vSphere NFS guidelines, and the installer can reuse the ESX management network’s gateway, VLAN and MTU for the NFS network and bind the datastore to its VMkernel adapter3. An installer appliance on a future management host sits on a local disk and moves to the management storage by Storage vMotion once that exists11. That host also needs the NFS datastore mounted by hand first. The procedure has three variants, by where the host reaches the NFS server, and with a dedicated NFS VMkernel the port group name must match the specification, SDDC-DPortGroup-NFS by default12. The installer validates that datastore, and its name, server and path have to match the specification (KB 420949). NFS on hosts with a single physical NIC is not supported per the 9.1.0 installer release notes13.
The NFS model requires at least two hosts and identical NICs on the compatibility list, and recommends four hosts. It recommends two or more NICs faster than 10 GbE, VMkernel binding, jumbo frames, VAAI and nConnect for more connections per datastore, which means mounting the datastore with esxcli14. Figure 2 sums up the first cluster’s choice, and the vSAN branch is in the vSAN design article.
Workload domains and added clusters
Hosts for an FC workload domain need supported HBAs with their drivers, and the VMFS datastore mounted on every host before they are commissioned. For vVols, every host must reach the array over FC, reach the NFS server from the NFS network in its pool, or run the iSCSI software initiator with, in the page’s words, the VASA provider URL as the dynamic target5, and the VASA provider is registered under the Storage Settings tab first15. The network pool must match the storage. An NFS pool holds vMotion and NFS networks, a VMFS on FC pool vMotion alone or with NFS, and a vVols on iSCSI pool vMotion and iSCSI. External NFS or VMFS on FC storage needs a new pool, not the management domain’s default pool16. NFS and FC host minimums and failover reserve are in the workload domain sizing article.
In vSphere 9.1, NFS v3 and 4.1 datastores can be shared by up to 256 hosts, and NFS 4.1 supports space reclamation through VAAI-NAS Unmap17. First Class Disks on an NFS v3 datastore shared by more than 128 hosts are not supported18.
What VCF automates and what stays with the array
Broadcom’s storage model comparison marks a full SDDC solution, storage policy based management, automated deployment and scale, automated lifecycle, patching and upgrades, and compute-only clusters as vSAN only. VMFS and NFS still take custom VM storage policies with tag-based placement and host-based rules, and VMFS policies can also set the volume allocation1920. Stretched clusters are possible on vSAN, Fibre Channel and NFS, the latter two through vSphere Metro Storage Cluster, and every type in the comparison supports remote clusters. For Fibre Channel, NFS, iSCSI and NVMe over Fabrics, VCF’s automated workflows do not provision or configure the storage, and additional management tools are needed1. Figure 3 sets vSAN beside the two array protocols the installer accepts, with the host minimums: three vSAN hosts for a simple management domain or any workload domain cluster and four for a highly available management domain1, against two for FC or NFS1014.
For stretched FC or NFS clusters, KB 417356 says Broadcom does not test vSphere Metro Storage Cluster solutions itself and asks the storage vendor to confirm testing with VCF 9.x before purchase. The first management cluster supports only stretching all Layer 2 networks, an NFS principal datastore needs its Layer 2 network stretched too, and the maximum supported round-trip latency between hosts in a cluster is 10 ms. Synchronous replication between sites takes the storage vendor’s limit, 5 ms at many vendors and 10 ms at some. Host counts double for the second site, six minimum and eight recommended for a highly available first management cluster. Storage I/O Control is not supported on a vMSC datastore, and vSphere HA and DRS settings are configured by hand.
Supplemental datastores and principal changes
Supplemental datastores are added and changed in vCenter, which VCF 9.1 allows, although creating or deleting datastores can cause configuration drift21. For supplemental NFS 4.1, Storage DRS supports initial placement only, and Storage I/O Control works only with NFS 322. For supplemental iSCSI, the vSphere 9.1 pages disagree on port binding. One rules it out when the targets sit in another broadcast domain or subnet23, while the software iSCSI best practices show bound ports reaching a target subnet through a static route24. Our recommendation is to bind only ports in the target subnet.
If the principal datastore is changed, renamed or decommissioned in vCenter, SDDC Manager keeps a stale reference and later operations such as adding hosts or stretching the cluster can fail21. The Update Primary Datastore workflow (SDDC Manager’s term for principal storage) corrects the reference for a datastore of the same type. The target must be a shared datastore already available on the cluster, and VCF moves no workloads, so they are migrated first2125. Changing type is not supported apart from vVols to vSAN: NFS to VMFS, vSAN to NFS, and vVols to NFS or VMFS are all ruled out. These workflows apply only to clusters created in SDDC Manager. The page sends imported or converged clusters to the sync operation in VCF Operations, although it also says the general sync does not handle the primary datastore reference21.
Two KBs disagree with that page. KB 454549 says the workflow is unavailable by design for imported clusters and points to the SDDC Manager inventory API procedure of KB 452458, which changes the primary datastore record of a cluster created in SDDC Manager or imported to a VMFS datastore. KB 452458 names no source datastore type and does not mention vVols. Our recommendation is to use that route only with Broadcom Support’s written approval for the cluster.
NFS workload domains need one more step after an upgrade. Each host gets a static route to the NFS server through the NFS gateway of its network pool, and reachability is checked from the NFS VMkernel with vmkping, before any cluster is added to the domain or any host to its clusters26.
vVols in 9.1
Broadcom’s 9.1 workload domain pages and storage guide say vVols, deprecated since VCF 9.0, will be removed in a future release (a future major release, in the guide). vSphere 8.x, VCF 5.x and other supported versions get critical bug fixes only until their end of support627. KB 401070, which says older supported versions, adds that vVol certifications for 9.0 were discontinued, that the deprecation covers all VASA Provider capabilities used by storage partners, and that vVols support on 9.0 may be considered case by case through Broadcom. Because of the deprecation, Update Primary Datastore can change a vVol principal datastore to any vSAN type, OSA, ESA, remote or storage cluster, once the vSAN datastore is on the cluster and the workloads are on it25. The end of vVol replication is covered in the protection and recovery article.
Our recommendation is to create no new vVol clusters, to get Broadcom’s statement of the support that applies to existing ones on 9.1.1, and to plan each before its next hardware or array refresh. Keeping the array means a new cluster commissioned for VMFS on FC or NFS v3 and a migration of the VMs, since changing a vVol cluster to either type in place is not supported21. Moving to vSAN keeps the cluster, with local vSAN storage or a mounted remote vSAN datastore. For an imported cluster bound for vSAN, no route is documented, so our recommendation is to ask Broadcom Support.
Sign-off and hold criteria
Our recommendation is to close these items first.
- Principal storage and route. Owner: VCF architect. Evidence: per cluster, the protocol, the route and its row in the Storage Models table, plus Broadcom’s written confirmation for iSCSI, NFS 4.1, FCoE or NVMe as principal storage.
- Fibre Channel. Owner: storage team. Evidence: a per-host HBA inventory matching the compatibility list, zoning and LUN masking signed off by the array vendor’s practices, Round Robin with the vendor’s IOPS limit, and the VMFS 6 datastore mounted on every host.
- NFS v3. Owner: storage team with the network team. Evidence: the NFS server checked against the vSphere NFS guidelines, two or more physical NICs per host, an NFS network in the pool, and, where the installer runs on a future host, the datastore mounted there with the specification’s name, server and path.
- Commissioning. Owner: VCF administrator. Evidence: each host on the compatibility guide, its commissioned storage type and network pool matching its target cluster, with a new pool for external NFS or VMFS on FC.
- Convergence or import. Owner: VCF administrator. Evidence: one datastore shared and writable by every host, the datastore VCF will pick under the priority order or named in the convergence specification, the host minimums met and 20% free capacity shown.
- Stretched clusters. Owner: VCF architect with the storage vendor. Evidence: the vendor’s written confirmation of testing with VCF 9.x, the required Layer 2 networks stretched, measured host-to-host latency within 10 ms and replication latency within the vendor’s limit, the doubled host count, Storage I/O Control off on vMSC datastores, and the HA and DRS settings recorded.
- NFS after an upgrade. Owner: VCF administrator. Evidence: the static route listed on every host and a successful
vmkpingfrom each NFS VMkernel adapter. - Primary datastore changes. Owner: VCF administrator. Evidence: the target shared datastore of the same type on the cluster, the workloads already on it, and for imported clusters Broadcom Support’s written approval of the API route.
- vVols. Owner: platform owner. Evidence: no new vVol clusters, and per existing one the chosen exit and Broadcom’s statement of the support that applies.
Our recommendation is to hold the installer run, a convergence or import, and commissioning while any item lacks its evidence. The safe stopping point is before all three: hosts installed and datastores mounted, with nothing in the VCF inventory. An iSCSI, NFS 4.1, FCoE or NVMe principal route waits for Broadcom’s written confirmation, and any other route for its Storage Models row. A failed FC check is retried once every host lists the datastore and the HBA inventory matches the compatibility list. A failed NFS validation is retried once the installer host shows the datastore with the specification’s name, server and path, and a single-NIC host waits for a second NIC. A host missing from the compatibility guide, or with the wrong storage type or network pool, stays out of the cluster until the guide entry, type and pool match. A convergence or import waits until the host minimums and one shared, writable datastore are shown and the layout, or the convergence specification, selects the right datastore. Capacity below 20% waits for the free space, although the installer only warns. A stretched cluster waits for the vendor’s confirmation, measured latencies within both limits, the doubled host count and Storage I/O Control off. After an NFS upgrade, the stopping point is the upgraded domain without new clusters or hosts until vmkping succeeds from every host. For a primary datastore change, it is the cluster on its current record: Update Primary Datastore runs only once the workloads are on the target, a failed validation is retried with the target shown as shared on the cluster, and an imported cluster’s API change waits for Support’s written approval. For vVols, it is the cluster on its vVol datastore, which stays until no workload remains on it and Broadcom’s support statement is on file.
Some points stay open. The NFS model page also lists NFS 4.1 as supplemental only14. The Storage Models table and the feature comparison have no vVols row, while the workload domain wizard offers vVols169. KB 407058 says vVols are removed in VCF 9.1, which the 9.1 storage guide contradicts27. No page explains why the table allows NFS 4.1 as principal storage on additional management clusters. The FC model recommends a VASA provider10, which KB 401070‘s deprecation of VASA Provider capabilities leaves unexplained for VMFS. KB 416270 drops the inventory sync in 9.1 for clusters built its way, while the out-of-band storage page still sends imported and converged clusters to it21. Our recommendation is to run the sync after vCenter-side changes and to handle the primary datastore reference separately.
Sources
Show all 27 sources
- Storage Models
- VCF Installer / SDDC Manager 9.1.1.0200 Release Notes
- Start a New VCF Fleet or a New VCF Instance Deployment by Using the VCF Installer Deployment Wizard
- Add an SDDC Cluster to a VCF Domain
- Commission ESX Hosts
- Create a New Workload Domain
- Supported and Not Supported Configurations to Converge to VCF
- Import an Existing vCenter to Create a Workload Domain
- VMware Cloud Foundation 9.1.1 and VMware vSphere Foundation 9.1.1: Feature Comparison & Upgrade Paths
- Fibre Channel Storage Model
- Deploy VCF Installer
- Mount NFS Datastore to an ESX Host
- VCF Installer
- NFS Storage Model
- Add a VASA Provider for vVols Storage in Workload Domains
- Network Pool Management
- vSphere
- Product Support Notes
- About Rules and Rule Sets in vSphere Storage Policies
- Create a VM Storage Policy for VMFS Datastore
- Configuration Drift and Out-of-Band Operations in VMware Cloud Foundation
- NFS Datastore Concepts and Operations in vSphere Environment
- Multiple Network Adapters in iSCSI or iSER Configuration
- Best Practices for Configuring Networking with Software iSCSI
- Select the Primary Datastore of a Cluster in SDDC Manager
- Post Upgrade Steps for NFS-Based VI Workload Domains
- Working with vSphere Virtual Volumes