The VCF Installer builds distributed switches, VMkernel adapters and NSX on a physical network it assumes is ready, moving each host from its standard switch to a distributed switch1, but validates only part of what the network needs, so our recommendation is to hold the wizard until every pre-wizard sign-off item has evidence. Hosts converged or imported with their networking are out of scope. The baseline is VMware Cloud Foundation 9.1.1 with the October 12, 2026, patches, which bring VCF Installer and SDDC Manager to 9.1.1.02002.
What the installer asks the network for
The wizard asks for ESX management, VM management for the appliances, VCF management for VCF Operations, VCF Automation and other management components, vMotion, vSAN or NFS, and an NSX host overlay network, each with a VLAN ID, an MTU and a gateway. VM management can share ESX management, and VCF management can share VM management. The VCF management, vMotion, vSAN and overlay networks take IP inclusion ranges of free addresses, at least one per host, inside the port group’s VLAN, without network or broadcast addresses3. Management components default to ESX management, and a dedicated network is documented for security, compliance or operational separation4.
From 9.1.1 the wizard asks for the VPC network configuration: Full Stack VPC, with TEP-based overlay and Distributed or Centralized Connectivity, or VLAN-Backed VPC, without TEPs or a host overlay network. Distributed Connectivity needs a dedicated external VLAN whose gateway CIDR should match the top-of-rack default gateway. Centralized Connectivity is configured after the workload domain exists3.
In Figure 1, ESX infrastructure traffic reaches all hosts, and VM management, at 1500 bytes or more, the first management cluster and any host running Edge nodes. Host and Edge TEPs go to hosts prepared for overlay and all Edge nodes. Edge uplinks, carrying BGP peering, go to Edge nodes with a Tier-0, and RTEPs only to Edge nodes prepared for Federation, both at 1500 bytes and recommended at 9000. Workload VLANs go where needed, at the MTU required5.
VLANs, gateways and how far they reach
Broadcom advises a separate 802.1Q VLAN per infrastructure traffic type in each cluster. A VLAN carrying management or workload VMs needs one VLAN ID on every host of the cluster, across its racks or zones, so vSphere HA and vMotion can move VMs. VMkernel networks can use a different VLAN per rack where the cluster spans racks5, a layout of the Multi-Rack Layer 3 model, which does not apply to the default management cluster of a VCF Instance6.
Every infrastructure VLAN needs a first-hop gateway at its MTU, recommended as a VRRP or HSRP floating address, and for segments stretched between zones one that survives losing a whole zone. The fabric must route between management VLANs and VMkernel networks, whose addresses must be routable within and between the fleet’s data centers5. Zone and site links belong to the multi-site design.
MTU and latency along each path
Geneve packets between TEPs carry the Don’t Fragment flag, so a smaller MTU drops them. Figure 2 summarizes the MTU and design maximum latency per path: 5 ms within a cluster and 10 ms between hosts running one Edge cluster’s nodes, both at a 1700-byte minimum and 9000 recommended, 150 ms at 1500 bytes to a stretched cluster’s witness, 100 ms between a domain’s clusters at a 1700-byte minimum and between an instance’s workload domains at 1500, both recommended at 9000, and 300 ms between instances of a fleet, at 1500 to 9000 bytes7. KB 412252 calls them a critical design recommendation, not an enforced software limit: VCF 9.x installs above them, but exceeding them can degrade workload performance and VCF stability.
A VLAN segment’s MTU must not exceed the fabric MTU5. Host ports carrying TEP traffic must take the host’s largest traffic MTU, at least 1700, ports on hosts with neither TEPs nor Edge nodes at least 1500, and all host ports are recommended at 9000 or more7. The 1700 floor leaves 100 bytes above Geneve’s 1600 for future header growth, and vMotion and IP storage should run jumbo end to end5. The management VMkernel’s VLAN and gateway are recommended at 1500, because vSAN witness traffic may cross WAN links without jumbo frames5, while its switch port still takes the host’s largest MTU7. The workbook requires jumbo frames for vSAN, vMotion, host overlay, Edge overlay and NFS traffic8. Overlay segment MTU belongs to the NSX design.
Routing for the NSX connectivity model
With Edge nodes, in the centralized and NSX segment models, the Tier-0 can use static routes, with or without BFD, OSPF or eBGP, which VCF’s automated workflow and all topologies fully support. OSPF is not supported with NSX Federation and cannot run beside BGP on one Tier-0, iBGP is not recommended because of its full-mesh peering, and plain static routing gives no ECMP7. The workbook expects BGP adjacency, AS numbers and ECMP between Edge uplinks and top-of-rack switches8. In the host fault tolerant Edge model, uplink VLANs stay rack-local, Edge nodes peer only with their own rack’s switches, and BFD detects failures fast9. Where the fabric aggregates links between switches, its vendor must support Edge BGP peering across them7.
Distributed VLAN needs at least one external VLAN and CIDR on every host in the VPC workloads’ span, on the switch and NICs carrying host TEPs, with its gateway reachable from every host, the administrator’s responsibility. Addresses of physical devices or VMs on that VLAN stay out of the VPC External IP block, and such a device may see asymmetric traffic10. The rack fabric tables give the VLAN a highly available gateway, a 1500-byte minimum and 9000 preferred6.
A VLAN-backed VPC runs under a Distributed Transit Gateway with all traffic on physical VLANs, no overlay and no private subnets, and is the default model when existing infrastructure is imported11. East-west traffic crosses the fabric’s VLANs, and the external VLAN and CIDR span the clusters on the distributed switch prepared for NSX, gateway reachable from every host. A public subnet created in vCenter needs an external connection with a gateway IP, an L2-only subnet one without, and vSphere Supervisor or VCF Automation All Apps Orgs still need a Virtual Network Appliance cluster inside the external VLAN span12.
Distributed VXLAN needs an EVPN gateway on the spines or some leaf switches, which peers with the EVPN Route Controller over multiprotocol BGP-EVPN and must advertise it a default route. Each Distributed Transit Gateway maps to one fabric VRF by a Layer 3 VNI, with route targets matching the EVPN gateways. In 9.1.1 the Route Controllers can run Active/Active, two to eight nodes, each peering with every EVPN gateway, so the fabric needs a peer per node. Only Active/Active allows a Layer 3 boundary between the nodes’ BGP-EVPN interfaces, and Active/Standby needs Layer 2 adjacency for its floating peering address. The peering VLAN must reach the EVPN gateway loopbacks in the fabric’s global routing table, and the ESX TEP interfaces sit in that table or reach it through VRF leaking13.
Names, addresses and time
Each component needs a unique FQDN with A and PTR records, resolving to a static, unassigned address outside the services runtime and VCF Automation ranges. The top-level label takes ASCII letters only, the VCF management services’ FQDNs take no capital letters, and containerized services such as the VCF management services, VCF Automation and the identity broker reject .local. With dual-stack networking, FQDNs of capable components must resolve to IPv4 and IPv63. The services runtime needs at least 12 addresses, 30 recommended for growth, and VCF Automation five. If the network already uses the runtime’s internal block, 198.18.0.0/15, it must move to 240.0.0.0/15 or 250.0.0.0/15, which the 9.1.1 installer UI allows. Host TEPs need one address per active distributed switch uplink on each host, except with a TEP-less VLAN-backed VPC14.
Before deployment, each host’s vmk0 must sit on one management NIC on a standard switch, with a static address, DNS servers, the host’s FQDN and no custom DNS suffixes1. Later hosts need A and PTR records and a host name matching the FQDN15. The installer appliance needs a resolvable static address reaching the hosts and VM management, and at most two DNS servers16. At least one DNS and one NTP address in the deployment must match the appliance’s own8. Link-local DNS and NTP addresses need installer 9.1.1.0200 or later2.
Management components sync to an internal NTP source that starts automatically17. The workbook asks for two time sources per instance outside the SDDC, as two A records behind one CNAME, a single FQDN it calls important for cross-instance components8. The fabric design lists VCF Operations, the depot, the license server and SDDC Manager as reaching Broadcom directly, by proxy, or offline for dark sites5. Behind a TLS-intercepting proxy, depot validation needs SDDC Manager 9.1.1.0200 or later2.
Host ports and uplinks
Host ports are recommended as 802.1Q trunks with PortFast and LLDP or CDP, if security policy allows a discovery protocol. Each host should connect to two or more top-of-rack switches, so switch failure or maintenance cannot isolate it. All NICs of one distributed switch must reach the same fabric, VLANs and gateways, and isolated fabrics are not supported for infrastructure traffic. Broadcom recommends independent uplinks, and LACP to the host is supported if the first NIC’s port passes traffic before LACP PDUs arrive, the fabric vendor supports Edge BGP peering across the aggregated paths, and hosts use one VMkernel per traffic type, with Edge nodes on a single uplink design. Static link aggregation and EtherChannel are not supported7.
The installer offers Default Configuration, one switch for all traffic, Storage or NSX Traffic Separation, each adding a second switch on separate NICs, and a custom configuration that maps each uplink to a NIC3. Commissioning tests vMotion with several VMkernel adapters, which MAC address filtering in the fabric can fail15. The 9.1.0 installer release notes list NFS for the management domain on single-NIC hosts as unsupported18.
Tests before, during and after the wizard
With only vmk0 on one NIC before deployment, early tests cover it, the appliance and the switches, and a switch failure test waits for redundant uplinks. The appliance procedure pings each host and resolves every host and NTP server both ways16. The installer validates input: errors must be fixed, warnings can be acknowledged3, and failures are logged in /var/log/vmware/vcf/domainmanager/domainmanager.log on the appliance19. When its vMotion connectivity pre-check fails, KB 453284 points to uplink port MTU, VLAN tagging and a preconfigured profile’s NIC mapping, and gives the path test vmkping -I vmkX -s 8972 -d, a don’t-fragment ping for a 9000-byte path. The NFS procedure uses the same flags20. KB 344313, written for vSphere 7 and 8, sizes the payload as the MTU less 28 bytes of IPv4 and ICMP headers and adds -S vmotion for an adapter on the vMotion TCP/IP stack. KB 453284 also has a setting that disables the check, for an installer bug ignoring standby uplinks while the standard switch still uses the active NIC. Our recommendation is to use it only for that bug, after a manual path test passes.
After deployment, SoS on SDDC Manager runs --connectivity-health (pings hosts, vCenter, NSX Manager and SDDC Manager), --ntp-health (also host clocks within five minutes) and --dns-health (lookups both ways), the last on SDDC Manager only19. Figure 3 orders the tests.
Sign-off and hold points
Our recommendation is to record each item against its workbook value.
- VLANs and gateways. Owner: network engineer. Evidence: a VLAN table matching the wizard and Figure 1, each host port’s trunk, one ID per VM-carrying VLAN across racks, and a VRRP or HSRP gateway at the VLAN’s MTU.
- MTU per path. Owner: network engineer. Evidence: port, VLAN and gateway MTU against Figure 2, at least 1700 wherever TEPs run.
- Routing. Owner: network and NSX engineers. Evidence: rack uplink VLANs and the routing method for Edge nodes, with AS numbers, ECMP and BFD where BGP is used, the external VLAN on every host port in the span with its gateway and excluded addresses, or for Distributed VXLAN the default route, route targets and a peer per Route Controller.
- Firewall rules. Owner: security engineer. Evidence: allow rules in physical firewalls between management components, including the VCF Automation ports in KB 458322 (443, 6443, 9100, 2381, 10257 and 10259).
- Names and addresses. Owner: DNS and IPAM owner. Evidence: lookups both ways for every FQDN from the appliance, reservations for runtime, VCF Automation, TEP and inclusion ranges, and
198.18.0.0/15shown unused or replaced. - Time, Internet and licensing. Owner: infrastructure services. Evidence: two NTP sources behind one CNAME, a DNS and an NTP address shared with the appliance, the proxy or offline method for depot and licensing, and the license server exempt from the proxy.
- Host ports. Owner: network and virtualization engineers. Evidence: a cabling sheet per host matching the profile’s NIC mapping, PortFast, independent uplinks or LACP that passes traffic before PDUs, and no MAC filtering in the vMotion path.
- Installer validation. Owner: virtualization engineer. Evidence: a run with no errors and a reason for each acknowledged warning.
- Paths after deployment. Owner: virtualization engineer. Evidence:
vmkpingat the configured MTU from every vMotion and storage VMkernel, round-trip times within Figure 2 and within 1 ms in a single-site vSAN cluster, SoS output, and BGP and BFD up with the local switches where used. - Switch failure. Owner: network engineer. Evidence: before production, in an agreed window with console access, one top-of-rack switch out of service while management, vMotion and storage paths keep answering.
Our recommendation is to hold at each point below until it has evidence.
- Fabric (VLANs, MTU, host ports, physical firewalls). Hold while an item lacks evidence. Stopping point: hosts with vmk0 only and the wizard not started. Retry with the switch and firewall configuration exported and checked against the workbook, including the KB 458322 ports.
- Routing. Hold while the fabric side is incomplete. Stopping point: for Edge nodes, the management domain without an Edge cluster, otherwise the wizard not started. Retry with the fabric configuration in place, and after Edge deployment BGP and BFD up, where used.
- Names, addresses, time and licensing. Hold while a lookup fails, a range is short, the runtime block overlaps, an NTP source or the CNAME is missing, no DNS and NTP address matches the appliance, or no depot and licensing method is chosen. Stopping point: the wizard not started. Retry with a clean lookup log from the appliance, IPAM showing the runtime block free or replaced, both NTP sources answering through the CNAME, and the method recorded.
- Installer validation. Hold while an error remains or an acknowledged warning has no written reason. Stopping point: the validation page, where you can go back, or edit and re-upload the JSON specification, and re-run3. Retry with a run that shows no errors and a reason for each warning.
- Production. Hold workloads while a path test, SoS check or switch test fails, a round-trip time exceeds Figure 2, or NSX Distributed Firewall rules block micro-segmented management traffic (KB 458322). Stopping point: the management domain with no production workloads and no workload domain commissioned. Retry with repeated
vmkpingand SoS output and a repeated switch test.
A workload domain on another Layer 2 network needs its own network pool21 and the same items before commissioning.
Broadcom’s pages differ: 1500 or 9000 for management VM segments in the fabric design5, a 1500 minimum for vMotion and IP storage against the workbook’s jumbo frames58, 1500 or 1700 for Edge uplinks56, and the design’s witness and cluster latencies7 against the vSAN pages’ 200 ms to the witness, 5 ms between stretched sites and 1 ms within a single-site cluster22. The vSAN bandwidth sizing guide gives no witness figure above 15 hosts per site: 500 ms at one host per site, 200 ms up to 10 and 100 ms at 11 to 1523. Our recommendation is to build to 9000 bytes and 1 ms within a single-site vSAN cluster. For a witness it is 150 ms, 100 ms from 11 hosts per site and Broadcom’s written figure above 15. NSX Federation allows 150 ms from the Global Manager to a location with stretched networks and 500 ms without24, but the design’s 300 ms between instances partly rests on Federation to managed NSX Managers7. Our recommendation is to plan for 300 ms where Federation is the reason, 150 ms where it stretches networks. Between instances, at least 1700 bytes is preferred for workload VMs at 150025. The fabric design’s Internet list includes the license server, but KB 441747 says it needs only internal TCP 443 to vCenter and VCF Operations, without a proxy. Our recommendation is to exempt that traffic from the proxy and choose the licensing method before the wizard. The pages checked give no full installer checklist and no pre-deployment VMkernel path test.
Sources
Show all 25 sources
- Configure the Network on the ESX Hosts
- VCF Installer / SDDC Manager 9.1.1.0200 Release Notes
- Start a New VCF Fleet or a New VCF Instance Deployment by Using the VCF Installer Deployment Wizard
- Network Deployment Options for VCF Components
- Network Fabric Detailed Design
- Multi-Rack Network Fabric Model
- Physical Data Center Network Design
- VMware Cloud Foundation 9.1.1 Planning and Preparation Workbook
- Host Fault Tolerant NSX Edge Cluster Model
- Distributed VLAN Connectivity Model
- NSX 9.1.1.0 Release Notes
- VLAN Backed VPC Connectivity Model
- Distributed VXLAN Connectivity Model for Version 9.1.1
- First VCF Instance FQDNs and IP addresses
- Commission ESX Hosts
- Deploy VCF Installer
- External Services Detailed Design
- VCF Installer
- Troubleshooting VMware Cloud Foundation or vSphere Foundation Deployments
- Post Upgrade Steps for NFS-Based VI Workload Domains
- Network Pool Management
- Networking Requirements for vSAN
- vSAN Stretched Cluster Bandwidth Sizing
- Add a Location
- NSX Segment Connectivity Model