Most of a VCF Automation design in VMware Cloud Foundation 9.1, here 9.1.1 with the October 12, 2026, patches, follows from one tenant decision: All Apps organizations, VM Apps organizations, or both under Mixed Tenancy Mode. The choice determines how tenant workloads are networked and whether a vSphere Supervisor has to be enabled before anyone can deploy1.
Our recommendation for a greenfield platform is All Apps on VPCs, three VCF Automation nodes and a subnet model fixed before installation. For an Aria Automation environment it is All Apps in its own workload domain, or in its own cluster under Mixed Tenancy once Broadcom confirms in writing that its networking advice excludes Mixed Tenancy, VM Apps only for workloads whose networking must not change or whose automation content has no All Apps path yet, and migration milestones for the rest.
KB 408990 sets the sharing rules: several All Apps organizations can share a vCenter and NSX Manager, while an All Apps and a VM Apps organization cannot, and neither can two VM Apps organizations. Mixed Tenancy Mode, new in 9.1 and documented in KB 444058, is the exception for the mixed pair: with the flag on, both types share one vCenter and one NSX instance, and Broadcom presents the shared design mainly as a transition path for Aria Automation customers1.
Choosing the organization type
All Apps carries VM Service, vSphere Kubernetes Service, Data Services Manager and modern applications on Supervisor-enabled infrastructure1. It requires VPCs, and the NSX segment model does not support it2. VM Apps, called a VM Only Org in the network design pages, keeps virtual machines on existing VLAN-backed or NSX segment networking with the routing and firewall model already in place1. VPCs are also recommended for VM Only Orgs, manual deployments and third-party automation2.
The VLAN-backed VPCs of VCF Automation 9.1.1 limit the IP scheme to CIDRs on physical VLANs, with no private networks3. VCF 9.1 can import existing VMs non-disruptively into a vSphere Namespace for VM Service4.
An upgraded Aria Automation environment becomes the first VM Apps organization in the new instance1, and a multi-tenant 8.18 deployment gives one per tenant5. VM Apps workloads can span several VCF fleets or workload domains, a multi-fleet design that does not work with All Apps. For greenfield sites with no Aria Automation dependencies, Broadcom recommends All Apps from the start1.
In 9.1.1, native AWS, Azure and GCP management is deprecated and disabled by default in VM Apps organizations. Once re-enabled in 9.1.1 it does not have to be re-enabled after later upgrades3. For an Aria Automation 8.18.x source the procedure can be applied only after the upgrade, and Broadcom states that the capability will be discontinued in a future release (KB 448993).
The provider gets its own All Apps organization, the Provider Consumption Organization. It can publish blueprints and catalog items to other organizations, but it cannot manage them or use an identity provider other than the provider organization’s6.
Mixed Tenancy, separate clusters or separate domains
Under Mixed Tenancy Mode, the VM Apps organization is created first and fully configured, including its vCenter and NSX Manager cloud accounts, before a VCF Automation region is configured against the same vCenter and NSX Manager1. After an Aria Automation upgrade the VM Apps organizations already exist, so our reading is that their configuration only needs confirming before the All Apps region is added.
With the flag on, both types run in one shared cluster, cheaper at the start but with a high potential for competition between functional groups, or in separate clusters under the shared vCenter, with what Broadcom calls true resource isolation at a higher initial hardware cost1. Without sharing, the design library’s five tenancy models apply: a dedicated workload domain per organization under a shared management domain gives each its own environment, and the range ends at a dedicated fleet with its own VCF Automation per tenant. The library gives no criteria for choosing a model beyond operational flexibility, compliance needs and scalability7.
In Broadcom’s phased model, workloads co-exist in VM Apps while new services are piloted in All Apps and eligible workloads and users move over time. The Supervisor that All Apps needs goes on the existing cluster if it has the capacity, or on a new cluster under the same vCenter1. On a greenfield site, our recommendation is to turn the flag on only if VM Apps is needed, since it fixes the order of configuration, and to meet isolation or compliance requirements with separate workload domains or fleets.
Broadcom places the shared cluster in small or pilot environments with homogeneous workloads and low SLA requirements. Its design table calls separate clusters mandatory for large deployments with diverse, mission-critical workloads and stringent SLAs1. Our recommendation is to reserve the second cluster from the start for a pilot expected to grow.
The centralized connectivity design advises in general against mixing another network consumption vehicle in the same workload domain when VCF Automation is in use8. It does not say whether that covers Mixed Tenancy, which puts VM Apps networking and All Apps VPCs in one workload domain, even on separate clusters.
Regions, quotas and namespaces
A region is one or more Supervisors sharing an NSX Local Manager, which should provide networking to all of them. All clusters and zones of a Supervisor must belong to one vCenter. A region that spans several workload domains needs one NSX Local Manager shared across them, and separate regions serve greater scale or physical separation9. A region can still span vCenter instances10.
Through region quotas one Supervisor can serve several organizations, and for each vSphere Zone a quota sets CPU and memory limits and reservations and the VM and storage classes allowed10. In 9.1 a quota can cover several Supervisors in a region, and a region’s whole capacity can be shared among organizations11. Projects carry users and groups, catalog sharing, and approval and reclamation policies10. The vSphere Namespaces in them each take limits from a namespace class and stay in one region, and every organization starts with editable small, medium and large classes9.
Argo CD as a VCF Service, a 9.1.1 tech preview installed from the Provider Management UI, lets organization administrators deploy instances with VCF Automation sign-in, but all instances in VCF Automation together manage at most 30 vSphere Namespaces. Argo CD support for a new Kubernetes minor version trails VKS by two to four months3.
Tenant networking and vDefend
VPCs cannot be consumed through NSX Global Manager, and cloud users of an All Apps organization should touch the NSX UI or API only to troubleshoot2. VPCs meant for VCF Automation must not be configured outside it12. Each organization gets a dedicated NSX project, with its own transit gateway and IP block allocation, when the provider creates its regional network configuration13.
The NSX Default Project stays with the Supervisor control plane’s system VPCs and is recommended for Supervisor namespace VPCs, unless it is also consumed another way, such as VPCs created in the vCenter UI. With centralized connectivity, All Apps organizations and vSphere Supervisor require an Active/Standby transit gateway, and Large or Extra Large Edge VMs or bare-metal Edges are recommended8.
The distributed VLAN model needs no NSX Edge nodes, supports Auto-SNAT, custom NAT and load balancing through Virtual Network Appliance (VNA) or Avi Load Balancer, requires VNA nodes for stateful services and has no VPN support. The model comparison lists the gateway firewall only under centralized connectivity14. The VLAN-backed VPC model requires a VNA cluster and, per organization, a Distributed VLAN external connection created by hand in VCF Automation15, and it offers no NAT, no VPN, no private VPC subnets and no Multi-Rack Layer 3 support14. From 9.1.1 a distributed VXLAN model also serves All Apps, with VNA nodes, an EVPN Route Controller and an EVPN-VXLAN fabric, again without VPN214. Our reading is that a tenant that needs IPsec VPN is tied to centralized connectivity, whose Tier-0 or Tier-0 VRF connections offer IPsec VPN and the gateway firewall12.
A namespace can have its own VPC or share one, workloads that need segregation belong in different VPCs, and since a VPC spans one region, namespaces in different regions always get different VPCs12. In 9.1 providers can delegate vDefend, so organization administrators run their own transit gateway and distributed firewalls, with out-of-the-box VPC security profiles and role-based labels for dynamic security groups, and create several transit gateways with NAT, IPsec VPN and the vDefend gateway firewall11, perimeter services that come with a centralized connection12.
Identity, organizations and projects
The provider and each organization need an identity provider, or access is limited to the single local admin account created at installation and, in an organization, to its first user, a local Organization Administrator. The provider authenticates through VCF Single Sign-On with the identity broker, LDAP or SAML, and the design requires the same identity provider across all VCF fleet components. Organizations can use OIDC, LDAP or SAML16.
Organizations are isolated at the resource, network and identity layers, and each has its own user directory. Broadcom advises defining organizations by business structure, and where several departments share one directory, a single organization separated by projects may fit better13.
Portal access alone grants no resources. A user also needs a project role, Project Administrator, Project Advanced User, Project User or Project Auditor, and that role applies to every namespace in the project. For service providers, the design recommends distinct administrator roles and multi-factor authentication for all privileged accounts17.
The appliance: model, size and subnet
Broadcom recommends the High Availability model for production1819, a three-node cluster with application-level availability18. The Simple model is one Small node in the default management domain vSphere cluster, restarted by vSphere HA if its host fails20. It has no application-level availability, suits proofs of concept, evaluation, development, test and small non-critical workloads, and resizing it to Medium or Large converts it to High Availability with three nodes automatically18. High Availability nodes, also protected by vSphere HA, can be resized later, though the size still calls for analysis up front21.
In 9.1 the installer’s Small size is the only option for the Simple model, and from 9.1.1 it is the default for both models19. In 9.1, HA must not be enabled on a Small deployment by any method, which leaves the system unsupported and unrecoverable, and Broadcom says to scale up to Medium (KB 452952). For VCF Automation, the fleet sizing page gives one Small node in Simple, one Medium node in High Availability Small, and three Medium or Large nodes in High Availability Medium or Large22. Our reading is that one node in High Availability Small leaves VCF Automation without application-level availability, as in Simple, though from 9.1.1 Broadcom calls the instance-wide small size optimized for production environments that require high availability (KB 452952).
The 9.1.1 Planning and Preparation Workbook also counts one VCF Automation node for High Availability Small but sizes it Small, and gives Small 24 vCPU, 96 GB of memory and 600 GB of disk, Medium the same compute with 900 GB of disk, and Large 32 vCPU, 128 GB and 1,200 GB per node23. A three-node Medium cluster takes 72 vCPU, 288 GB of memory and 2,700 GB of disk from the management domain.
In the shared subnet model, the one VCF Installer uses, VCF Automation takes seven addresses on the default management network: one for its VIP, one for its own VCF services runtime and five for the nodes. The dedicated subnet model mostly serves a DMZ, or separates user-facing from management networks for regulatory or security reasons. VCF Installer cannot deploy it: the subnet must exist first, and installation goes through the VCF Operations fleet management API. Moving VCF Automation off the default management network later may require a redeployment24, so our recommendation is the dedicated model now if either reason may arise.
The installer asks for two FQDNs, one for VCF Automation and one dedicated to its runtime, and five node addresses, contiguous up to 9.1.0.300 and not necessarily so from 9.1.0.400. The runtime’s internal IPv4 network is 198.18.0.0/15, 240.0.0.0/15 or 250.0.0.0/1519. In 9.1 the fleet lifecycle component manages VCF Automation. An upgrade to 9.1.1 fails when the runtime and VCF Automation share one FQDN, and its resolution asks for all FQDNs in lower case (KB 457537). The October 12 patch takes VCF Automation to 9.1.1.0200, build 25801570, applied through VCF Operations25.
The native Kubernetes load balancer, configured at deployment, cannot be removed. An external one comes afterward, forwards to it and needs its own VIP, FQDN and certificate21, with VMware Avi Load Balancer as the load-balancing design’s example26. Its health monitor should probe /health over HTTPS on port 8008, which on new installations from 9.1.0 serves HTTPS only (KB 452419). Moving the VCF Automation VMs out of their resource pool or folder makes later patching, deployment and scale-out fail19. Broadcom puts VCF Automation before the migration service engine: in upgrades to 9.1.1 the reverse order blocked both3, and the 9.1.1.0200 notes, listing that deadlock as resolved, keep the order25. On stretched clusters in 9.1.1, nodes deployed as a Day-N operation are not automatically added to the AZ1 DRS host-affinity rule and have to be moved into it by hand3.
Open points and gates before the first tenant
Open: the bimodal page sets no timeline or criteria for finishing the move to All Apps and does not cover retiring a VM Apps organization or switching Mixed Tenancy Mode off again1, no page cited here describes an imported VM keeping its address on a VLAN-backed VPC, or whether distributed VLAN connections offer the gateway firewall. Sources diverge: KB 408990, barring two VM Apps organizations from one vCenter or NSX Manager, against one per tenant after a multi-tenant upgrade5, release notes allowing mixed-case FQDNs3 against an installer forbidding capital letters19, and KB 452952, which gives no procedure for the VCF Automation node, against the single VCF Automation node in High Availability Small. Our recommendation is the conservative side of each: separate workload domains for the two organization types until Broadcom confirms in writing that the advice excludes Mixed Tenancy, centralized connectivity for any tenant that needs VPN or the gateway firewall, lower-case FQDNs, a Medium or Large profile, and a written Broadcom answer before upgrading 8.18 tenants sharing a vCenter or NSX Manager or before a migration plan relies on VLAN-backed VPC import or on retiring VM Apps.
- Provider architect: organization types, Mixed Tenancy and cluster layout. Evidence: an approved design record naming the VM workloads that stay in VM Apps and why, the flag state, and the clusters for each organization type and the Supervisor113.
- Provider administrator, under Mixed Tenancy: the VM Apps organization configured first. Evidence: its vCenter and NSX Manager cloud accounts validated, with timestamps before the All Apps region on that pair is created1.
- Network owner: a connectivity model per region and tenant. Evidence: Edge or VNA clusters in the region, an Active/Standby transit gateway for centralized connectivity, a Distributed VLAN external connection per organization for VLAN-backed VPCs, and each VPN or gateway firewall need mapped to a centralized connection81415.
- Identity owner: identity providers for the provider and each organization. Evidence: a named, non-local administrator signed in to Provider Management and to each organization portal, and multi-factor authentication on privileged accounts1617.
- Fleet administrator: profile, subnet model and names. Evidence: an installer profile that gives VCF Automation three nodes, or a signed acceptance of a single node, seven free addresses on the chosen subnet, and distinct lower-case FQDNs for VCF Automation and its runtime with forward and reverse DNS records192224.
- Lifecycle administrator: VCF Automation on 9.1.1.0200, the migration service engine patched after it, and a backup, since both models recover by restore. Evidence: both versions in VCF Operations and a successful backup3202125.
- Load balancer owner, for an external load balancer: a monitor on /health over HTTPS, port 8008. Evidence: a healthy pool on that monitor and both portals loading through the VIP (source 21, KB 452419).
Our recommendation is to hold the installer run until the fleet administrator’s evidence exists, to hold regions and organization networking until the provider architect’s and network owner’s items are approved and, on a shared vCenter and NSX pair, the VM Apps cloud accounts validate, and to hold tenant onboarding while any other item lacks its evidence. The safe stopping point is VCF Automation deployed and patched, identity providers configured, and organizations with quotas and regional networking but no tenant users or workloads. A retry needs the corrected profile, addresses and DNS records, the approved design record, cluster layout and connections, timestamped cloud account validation, a named sign-in, the versions and backup, or a healthy pool.
Sources
Show all 26 sources
- Bimodal Consumption Design for VM Apps and All Apps Workloads
- Network Consumption Models
- VCF Automation 9.1.1.0 Release Notes
- VMware vSphere Supervisor Release Notes
- Create a VCF Automation Organization for VM Applications
- Provider Consumption Organization
- Tenancy Deployment Models
- Centralized Connectivity Model
- Understanding Supervisors, Regions, vSphere Zones, vSphere Namespaces, & Classes
- Understanding VCF Automation All Apps Organization Multi Tenancy Model
- VCF Automation
- Understanding Workload Networking within VCF Automation
- Understanding Organizations and Projects
- Workload Connectivity Models
- VLAN Backed VPC Connectivity Model
- VCF Automation Identity and Access Management Design
- VCF Automation Role Base Access Control
- VCF Automation Models
- Start a New VCF Fleet or a New VCF Instance Deployment by Using the VCF Installer Deployment Wizard
- Simple VCF Automation Model
- High Availability VCF Automation Model
- VCF Fleet Sizing Models
- VMware Cloud Foundation 9.1.1 Planning and Preparation Workbook
- Network Design Options for VCF Automation Instance Deployment
- VCF Automation 9.1.1.0200 Release Notes
- VCF Automation Load-Balancing Design