Four decisions shape external storage on vSphere Foundation 9.1.1 before production VMs arrive: the first cluster’s principal storage, each array’s path policy, each share’s NFS version, and the failure tests that must pass. The first is made in the VCF Installer, which offers only vSAN, VMFS on Fibre Channel and NFS 3, and a cluster’s principal storage type cannot be changed later1. The baseline is ESX 9.1.1.0100 of October 12, 2026, a live-patchable security release2. ESX is a vSphere Foundation component in the 9.1.1 Bill of Materials3. Storage built from the hosts’ own disks belongs to the vSAN design article.
What vSphere Foundation includes
Broadcom’s 9.1.1 feature comparison of November 16, 2026, marks VMFS over Fibre Channel, iSCSI, FCoE, NVMe/FC, NVMe/TCP and NVMe/RDMA for vSphere Foundation, together with NFS 3 and NFS 4.1, array integration (VAAI) for block and NFS storage, Storage DRS, Storage I/O Control and workload VMDK clustering4. NFS is file access with no direct LUN access, and raw device mappings work on Fibre Channel and iSCSI but not on NFS5, a difference the failover clustering article follows through for shared cluster disks.
A VMFS datastore on Fibre Channel for the first cluster must already exist and be mounted on every host before the wizard runs. An NFS 3 server must meet Broadcom’s NFS guidelines, and if the VCF Installer runs on one of the future hosts, the datastore must be mounted there too. The wizard can bind the NFS datastore to its VMkernel adapter so that NFS traffic cannot flow through another one. A different principal type needs a new cluster1. Other transports are added in vCenter once the cluster exists, as the cluster and host article describes.
NVMe namespaces arrive over Fibre Channel, RDMA (RoCE v2) or TCP and show up as storage devices, like LUNs6. Unlike SCSI LUNs they support no RDMs, core dumps, SCSI-2 reservations or VAAI plug-ins, although clustered VMDKs work on both. One namespace must not be reached over two transport types, a namespace cannot be registered until an active path is discovered, and NVMe over RDMA needs Ethernet switches that support a lossless network7.
How ESX picks a path
Multipathing runs in the Pluggable Storage Architecture (PSA), a VMkernel layer coordinating VMware’s Native Multipathing Plug-in (NMP), the High-Performance Plug-in (HPP) and any third-party multipathing plug-ins (MPPs). A third-party MPP can run alongside the native modules or take over failover and load balancing for the devices it claims, and claim rules decide which module owns each device. NMP serves SCSI devices. Its Storage Array Type Plug-in (SATP) handles array-specific operations, such as activating passive paths on active-passive arrays, and its Path Selection Plug-in (PSP) picks the physical path for each request89.
Three PSPs come with ESX. Most Recently Used (VMW_PSP_MRU), the default for most active-passive arrays, takes the first working path found at boot, moves only when that path fails and, in the generic case, does not move back. Fixed (VMW_PSP_FIXED), the default for most active-active arrays, uses a preferred path and returns to it after a failure. Round Robin (VMW_PSP_RR), the default for many arrays, rotates I/O through the paths, only the active ones on active-passive arrays, and its optional latency mechanism weighs bandwidth and latency per path10. An iSCSI or FC device that no claim rule assigns gets VMW_SATP_DEFAULT_AA with Fixed. Devices claimed by VMW_SATP_ALUA default to Most Recently Used, which takes an active-optimized path, or an active-unoptimized one when none is optimized, and moves to an active-optimized path once one becomes available. Some ALUA arrays need Fixed instead, for which Broadcom refers to its compatibility guide or the array vendor11. An SATP claim rule can carry its own default PSP12, which overrides these defaults.
NMP cannot claim NVMe-oF namespaces, and HPP is their default plug-in7. HPP supports only active/active and implicit ALUA targets and balances with path selection schemes instead of PSPs. LB-RR is the default. LB-IOPS moves after 1,000 I/Os to the path with the fewest outstanding I/Os, LB-BYTES after 10 MB to the path with the fewest outstanding bytes, LB-Latency samples each path’s latency, and FIXED keeps a preferred path13. Uneven controller load on an NVMe datastore is therefore a question for the HPP scheme.
Fixing an overloaded controller
KB 452961 describes the pattern for vSphere 7.x, 8.x and 9.x: an iSCSI array whose first controller runs hot while the second sits almost idle, both healthy. The ALUA plug-in had claimed the LUNs with Most Recently Used, so each host kept its I/O on one working path and left the active paths through the other controller unused. The KB confirms this with esxcli storage nmp device list, which shows each device’s SATP, path policy and working paths, and switches each device to Round Robin in the vSphere Client.
Broadcom’s storage guide is more cautious: the defaults usually need no change14, and the path policy the system sets should not be changed without understanding the implications15. The array vendor’s values break the tie. The compatibility guide lists the SATP and PSP for each array16, and an SATP claim rule added with esxcli storage nmp satp rule add can set a default PSP and PSP options for every device it matches, after which the host must be rebooted12.
Our recommendation is to compare each device with the vendor’s published PSP first and, where the built-in rules do not give it, add a claim rule on every host before the first LUN is presented. A per-device change does nothing for LUNs created later, and a rebuilt host falls back to the ALUA default until someone repeats the edits. A reboot per host is cheap before production and awkward after it.
With Round Robin in place, our recommendation is to check whether its latency mechanism is active before treating an idle path as a fault. Path use then follows the workload, and light load may leave some paths idle, so compare under production load. The mechanism samples 16 I/Os per path and re-evaluates latency every three minutes by default, and setting Misc.EnablePSPLatencyPolicy to 0 turns it off17. If the policy matches the vendor’s and the load is still uneven, the cause lies beyond host path selection, and the array vendor is the next stop.
Fabrics and storage networks
For Fibre Channel, Broadcom’s model typically has two or more HBAs per host, one or more fabric switches and one or more storage processors, so that ESX can fail over between HBAs and, where the array has several, between storage processors. While a path fails over, storage I/O can pause for 30 to 60 seconds, usually longer on active-passive arrays, and Windows guests need a disk timeout of at least 60 seconds18.
With software iSCSI the multipathing plug-ins cannot see physical NICs, so each NIC needs its own VMkernel port bound to the initiator. An independent hardware adapter cannot share multipathing with software or dependent adapters in the same host18. Each VMkernel adapter gets one active uplink and sits in the array ports’ subnet, and port binding is left out when the target ports are in another broadcast domain or subnet19. On a distributed switch that means one port group per NIC20. Bound ports open a session to every target portal, so two ports and two portals give four sessions, and a portal unreachable from any bound port can fail its sessions and slows rescans. Without binding, routing picks one VMkernel port per portal21. LACP does not work with software iSCSI port binding, although iSCSI multipathing over a LAG without binding does22.
For a separate storage fabric, the wizard’s Storage Traffic Separation profile creates a second distributed switch on its own NICs1. Broadcom’s networking best practices connect a switch’s adapters to one physical network and give all its VMkernel adapters the same MTU23, so our recommendation is a separate switch for jumbo-frame storage, as the network design article sets out.
NFS 3 uses one TCP connection and one server address per datastore, so it has no multipathing, and spreading load means more datastores on separate connections. NFS 4.1 multipaths through session trunking, over several server addresses, where the server supports it. Client ID trunking is not supported24. Both versions can open extra connections with nconnect, up to four per datastore by default and eight with the advanced option, with no more than 256 across all mounted NFS datastores. Binding a datastore to a VMkernel adapter stops its traffic from drifting to another adapter when the intended one fails25. Every host that mounts the datastore in a cluster must use the same connection count26.
Choosing the NFS version
Kerberos is available only with NFS 4.1, Storage I/O Control only with NFS 3, and Storage DRS supports NFS 4.1 for initial placement only. Site Recovery Manager cannot use NFS 4.1 datastores for array-based replication, although vSphere Replication works with them. ESX does not convert NFS 3 datastores to NFS 4.1. The routes are a new datastore and Storage vMotion, the storage vendor’s conversion method, or an unmount from every host and a 4.1 mount27.
The two clients lock files differently, so mounting one share as NFS 3 on some hosts and NFS 4.1 on others can corrupt data. ESX does not prevent it, so the NAS server must export each share with one version only2829. With NFS 3 or NFS 4.1 without Kerberos, every host needs root access to the volume, typically through no_root_squash, or no VM can be created on it28. NFS 3 mounts need identical server and folder names on every host, or the hosts see two datastores and vMotion can fail29. VAAI-NAS includes Unmap, which reclaims space for VMs on thin-provisioned NFS 3 and NFS 4.1 datastores30.
Our recommendation is NFS 4.1 where the NAS supports session trunking or Kerberos is required, unless those datastores need Storage DRS load balancing or array-based replication with Site Recovery Manager. The installer offers only NFS 3 for principal storage.
Datastore layout
Broadcom’s SAN guidance puts one VMFS datastore on each LUN15. Fewer, larger LUNs ease creating and resizing VMs, mean fewer datastores to manage and stay further from host and array limits on LUNs and paths. More, smaller LUNs waste less space, allow different RAID levels per application, reduce contention and let the path policy and disk shares be set per LUN, and a Microsoft cluster needs each cluster disk resource on its own LUN31. VMFS6 adds automatic space reclamation and 4Kn devices, a host mounts up to 512 datastores of either version, and VMFS5 cannot be upgraded to VMFS6, only replaced with VMs migrated32.
Datastore clusters cannot mix NFS with VMFS, or replicated with non-replicated datastores, and should not mix datastores with and without hardware acceleration33. Storage I/O Control is listed for vSphere Foundation4, but the vSphere 9.1 resource management guide says its components are deprecated as of VCF 9.034, and KB 385396, written for VCF 9.0, says Storage I/O Control policies keep only limits, not shares or reservations. Our recommendation is not to build on it, and to keep I/O-heavy VMs off LUNs shared with everything else.
External datastores also carry vSphere HA heartbeats, which tell a failed host from a partitioned or isolated one. vCenter picks two heartbeat datastores per host by default, up to five with das.heartbeatdsperhost, preferring different LUNs or NFS servers. A vSAN datastore cannot serve, but storage reached over a path independent of the vSAN network can35. Our recommendation is two small external datastores even for a cluster that keeps its VMs on vSAN.
Our recommendation is also to create shared datastores from vCenter. Before ESX 9.1.1, two administrators in separate Host Client sessions on hosts sharing a LUN could each create a VMFS volume on it, the second overwriting the first36.
Failures to rehearse
All paths down (APD) means no path to the device is available and is treated as temporary. Permanent device loss (PDL) means the device has failed or been removed and is not expected back37. During APD the host keeps retrying. After the default timeout of 140 seconds it stops retrying non-VM commands, VM I/O keeps retrying, and the VMs stay responsive enough to be powered off or migrated38. PDL needs the matching SCSI sense codes, NVMe error codes or iSCSI login rejections on all paths. The host then closes VM I/O, a device that comes back is treated as new with no guarantee of data consistency, and a device that fails without those codes stays in APD39. vSphere HA reacts through VM Component Protection: for PDL it can issue events or power off and restart VMs, for APD it adds conservative and aggressive restart policies, and it cannot restart VMs if host monitoring or VM restart priority is turned off40.
Broadcom’s SAN guidance asks what happens when each link, switch and HBA on the topology map fails15. Figure 3 turns that into tests on the finished cluster, with the array vendor’s procedure for anything touching the array.
Our recommendation is to run the tests on 9.1.1 hosts. ESX 9.1.1 fixes a race in the NFS 4.1 client that could crash several hosts with a purple diagnostic screen when a second APD began during recovery from the first, and an Emulex lpfc driver race that could crash hosts when target node IDs changed during an array upgrade36.
Sign-off before production
Our recommendation is to close these items before the first production VM moves to external storage.
- Path policy. Owner: virtualization engineer. Evidence:
esxcli storage nmp device listfrom every host on ESX 9.1.1 or later, each device’s SATP and policy matching the array vendor’s values, and any claim rules in place before the first LUN. - NVMe-oF. Owner: virtualization engineer. Evidence: the HPP scheme agreed with the array vendor and no namespace reached over two transports.
- iSCSI. Owner: network team. Evidence: one VMkernel port per NIC with one active uplink, and the expected session count on every host.
- NFS exports. Owner: storage team. Evidence: each share exported over TCP in one NFS version, with root access for the hosts, identical NFS 3 server and folder names, and one connection count per cluster.
- Guests and HA. Owner: virtualization architect. Evidence: a Windows disk timeout of 60 seconds or more in the template, two heartbeat datastores per host, host monitoring and VM restart priority on, and the PDL and APD responses recorded.
- Path failover. Owner: virtualization engineer, with the network and storage teams. Evidence: per host, one HBA or storage NIC disconnected, one switch restarted with every host checked, each device losing only the expected paths, and the VM I/O pause measured against 30 to 60 seconds.
- Controller failover. Owner: storage team. Evidence: each controller failed over and back with the vendor’s procedure, then load compared, and if it stays on one controller, the paths the array reports as active-optimized.
- NFS failover. Owner: storage team. Evidence: with NFS 4.1 trunking, one server address removed and the datastore still available. With NFS 3, the NAS vendor’s own failover.
- APD. Owner: virtualization engineer, in a maintenance window. Evidence: every path to a test datastore removed while its LUN stays presented, for example by disconnecting the cables or switch ports of a non-production path set, as Broadcom’s APD causes describe38, the APD events and the test VM’s behavior through the 140-second timeout recorded, and the VM Component Protection response as designed.
- PDL. Owner: storage team with the virtualization engineer. Evidence: a test LUN holding only a disposable VM unpresented at the array, the host showing PDL rather than APD, the VM Component Protection response as designed, and cleanup with Broadcom’s PDL procedure: power off and unregister its VMs, unmount the datastore and rescan every host that had access41.
Some points stay open. The iSCSI adapter page rules out port binding toward targets in another subnet, while the software iSCSI best practices show bound ports reaching one through a static route or a gateway per VMkernel port21. Until Broadcom aligns them, our recommendation is to bind only ports in the target subnet. Round Robin settings beyond the latency mechanism appear only as esxcli parameters10, so the array vendor’s values apply. Limits on LUNs, paths and VMFS size sit in the configuration maximums32, not reviewed here.
Our recommendation is to hold every production migration while any item lacks its evidence. The safe stopping point is the finished cluster with its datastores mounted and only test VMs on them. A failed configuration item is corrected and its evidence collected again from every host, and a claim rule counts only once the rebooted host’s device list shows the new policy. A failed test is repeated after the fix on every affected host, with the measured pause or VM Component Protection event recorded. A host crash during an array controller or firmware change goes to the array vendor, and the retry needs its fix confirmed.
Sources
Show all 41 sources
- Start a New vSphere Foundation Deployment by Using the VCF Installer Deployment Wizard
- ESX 9.1.1.0100 Release Notes
- Bill of Materials 9.1.1
- VMware Cloud Foundation 9.1.1 and VMware vSphere Foundation 9.1.1: Feature Comparison & Upgrade Paths
- Comparing Types of Storage
- About VMware NVMe Storage
- Requirements for VMware NVMe Storage
- Using Pluggable Storage Architecture and Path Management with ESX
- VMware SATPs
- VMware Path Selection Plug-Ins and Policies
- Multipathing Considerations
- Define NMP SATP Rules
- VMware High Performance Plug-In and Path Selection Schemes
- Change the Path Selection Policy
- Preventing Fibre Channel SAN Problems
- Using Claim Rules to Control ESX Multipathing Modules
- Change Default Parameters for Latency Round Robin
- Understanding Multipathing and Failover in the ESX Environment
- Multiple Network Adapters in iSCSI or iSER Configuration
- Configure Port Binding for iSCSI or iSER on ESX
- Best Practices for Configuring Networking with Software iSCSI
- Limitations of the LACP Support on a vSphere Distributed Switch
- vSphere Networking Best Practices
- NFS Multipathing
- NFS Networking
- Configure Multiple TCP Connections for NFS with the esxcli Command
- NFS Datastore Concepts and Operations in vSphere Environment
- NFS Server Configuration
- NFS Datastores
- vSphere Hardware Acceleration on NAS Devices
- Making LUN Decisions
- vSphere VMFS Datastore Concepts and Operations
- Datastore Cluster Requirements
- Manage Storage I/O Resources with vSphere
- Datastore Heartbeating
- ESX 9.1.1.0 Release Notes
- Identifying ESX Storage Connectivity Problems
- Handling Transient APD Conditions
- Detecting PDL Conditions
- VM Component Protection
- Recovering from PDL Conditions