Skip to content

NSX design in VCF 9.1: NSX Manager, transit gateways, VPCs and TEPs

Creating a VMware Cloud Foundation 9.1 workload domain fixes three NSX choices: whether the domain gets its own NSX Manager instance or joins an existing one, how its VPCs reach the physical network, and what the fabric must carry for tunnel endpoints (TEPs). The baseline is VCF 9.1.1 with the October 12, 2026, patches, which for NSX is 9.1.1.0100, build 257629401.

Our recommendation is a dedicated three-node NSX Manager instance for any domain with its own upgrade schedule or failure tolerance, and Distributed VLAN with a host fault tolerant Virtual Network Appliance (VNA) cluster as the default for VPCs. VPN or a gateway firewall in front of VPCs leads to the centralized model, a standards-based EVPN-VXLAN fabric to Distributed VXLAN, and IPv6 workloads or networks extended across NSX instances to NSX segments.

One NSX Manager instance or one per domain

From 9.1 a workload domain can join the management domain’s NSX Manager instance2, which 9.0 did not allow3. Attached domains share the instance’s management and control plane, so a failure there has a larger blast radius. They also share its scale limit, and its upgrades and patches affect all of them. A dedicated instance keeps a domain independent on all three counts, and domains sharing an instance can also share its NSX Edge clusters4. Each dedicated instance adds one or three NSX Manager appliances to the management domain2.

Broadcom’s 9.1.1 Planning and Preparation Workbook lists a Medium NSX Manager for up to 128 hosts and 5 vSphere clusters, and Large for up to 1,024 hosts and 256 clusters5. Every attached domain’s clusters count toward the instance’s limit, and the workload domain sizing article details. From 9.1.1 a domain that joins shares the instance’s full stack VPC with all full stack VPC or NSX TEP-configured domains on it. If the shared instance was deployed in an IPv4-only VCF domain, a dual-stack workload domain that joins it must still use IPv4 between its components2.

Our recommendation is to share an instance only between domains that are upgraded together and can accept a common failure domain, and to make it Large if more than five clusters or 128 hosts may ever attach. A domain that fails any of these tests gets its own instance, including one whose vCenter or hosts may have to stay on an older release.

Dedicated instance
Shared instance
Footprint
Dedicated instance: One or three more NSX Manager appliances in the management domain for each domain
Shared instance: No added appliances, and in 9.1 a domain can join the management domain’s instance
Management and control plane
Dedicated instance: The domain’s own
Shared instance: One for all attached domains, with a larger blast radius
Scale
Dedicated instance: Independent
Shared instance: Constrained, as the clusters of every attached domain count toward the instance limit
Edge clusters
Dedicated instance: Edge clusters only where its connectivity model uses them
Shared instance: Can share the instance’s NSX Edge clusters
VPC network stack
Dedicated instance: The domain’s own transit gateways
Shared instance: Full stack VPC shared from 9.1.1
IP version and network stack
Dedicated instance: The domain’s own choice
Shared instance: IPv4 between components if the instance sits in an IPv4-only domain, and a VLAN-backed domain fails where the default transit gateway already serves full stack VPCs
Upgrades
Dedicated instance: On the domain’s own schedule
Shared instance: Affect every attached domain, and new 9.1 features stay inactive until the hosts of all attached domains are upgraded
Figure 1. A dedicated or a shared NSX Manager instance for a new workload domain in VCF 9.1.

A new instance runs as Simple, a single node that needs fewer resources, or as High Availability, three nodes that the wizard recommends to keep the management and control plane available and minimize upgrade downtime2. Simple recovers more slowly from a node failure, and upgrades affect its management and control plane and may affect deploying, powering on, restarting and migrating VMs6. The three-node model has no control plane impact during upgrades7. Our recommendation is High Availability for any shared instance, since every attached domain inherits those effects.

High Availability places all three nodes in the management domain’s default cluster on the VM management network, on one Layer 2 network for the cluster’s virtual IP. The recommended DRS anti-affinity rule keeps them on separate hosts, and the design requires at least four hosts so that after a host failure the three nodes still run on separate hosts7. The virtual IP does not balance load, so API requests reach one node, and for high API churn Broadcom documents a variant with an external load balancer8.

North-south traffic: Edge clusters or Virtual Network Appliances

A Centralized Transit Gateway runs on an NSX Edge cluster with a Tier-0 gateway9. A Distributed Transit Gateway runs on each ESX host without Edge nodes10. Edge clusters are added after the workload domain exists, while a VNA cluster can be deployed with the domain when vSphere Supervisor needs one, or later2.

The centralized model needs at least two Edge nodes. Broadcom recommends an Active/Active Tier-0 gateway, which scales out to eight Edge nodes, but only an Active/Standby Tier-0 supports stateful services. VCF Automation All Apps Orgs and vSphere Supervisor require an Active/Standby transit gateway, and since the two HA modes are independent, the Tier-0 above it can stay Active/Active. With north-south services enabled, which NAT requires, traffic between VPCs also crosses the Edge nodes. They peer over their own VLANs, one per physical switch, on /28 or larger subnets9. It is the only VPC model listed with VPN or a gateway firewall, and its north-south throughput depends on the number and type of Edge nodes11.

The Distributed VLAN model needs at least one external VLAN across the span of the VPC workloads, on the distributed switch and NICs that carry the host TEPs, with its gateway reachable from every host. VNAs must sit inside that span, and addresses of physical devices or VMs on the VLAN must be excluded from the External IP block. Where the fabric cannot provide such a VLAN, the design page asks for another model, and our recommendation is then the centralized model. NAT, DHCP relay to external servers (from 9.1.1) and the VNA load balancer require a VNA cluster. If Avi Load Balancer is the only stateful service, no VNA cluster is needed, but vSphere Supervisor and All Apps Orgs require one, with north-south services and Default Outbound NAT enabled10. Traffic not redirected to VNAs can approach host NIC line rate, but there is no VPN or Multi-Rack Layer 3 vSphere Cluster Model11.

A VNA is a virtual appliance only, and each stateful service instance runs Active/Standby, never Active/Active12. The host fault tolerant VNA model requires at least two VNA nodes. Without a Best Effort Restart compute policy, a DRS anti-affinity rule keeps them apart, and a host can enter maintenance mode only if the cluster has one host more than VNAs. From 9.1.1 that policy can replace the rule. Each node is then bound to its host and shut down rather than migrated during host upgrades, one host group per host must exist before the Network Connectivity wizard or VNA cluster workflow starts, or be assigned after deployment, and a user-initiated maintenance mode shuts the node down whether or not a healthy peer can take over13. The host fault tolerant Edge model has the same policy and warning14.

The 9.1.1 Distributed VXLAN model connects VPCs to tenant VRFs in the physical fabric15. Broadcom’s comparison requires a standards-based EVPN-VXLAN fabric, and of the VPC models it marks only the Distributed VXLAN models as supporting the Multi-Rack Layer 3 vSphere Cluster Model11.

The model adds an EVPN Route Controller cluster, which must belong to the Distributed Transit Gateway’s NSX instance and cannot be shared across instances15. In the 9.1.1 Active/Active mode, every Route Controller node keeps its own BGP sessions to the EVPN gateways16. Active/Active allows two to eight nodes and Active/Standby exactly two. In both modes Medium is required for production, and the nodes are recommended on two vSphere clusters in separate racks. Route Controllers run on VNA nodes distinct from those for stateful services, so NAT or any other stateful service means two VNA clusters15.

Our recommendation is to start from Distributed VLAN with a host fault tolerant VNA cluster, which needs no Tier-0 and keeps NAT and private subnets. Racks routed at Layer 3 lead to Distributed VXLAN only if the fabric qualifies. A domain that will never need NAT or private subnets can drop the host TEPs with VLAN-backed VPCs. For general-purpose or advanced load balancing Broadcom recommends Avi Load Balancer, and customers already using the built-in NSX load balancer may keep it until May 30, 2027, if they hold the equivalent Avi licenses, one Service Unit per 100 qualifying cores, co-termed with VCF (KB 439411).

Choosing VPC connectivity in VCF 9.1.1Follow questions A through D. A: a need for VPN or a gateway firewall leads to centralized connectivity. Otherwise, B: a standards-based EVPN-VXLAN fabric with tenant VRFs leads to Distributed VXLAN. Otherwise, C: if an external VLAN spans the VPC workloads, continue to D. If not, choose centralized connectivity. D: workloads that will never need NAT or private subnets can use VLAN-backed VPCs without host TEPs. Otherwise choose Distributed VLAN.VCF 9.1.1 connectivityAVPN or gatewayfirewall needed?YesCentralizedNoBStandards-basedEVPN-VXLAN fabricwith tenant VRFs?YesDistributedVXLANNoCExternal VLAN spansthe VPC workloads?NoCentralizedYesDNAT and private subnetsnever needed?YesVLAN-backed VPCpossibleNo host TEPsNoDistributed VLAN Choosing VPC connectivity in VCF 9.1.1Follow questions A through D. A: a need for VPN or a gateway firewall leads to centralized connectivity. Otherwise, B: a standards-based EVPN-VXLAN fabric with tenant VRFs leads to Distributed VXLAN. Otherwise, C: if an external VLAN spans the VPC workloads, continue to D. If not, choose centralized connectivity. D: workloads that will never need NAT or private subnets can use VLAN-backed VPCs without host TEPs. Otherwise choose Distributed VLAN.VCF 9.1.1 connectivityAVPN or gatewayfirewall needed?NoYesCentralizedBStandards-basedEVPN-VXLAN fabricwith tenant VRFs?NoYesDistributedVXLANCExternal VLAN spansthe VPC workloads?YesNoCentralizedDNAT and private subnetsnever needed?NoYesDistributedVLANVLAN-backed VPCpossibleNo host TEPs
Figure 2. Recommended VPC connectivity in VCF 9.1.1, based on VPN and gateway firewall needs, fabric capabilities, external VLAN availability and workload requirements.

Broadcom’s workbook gives NSX Edge nodes and VNAs the same four sizes, each with 200 GB of disk: Small at 2 vCPU and 4 GB of memory, Medium at 4 vCPU and 8 GB, Large at 8 vCPU and 32 GB, and Extra Large at 16 vCPU and 64 GB5. The single-zone Edge and VNA designs recommend Large or Extra Large, with Large the best balance for most deployments, particularly Edges that only forward north-south traffic and VNAs running NAT1314. For vSphere Supervisor and All Apps Orgs the centralized model gives the same advice, with bare-metal Edge nodes as the alternative9.

In the host fault tolerant models, both appliance types are recommended at a 100% memory reservation, and where workloads in the same cluster also reserve memory, the design warns that VMs may fail to power on or restart under vSphere HA1314. Moving from Medium to Large raises that reservation from 8 GB to 32 GB per node.

VPCs and how VCF Automation consumes them

The VPC consumption model is required for VCF Automation All Apps Orgs and recommended for manually deployed workloads, VM Only Orgs and third-party automation. In an All Apps Org, cloud users create VPCs in VCF Automation and should use the NSX UI or API only to troubleshoot. VPCs cannot be consumed through NSX Global Manager, so networks extended across NSX instances with NSX Federation still need the NSX Segment Consumption Model17. VPCs do not support IPv6 yet2, while the NSX segment and VLAN models list IPv6 workloads11.

From 9.1.1 the wizard offers Full Stack VPC, the TEP-based overlay with centralized or distributed connectivity, or VLAN-Backed VPC, essential VPC services without TEPs or private CIDRs2, and its east-west traffic between hosts crosses the physical VLANs18. There is no NAT, VPN, private VPC subnet or Multi-Rack Layer 3 vSphere Cluster Model, and each public subnet created in the vCenter or NSX UI needs a new VLAN, though All Apps Orgs can share one external VLAN11. VLAN-backed VPCs are the default when existing infrastructure is imported into VCF16, and VCF Automation 9.1.1 can consume them19. A deployment with vSphere Supervisor or All Apps Orgs still requires a VNA cluster, which also gives Avi Service Engines their DHCP addresses where Avi is deployed18.

Each new VLAN-backed domain gets its own network span, also on a shared instance, and only its first cluster joins it. Later clusters are added by hand to that span or another18. SDDC Manager 9.1.1 creates such a cluster without a span or transit gateway, and associating a span re-prepares the cluster for NSX, with host downtime (KB 454415). Clusters it imports or syncs under one vCenter share one span, with connectivity issues if their VLANs differ or they share no distributed switch. NSX cannot change a transit gateway’s network stack from full stack VPC to VLAN-backed VPC while VPCs are attached20. A VLAN-backed domain on a shared instance whose default transit gateway already serves full stack VPCs therefore fails to deploy, and KB 452453‘s recovery edits the failed workflow to add a transit gateway for its span. Our recommendation is to add each later cluster to its span before workloads land on it, and to give a VLAN-backed domain a dedicated instance unless that separate transit gateway is planned.

The design guides recommend the Default Project for Supervisor namespace VPCs and an NSX project per All Apps Org, and advise against mixing another consumption method, such as VPCs created in the vCenter UI, into a domain that VCF Automation uses. In the centralized and Distributed VLAN models, every NAT address, public subnet and load balancer VIP comes from the external IP block, which holds at most five CIDRs, with /24 or larger preferred910.

TEPs, MTU and the distributed switch

Geneve packets carry the Don’t Fragment flag, so an undersized MTU drops them. The design requires at least 1700 on the VLANs and first-hop gateways for host and Edge TEPs, since Geneve needs 1600 and the rest is headroom for future header growth. It recommends 9000 with jumbo frames end to end, and overlay segments must use an MTU 200 bytes below the host TEP MTU21. The Edge TEP MTU must match the distributed switch MTU and is set by hand in NSX Global Fabric Settings14. With Edge nodes, the recommended global gateway MTU is the Tier-0 external interface MTU minus 200, such as 88009.

Host TEPs need a static IP pool or DHCP on the host overlay VLAN, except in 9.1.1 VLAN-backed VPC domains, and the overlay stays IPv4 even in a dual-stack workload domain2. The host fault tolerant Edge model recommends a separate TEP VLAN for Edge nodes, routed to the host TEP VLAN14.

The wizard’s recommended Default profile puts all traffic on one distributed switch. Other profiles move storage traffic, NSX traffic or both onto their own switches and NICs2, which takes more switch ports and at least six NICs with redundancy when storage and virtual networking traffic are both separated22. From 9.1.1 the clusters of a domain can share one distributed switch in greenfield deployments, and later clusters can share the first cluster’s switch21622.

Upgrades on a shared instance

A domain whose vCenter is still on 9.0.x or 8.0.x runs on a 9.1 NSX instance in a pinned state, limited to the features of that vCenter release, and new NSX 9.1 features stay inactive until the ESX hosts in all attached workload domains are upgraded2. Patches reach every attached domain too4. The order of component upgrades is in the lifecycle article.

Checklist and hold criteria

Before the workload domain wizard:

  • Network architect: the instance for the domain. Evidence: its upgrade group, accepted failure domain and expected hosts and clusters against the Medium and Large limits45.
  • VI administrator: management domain capacity. Evidence: room in the default cluster for one or three NSX Manager nodes, and four hosts there for High Availability67.
  • Network architect: the connectivity model. Evidence: no IPv6 or cross-instance networks planned in VPC domains, and the answers to Figure 221117.
  • Network engineer: DNS and TEP addressing. Evidence: NSX Manager FQDNs resolvable in DNS, VNA FQDNs and addresses for Full Stack VPC, and a static pool or DHCP scope on the host overlay VLAN unless the domain is VLAN-backed2.
  • Network engineer: TEP path MTU. Evidence: at least 1700 on every TEP VLAN, first-hop gateway and routed hop between TEPs, 9000 where jumbo frames run end to end21.
  • Network engineer: the external VLAN for Distributed VLAN or VLAN-backed VPCs. Evidence: the VLAN and CIDR on every host in the span, its gateway reachable from each, VNAs placed inside the span, and device addresses excluded from the External IP block10.
  • Network architect: a VLAN-backed domain on a shared instance. Evidence: a default transit gateway without full stack VPCs, or a separate one planned (KB 452453).
  • Security administrator: distributed firewall licensing. Evidence: a vDefend license applied through License Hub (KB 446503).
  • VI administrator: versions on a shared instance. Evidence: vCenter and host versions of every attached domain against the pinned states, and NSX at build 2576294012.

Before Edge or VNA clusters are deployed (before the workload domain wizard when a Supervisor VNA cluster comes with the domain), and when clusters are added:

  • VI administrator: placement. Evidence: one host group per host beforehand if Best Effort Restart is used, otherwise the anti-affinity rule and one host more than nodes1314.
  • VI administrator: memory. Evidence: capacity for a 100% reservation per node beside the workloads’ own reservations51314.
  • Network engineer: centralized peering. Evidence: one peering VLAN per BGP-capable switch, on /28 or larger subnets9.
  • Network engineer: Distributed VXLAN. Evidence: EVPN gateways ready to peer with every Route Controller node, Medium nodes and two racks1516.
  • VI administrator: each later cluster of a VLAN-backed domain. Evidence: the span name in the cluster’s network configuration (KB 454415).

Our recommendation is to hold the wizard while any item in the first list lacks its evidence. The safe stopping point is the unsubmitted wizard, and a retry needs that evidence shown. A VLAN-backed domain that fails to deploy on a shared instance stops at the failed task, and a retry needs the workflow edited per KB 452453 to a new transit gateway for the span, default one off, or Broadcom support’s written confirmation. Edge and VNA deployment waits for the second list, stopping at the domain without them or VPCs until the evidence is shown. A later VLAN-backed cluster stops before it receives workloads and resumes once its span name shows.

Open points: no cited page describes moving a domain between instances, KB 439411 does not say whether the VNA load balancer counts as the NSX load balancer, the comparison lists no gateway firewall for the VNA models, and it leaves the centralized model unmarked for Multi-Rack Layer 3 clusters. Until Broadcom answers, our recommendation is to treat the instance as permanent, use the VNA and Edge load balancers only for the Supervisor and VPC services and Avi for anything else, rely on the distributed firewall in the VNA models, which needs a vDefend license applied through License Hub (KB 446503), and choose Distributed VXLAN for racks routed at Layer 3.

Sources

Show all 22 sources
  1. NSX 9.1.1.0100 Release Notes
  2. Create a New Workload Domain
  3. VCF Taxonomy
  4. VCF Domain Models
  5. VMware Cloud Foundation 9.1.1 Planning and Preparation Workbook
  6. Simple NSX Manager Model
  7. High Availability NSX Manager Model
  8. NSX Manager and Control Plane Models
  9. Centralized Connectivity Model
  10. Distributed VLAN Connectivity Model
  11. Workload Connectivity Models
  12. Virtual Network Appliance Cluster Models
  13. Host Fault Tolerant Virtual Network Appliance Cluster Model
  14. Host Fault Tolerant NSX Edge Cluster Model
  15. Distributed VXLAN Connectivity Model for Version 9.1.1 and Later
  16. NSX 9.1.1.0 Release Notes
  17. Network Consumption Models
  18. VLAN Backed VPC Connectivity Model
  19. VCF Automation 9.1.1.0 Release Notes
  20. VCF Installer / SDDC Manager 9.1.1.0 Release Notes
  21. Network Fabric Detailed Design
  22. Distributed Switch Models