Sizing a VM on vSphere Foundation 9.1.1 comes down to four choices: the vCPU count and memory size, CPU hot add, the resource settings (shares, reservations and limits), and the counters that show a wrong size. Broadcom’s Performance Best Practices for vSphere 9.1 sets no vCPU count for a VM and no vCPU-to-core ratio. It says to give each VM only the virtual hardware it requires, because over-provisioning can in some cases slow that VM and others on the same host. In most environments, it says, ESX allows full CPU commitment, and even significant overcommitment, without hurting VM performance, although a saturated host can slow some or all of its VMs, latency-sensitive workloads in particular1. The baseline is vSphere Foundation 9.1.1 with the patches of October 12, 2026, ESX 9.1.1.0100 and vCenter 9.1.1.0100, both security releases23.
Our recommendation is to keep each VM inside one physical NUMA node where the workload allows, leave the CPU topology automatic, keep CPU hot add off on VMs wider than a node, use shares for priority and reservations only for a guaranteed minimum, avoid limits, and resize a VM only on usage, ready time, Active memory and application response measured through its busiest period.
Broadcom’s 9.1.1 feature comparison lists vSMP, DRS and vSphere HA for vSphere Foundation4, and the 9.1.1 Bill of Materials marks ESX and vCenter as vSphere Foundation components5.
Start from the workload and the NUMA node
A single-threaded application belongs on a one-vCPU VM. A second vCPU does not speed it up and takes physical resources that other VMs could use6. Idle vCPUs are not free either. Some guests still take timer interrupts on them, keeping a consistent memory view across vCPUs costs resources in the guest and in ESX, and the guest scheduler may move a single-threaded workload between vCPUs and lose cache locality1. At the other end, a VM with ESX 9.1 compatibility can have up to 960 vCPUs, but never more than the host has logical CPUs7.
The physical NUMA node sets the practical limit. ESX gives each VM a home node, allocates its memory there by preference and keeps its vCPUs on that node8. A VM with no more vCPUs than the cores in one node runs entirely inside it, with local memory as far as the node’s free memory allows. A wider VM spans two or more nodes and can see higher average memory latency. Broadcom’s sizing advice follows: keep a VM within one physical NUMA node where possible, and when it must be larger, split it evenly across as few nodes as possible. A vCPU count above the host’s physical core count relies on hyper-threads and can create contention. By default these optimizations run only on hosts with at least four cores and at least two cores per NUMA node, and if node interleaving is enabled in the BIOS, ESX does not detect the host as NUMA at all1.
Our recommendation is to read the node size from the hardware, not from the socket count. Some 12-core processors present two six-core NUMA nodes, Broadcom advises sizing VMs to the NUMA node and SNC domain boundaries of Intel Granite Rapids processors, and the NPS setting on AMD EPYC changes how many nodes each socket presents. On hyper-threaded hosts, a VM with more vCPUs than a node has cores, but fewer than its logical processors, can be set to prefer hyper-threads with local memory through numa.vcpu.preferHT1.
vNUMA and cores per socket
vNUMA presents a virtual NUMA topology to the guest and is activated by default when a VM has more than eight vCPUs9, because numa.vcpu.min defaults to 910. The topology is derived from the physical host the first time the VM powers on and does not change unless the vCPU count changes9. A VM that later runs on hosts with a different NUMA layout keeps a topology that may no longer fit, which is why Broadcom says vNUMA gives the most benefit in clusters whose hosts share one NUMA architecture. A wide VM with eight or fewer vCPUs gets vNUMA only if numa.vcpu.min is set to its vCPU count1.
Cores per socket no longer shapes vNUMA. Since vSphere 6.5 it changes only how sockets and cores are presented to the guest, which matters for software licensing1, and setting numa.vcpu.followcorespersocket to 1 restores the old coupling10. From ESX 8.0, VMs at hardware version 20 or later get coresPerSocket and the virtual L3 cache size chosen automatically, and the VM Options tab still allows a manual CPU topology11. ESX 9.1 supports hardware version 22, which cannot run on hosts older than 9.01. Multicore settings must stay within the guest operating system’s license terms7, and some manual values produce guest topologies that map poorly onto the physical nodes1.
Broadcom documents automatic topology as the default for current hardware versions. Our recommendation is to leave it automatic unless a license says otherwise, and in that case to choose a cores-per-socket value that divides evenly into the physical node size.
What hot add costs
Enabling CPU hot add deactivates vNUMA, so the guest sees a single node and schedules without knowing the host topology, which can slow applications in large VMs19. Hardware version 20 brought a virtual motherboard layout that can expose vNUMA with CPU hot-plug, yet by default a hot-plug VM is still held to one virtual NUMA node. Hot-added CPUs reach a new node only with numa.allowHotadd and a manual NUMA configuration11.
Enabling hot add needs the VM powered off, a guest that supports it and current VMware Tools. A VM with 128 vCPUs or fewer cannot be hot-added past 128, and adding CPUs to a running VM disconnects and reconnects its USB passthrough devices12. Memory hot add creates some memory overhead on the host13. Broadcom advises activating CPU hot add only if you expect to use it, and otherwise powering the VM down to add vCPUs or configuring the most it will need, accepting a small overhead from unused vCPUs, which can also lead the guest to poor scheduling decisions1. Our recommendation is to plan a power-off instead of hot add for a VM wider than one physical node, since hot add removes the topology such a VM depends on. Reducing vCPUs needs a power-off in any case, because hot add only increases the count14.
Shares, reservations and limits
Broadcom’s advice is to use these settings only where they are needed1. Shares set relative priority when VMs compete for a resource. Low, Normal and High stand in a 1:2:4 ratio and Custom sets a specific weight15. Because shares are relative, a VM keeps its priority after a hardware upgrade, which makes them the better tool where total capacity changes often16.
A reservation is a guaranteed minimum, to be set at the minimum acceptable amount rather than the amount you would like16. At power-on, admission control checks unreserved CPU and memory, counting each VM’s overhead memory as well, and a VM whose reservation cannot be met does not start1718. Leave at least 10 percent of capacity unreserved. As reservations approach full commitment, changing them gets harder, and in a DRS cluster they can stop DRS from migrating VMs between hosts16.
A memory reservation also shrinks the VM’s swap file, which ESX sizes as configured memory minus reservation. Reserving at least the active working set reduces host-level swapping for that VM and reserving all of its memory eliminates it, at the cost of fewer VMs per host. Latency-sensitive VMs are the documented case for full reservations. High latency sensitivity requires a 100 percent memory reservation, VMs at hardware version 14 or later also need a full CPU reservation to power on unless latency.enforceCpuMin is set to FALSE, and the cores they are given are then unavailable to other VMs1. When a host runs short of memory, the documented remedies include lowering a memory reservation set much higher than the VM’s Active memory, so the VMkernel can reclaim the idle memory19. Full reservations also apply to VMs taken out of NVMe memory tiering, as the memory tiering article describes.
Limits need a good reason, the vSphere documentation says. CPU and memory limits default to unlimited, and for memory the configured size then acts as the limit. A limit holds a VM back even when the host has idle capacity20. In esxtop, time a VM loses to its limit appears as %MLMTD and is counted inside %RDY21, and the vSphere CPU troubleshooting steps include checking whether high ready time comes from a CPU limit22.
Memory size and overcommit
Give a VM enough memory to hold its application’s working set, since under-allocation causes thrashing, which costs far more than over-allocation. Over-allocation is not free either: the guest fills the surplus with file cache that ballooning can reclaim, but the extra overhead memory that comes with it cannot be reclaimed1. The monitoring guide gives the target: memory slightly larger than the VM’s average guest memory usage, so the host can absorb spikes without swapping19. Configured memory above physical memory is not overcommitment in itself. A host is overcommitted when the combined working memory of its VMs exceeds its memory23.
When that happens, ESX reclaims memory in stages: page sharing, ballooning, compression, swap to host cache and regular host swapping. Since vSphere 6.0, page sharing between VMs by default happens only for VMs with the same salt value. Broadcom asks you to avoid overcommitting to the point where regular swapping reaches active pages, and says the point at which overcommitment starts to hurt depends heavily on the workload1. No ratio follows from that.
Counters that show a VM is the wrong size
CPU ready is the share of time a VM was ready to run but could not be scheduled, and it rises with the number of VMs on the host and their load. At statistics level 1 the chart shows ready time averaged across all of a VM’s vCPUs, and level 3 adds each vCPU. Short spikes are normal, but CPU usage above 90 percent together with ready above 20 percent means performance is impacted. The remedies listed for that case include ruling out a CPU limit, raising shares or reservations for high-priority VMs and cutting vCPUs to the number the workload needs, and the page notes that VMs with smaller resource allocations generally accumulate more ready time22. For the host, a load average of 1 or more on the first line of the esxtop CPU panel means it is overloaded, and physical CPU usage of 80 percent is a reasonable ceiling, with 90 percent as a warning, although organizations set their own standards1.
Co-stop appears in esxtop as %CSTP, the time spent in a ready, co-deschedule state, which the 9.1 esxtop reference marks for VMware use only21. The VM CPU chart documents usage and ready22, and our recommendation is to judge any change in vCPU count by ready time and the application’s own response times.
For oversizing, VM CPU usage is averaged over all of its vCPUs, measured from the host’s side22. An eight-vCPU VM that peaks at 25 percent usage is therefore doing about two vCPUs’ worth of work at its busiest. If that holds through a full business cycle, our recommendation is to remove vCPUs in steps and check ready time and application response after each one.
For memory, compare Active with Granted and Consumed. Active is the VMkernel’s sampled estimate of the guest memory in use. If active equals granted, demand exceeds the memory available, and if active stays low, the VM’s memory may be too large. A high balloon value causes no performance problem when enough swap space is available, the page says without naming guest or host, while large swap-in and swap-out values for the host mean it is probably short of memory. Swapped counts VMkernel swapping, not swapping inside the guest19. Broadcom adds that some ballooning is normal and that no ballooning, with a working balloon driver, suggests the host is not under heavy memory pressure. Consumed above active suggests the guest has all the memory it needs. Non-zero Swapped or Compressed values under Monitor, Utilization, Guest Memory signal more serious pressure, and swapping inside the guest can mean ballooning has started to hurt1.
At host level, memory usage constantly at 94 percent or more, or free memory at 6 percent or less with frequent swapping, points to a host that probably lacks the memory for the combined active memory of its VMs. Usage constantly at 24 percent or less is listed as a symptom as well24. For wide VMs, the esxtop memory panel shows the current home node (NHN), the remote memory allocated (NRMEM) and the percentage of memory that is local (N%L)25.
vCenter keeps its 20-second real-time samples as 5-minute points for a day, 30-minute points for a week and 2-hour points for a month26, so monthly charts flatten the peaks that ready time and ballooning reveal. Per-vCPU ready needs statistics level 3 and Active needs level 21922.
Right-sizing checklist and holds
Our recommendation is to treat every vCPU or memory change as a small change with evidence and a way back.
- vSphere administrator: host layout. Evidence: cores per NUMA node per host model, from server documentation and BIOS (NPS, SNC, node interleaving off), and any cluster whose hosts differ. Our recommendation is to size wide VMs there to the smallest node.
- Application owner: workload profile. Evidence: whether the application is single-threaded, its busiest period and its response-time target.
- vSphere administrator: baseline. Evidence: CPU usage and per-vCPU ready at statistics level 3, and Active, Consumed, Balloon and Swapped from level 2, captured during the busiest period.
- vSphere administrator: current configuration on record. Evidence: vCPUs, cores per socket, memory, shares, reservations, limits, hot add and any
numa.*settings, exported before the change. - License owner: socket and core terms. Evidence: the guest operating system and application terms that a manual cores-per-socket value must meet7.
- Change owner: power-off window. Evidence: an approved window per VM, since a vCPU reduction needs a power-off14.
The safe stopping point is the VM running on its recorded configuration. Our recommendation is to hold there when any checklist item is missing or the baseline misses the busiest period. Hold as well when the host is the problem: a load average of 1 or more, physical CPU above 90 percent, or free memory at 6 percent or less with frequent swapping124 points to placement or capacity, not to the VM’s size. After the change, revert to the recorded configuration when application response misses its target, per-vCPU ready rises above the baseline, usage above 90 percent comes with ready above 20 percent22, Active reaches Granted, or Swapped or Compressed values appear119. Retry only with this evidence: a fresh baseline through the busiest period, the reverted VM’s counters back at their earlier level, and a smaller step than the one that failed.
Three points stay open. No page checked gives a threshold for co-stop, and its only documented counter is marked for VMware use. The CPU hot add page asks for one core per socket on VMs with ESX 7.x or later compatibility, while the page on changing the vCPU count supports hot-adding multicore vCPUs in multiples of the cores per socket1214. And no ready-time figure is given for a VM below 90 percent usage.
Our recommendation is to start with the widest VMs in each cluster and schedule power-offs one VM at a time in existing maintenance windows.
Sources
Show all 26 sources
- Performance Best Practices for VMware vSphere 9.1
- ESX 9.1.1.0100 Release Notes
- vCenter 9.1.1.0100 Release Notes
- VMware Cloud Foundation 9.1.1 and VMware vSphere Foundation 9.1.1: Feature Comparison & Upgrade Paths
- Bill of Materials 9.1.1
- Performance Implications of CPU Virtualization
- Virtual CPU Configuration and Limitations
- How ESX NUMA Scheduling Works
- Using Virtual NUMA
- Virtual NUMA Controls
- Virtual Topology in ESX
- Enable CPU Hot Add
- Change Memory Hot Add Settings
- Change the Number of Virtual CPUs
- Edit Settings in vSphere
- Resource Allocation Settings Suggestions
- Admission Control in vSphere
- Allocate Memory Resources to a Virtual Machine
- Memory (MB)
- Resource Allocation Limit
- CPU Panel
- CPU (%)
- Memory Overcommitment
- Solutions for Memory Performance Problems
- Memory Panel
- Data Collection Intervals