Broadcom’s vSphere 9.1 documentation fits NVMe memory tiering to hosts whose active memory stays below half of their DRAM, with some workloads tolerating up to about 75 percent12. A local NVMe device holds the cold pages, and by default the tier is as large as the DRAM3. Four choices follow: which hosts qualify, which device and mirror they get, which VMs stay in DRAM, and what evidence must exist before production VMs move onto a tiered host.
Our recommendation is to measure before buying: convert only hosts whose active memory at month-end or batch peaks stays below 50 percent, mirror the tier device on production hosts and keep the default 1:1 ratio. The baseline is vSphere Foundation 9.1.1 with the patches of October 12, 2026, ESX 9.1.1.0100 and vCenter 9.1.1.0100, both carrying security enhancements45. Broadcom’s 9.1.1 feature comparison of November 16, 2026, lists memory tiering for vSphere Foundation6, and the 9.1.1 Bill of Materials marks ESX and vCenter as its components7.
What the NVMe tier holds
DRAM is tier 0 and NVMe is tier 1, and NVMe pages serve only VM memory allocations3. Kernel memory is never tiered. Cold pages start moving to NVMe once host memory consumption reaches about 80 percent of DRAM. From then on ESX moves pages between the tiers by how recently and how often they were used, at a CPU cost of about an eighth of a core on smaller hosts8. Overhead memory stays in DRAM for every VM, tiered or not9.
Tiering suits hosts with more than 50 percent of memory allocated across all VMs and active memory below 50 percent of DRAM1. The capacity planning page asks that host active memory not exceed half of DRAM at any point10. Broadcom notes that most workloads keep active memory between 10 and 30 percent8. The 9.1 best practices guide adds two conditions: NVMe read latency ideally below 200 microseconds, with some workloads unaffected until it approaches 400, and enough CPU headroom for tiering itself2.
Broadcom says not to use memory overcommit while tiering is active8, so the NVMe tier replaces DRAM you would otherwise install. A tiered host also carries more hypervisor overhead, by Broadcom’s representative figures about 2 percent of memory for a 1 TB host without tiering and about 7.96 percent of total memory for a host with 512 GB of DRAM and 512 GB of NVMe11. The sizing has to absorb the difference.
Hosts and NVMe devices
Tiering needs vCenter and ESX 9.1 or later and an NVMe device installed in the host itself. Devices reached over fabric or Ethernet are not supported. Broadcom asks for a drive similar to a vSAN cache device, mixed use with 3 drive writes per day, and gives Compatibility Guide filters in the vSAN SSD category: NVMe, endurance class D (7,300 TBW or more), performance class F or G (100,000 writes per second or more) and 3 DWPD or more. A configured vSAN cache or data disk cannot be used, and every existing partition must be deleted first3. KB 323144 describes how to delete them. The whole device belongs to tiering and cannot be shared with boot or vSAN, even when tiering uses only part of it12.
In a vSAN cluster, keep the tiering device out of vSAN by switching off vSAN managed disk claim and claiming the other disks by hand, or remove a device from vSAN with full data migration after checking that the cluster has room for its data13. Broadcom’s Dell guidance notes that a ReadyNode may need a different pair of NVMe drives for tiering than the ones it uses for vSAN8.
The host must not have Intel Optane persistent memory or NVDIMM-N modules installed. Suspending VMs to memory is not supported, while suspend to disk and snapshots are, and Quick Boot is unavailable on a host with tiering active. The tier device cannot be hot-plugged or prepared for removal. The overview page requires tiering to be deactivated before the device is removed or replaced3, the configuration page’s replacement steps only maintenance mode14. Our recommendation is to deactivate tiering in maintenance mode before replacing a device, which satisfies both pages.
One device is a single point of failure for the VMs with pages on it. If a VM touches a page on a failed device, that VM powers off, while VMs whose memory sits entirely in DRAM keep running. vSphere HA restart policies can restart the powered-off VMs on other hosts, and in 9.1 placing the failed host into maintenance mode is a manual step unless a hardware management plug-in does it15. vSphere 9.1 adds software mirroring across two NVMe devices, with the mirror at least as large as the first device, and Broadcom recommends it over hardware RAID, although NVMe devices behind a supported RAID controller remain an option14. Our recommendation is to mirror any host that carries production VMs. It costs a second qualifying drive per host and removes the power-off case above for a single device failure. Tier contents are not encrypted by default. Encryption can be switched on per host, in maintenance mode, or per VM with sched.mem.EncryptTierNVMe, with the VM powered off14.
Choosing the DRAM to NVMe ratio
The tier size is a percentage of DRAM, set as tier_size_pct (1 to 400) in Configuration Manager or with --tier-size-pct in ESXCLI. The default of 100 gives a 1:1 ratio, which Broadcom recommends for optimal performance, and changing the ratio requires maintenance mode14. By default the tier is capped at 4 TB3, and the host uses whichever is smaller, the ratio or the NVMe partition. Broadcom also asks for NVMe at least as large as DRAM and suggests revisiting the ratio once historical active memory is known8.
Broadcom’s capacity planning asks for two DRAM figures: the memory of VMs that must stay entirely in DRAM, and the DRAM and NVMe implied by memory reservations10. Our recommendation is to size from those measurements rather than from the ratio. DRAM has to hold every DRAM-only VM at full size, and the peak active memory of the tiered VMs at no more than half of the DRAM left to them. The NVMe tier covers consumed memory beyond that. Take a host planned for 1.5 TB of consumed memory with 400 GB active at peak and no DRAM-only VMs. It needs at least 800 GB of DRAM, so 1 TB of DRAM with a 1:1 tier gives 2 TB of nominal capacity, before the overhead above, and room to grow. Less DRAM per host lowers the ceiling on active memory, and for the same workload the only way back under it is to move VMs off or add DRAM.
Which VMs stay in DRAM
ESX 9.1 runs some VM types on a tiered host but excludes them from tiering: VMs with 1 GB pages, confidential, Fault Tolerance, large, low-latency, nested virtualization, PCI passthrough, preallocated and vQAT VMs16. KB 398302 records the ESX 9.0 behavior this replaced: such VMs failed to power on or migrate to a tiered host.
The 9.1 profile page warns that VMs with more than 512 GB of memory and 64 vCPUs may lose performance on a tiered host, and asks for tiering to be deactivated for them, with full memory reservations16. KB 398302 uses a higher mark for the “monster” VMs that 9.1 keeps out of tiering automatically: more than 1 TB and 128 vCPUs. Our recommendation is to exclude any VM above the lower mark by hand rather than rely on the automatic exclusion.
Windows VMs with VBS count as nested virtualization, the only nested Hyper-V use vSphere supports17, and nested virtualization VMs are excluded from tiering by default. The 9.1 profile page names VBS VMs as the one exception, which can take part once sched.mem.enableNestedTiering is set to TRUE and the workloads have been tested16, and KB 398302 says the same. Broadcom’s Performance Best Practices for vSphere 9.1 says the opposite: vSphere 9.1 does not support VBS with memory tiering2. Our recommendation is to get the support position from Broadcom Support before relying on the opt-in, and until then to size hosts that run mostly VBS-enabled Windows VMs as DRAM-only, because their memory stays in DRAM and tiering lowers no RAM cost for them.
Broadcom notes that some VMs need tiering deactivated to meet performance or latency requirements. To exclude one, power it off, set sched.mem.enableTiering to FALSE, select Reserve all guest memory (All locked) and power it on again14. The full reservation is required because otherwise other VMs keep tiering and the excluded VM can end up in the host swap file, which performs worse than the NVMe tier15.
Every exclusion shrinks the DRAM left for tiered VMs. In Broadcom’s example, a host with 1 TB of DRAM and 1 TB of NVMe that fully reserves two 200 GB VMs loses 400 GB of DRAM from the tiering pool, the effective ratio for the remaining VMs drops to about 0.6:1, and their performance can suffer15.
HA admission control from 9.1.1
In vSphere 9.1 and earlier, HA admission control counted DRAM and NVMe as one pool. A tiered cluster could report enough failover capacity and still fail to restart VMs after a host failure, because VMs cannot restart on NVMe capacity. From 9.1.1, under the Cluster Resource Percentage or Dedicated Failover Hosts policy, admission control tracks DRAM as a separate resource and admits a VM only if a total memory check and a DRAM check both pass. The Slot Policy still treats memory as one pool, and Broadcom says not to use it with tiering. A DRAM shortfall uses the existing failover capacity violation alerts and green, yellow and red status, with no new alert type9. The vCenter 9.1.1.0 release notes list this change together with DRS support for memory tiering18.
At restart, a tiered VM needs DRAM for its overhead memory, while its configured reservation is served from NVMe. A non-tiered VM needs both its reservation and its overhead in DRAM9. Each VM excluded with a full reservation therefore adds its whole memory to the DRAM the surviving hosts must hold, on top of its cut in the tiering pool. The cluster and host design article compares how the two DRAM-aware policies reserve it.
Turning it on and off
Activating, deactivating or reconfiguring tiering needs the host in maintenance mode3, which evacuates its VMs with vMotion15. In 9.1 no reboot is needed, and setup moves to cluster level through vSphere Configuration Profiles2. In Configuration Manager, under the cluster’s Desired State Configuration, the esx memtier nvme settings hold the enable flag, devices, encryption and tier_size_pct, and hosts enter maintenance mode automatically14. vSphere Configuration Profiles cannot be deactivated once enabled19, so this is a lasting change to how the cluster is managed. The cluster and host design article lists what else that choice rules out, such as stateless hosts.
The ESXCLI route needs the same cluster managed by a single image and vSphere Configuration Profiles. In maintenance mode, esxcli memtier device list shows candidate devices and esxcli memtier enable -d activates one device, or a comma-separated mirror pair14.
A configured host shows Software in the Memory Tiering column of the cluster’s Hosts tab, and its hardware overview lists Tier 0, Tier 1 and their total20. esxcli memtier status get reports the live state. If the configuration says enabled but the status reads Disabled, activation failed and the logs or alarms give the reason14.
Backing out also goes through maintenance mode. esxcli memtier disable keeps the tier partition and adding -d deletes it. Deactivating tiering removes memory from the cluster, and in an overcommitted cluster VMs might then fail to power on14. Our recommendation is to confirm before the first host is converted that the cluster could carry its VMs on DRAM alone. If it could not, rolling back becomes a hardware purchase.
Pilot and sign-off
Broadcom gives thresholds but no acceptance procedure, so our recommendation is a pass or fail pilot. The VM Active counter is collected from statistics level 221. vCenter keeps 5-minute points for one day by default, then rolls them into coarser ones, although that interval can be lengthened22. Read month-end or batch peaks on the day, or lengthen that interval first, because averages flatten it, and watch the 20-second real-time view during the peak itself, since 5-minute averages can hide short bursts.
After tiering, write bandwidth in the Advanced memory chart shows cold pages moving to NVMe, and read bandwidth shows pages fetched back when they become active. Above 200 MB/s of reads, Broadcom says to watch device latency in the same chart, and per-VM read bandwidth isolates a poorly performing VM1. Under Monitor, Memory Tiering, Warning, for example spare capacity below 30 percent, means replace the device as soon as possible, and Error, below 10 percent or a read-only device, means replace it immediately23. esxcli nvme device log smart get adds lifespan and wear data24. vMotion of a tiered VM takes 1.5 to 2 times longer because its pages come from NVMe first8. Our recommendation is a pass mark of 200 microseconds or less for NVMe read latency, although Broadcom allows up to about 400 for some workloads2. No source gives a CPU headroom figure, so the owner sets one.
Our recommendation is to close these items before production VMs run on a tiered host.
- Workload fit. Owner: capacity planner. Evidence: host active memory through a business cycle, month-end or batch peaks included, with the highest 5-minute average and the real-time reading at the peak below half of the DRAM left to tiered VMs, after DRAM-only VMs at full size.
- Tier devices. Owner: server team. Evidence: Compatibility Guide entries matching Broadcom’s filters, local devices without partitions or vSAN claims, a mirror at least as large, no persistent memory modules, and
esxcli memtier device listshowing the device and its mirror. - DRAM-only VMs. Owner: virtualization architect with application owners. Evidence: VMs above 512 GB and 64 vCPUs and latency-sensitive VMs listed and excluded with
sched.mem.enableTieringFALSE and All locked, and a written Broadcom Support answer before any VBS opt-in. - HA. Owner: virtualization architect. Evidence: vCenter 9.1.1 or later, the Cluster Resource Percentage or Dedicated Failover Hosts policy, and admission control green with the DRAM check in place.
- Rollback capacity. Owner: capacity planner. Evidence: a calculation showing the cluster carries its VMs on DRAM alone. A hardware budget is not rollback capacity.
- Activation. Owner: virtualization engineer. Evidence: Software in the Memory Tiering column, the expected tier sizes, the live status matching the configuration, and encryption as decided.
- Pilot performance. Owner: virtualization engineer with application owners. Evidence: after each step of added VMs, active memory against Figure 3, NVMe read latency at or below 200 microseconds, CPU headroom above the owner’s figure, and database query and Windows logon times measured before tiering and after each step, within tolerances the application owners set before the pilot.
- Operations. Owner: operations team. Evidence: device health Healthy on every host, SMART data recorded, an alert route for Warning and Error, a timed host evacuation that fits the maintenance window, and a shutdown plan for any VM that cannot move with vMotion.
Some points remain open. The 9.1 profile page lists “Large VM” as excluded without defining it, apart from its 512 GB and 64 vCPU guidance and the higher mark in KB 39830216. The device replacement and VBS conflicts stand. The 50 percent guidance is stated for normal operation, and nothing checked says whether it should hold on the surviving hosts after a failover. Our recommendation is to size so that the surviving hosts stay under it after a host failure, or to add a host-failure step to the pilot.
Our recommendation is to hold every production host conversion while any item lacks its evidence. The safe stopping point is the pilot: tiering only on pilot hosts with test or non-critical VMs, every other host on DRAM alone. A host that fails workload fit stays DRAM-only until its month-end or batch peak, after VMs move off or DRAM is added, falls below half of the DRAM left to tiered VMs. A failed device, VM list, HA or rollback item blocks activation until its evidence is collected again. A failed activation is deactivated in maintenance mode and retried once the cause in the logs or alarms is fixed, and it passes only with the status matching the configuration, the expected tier sizes and encryption as decided. A failed pilot step is reversed by excluding the affected VMs or deactivating tiering, and repeated only when every Figure 3 measurement and the application times are back within their tolerances. A device in Warning or Error is replaced first, and the retry needs it Healthy. A failed operations item is retried with the host evacuation timed within the window, the alert route tested and the shutdown plan approved.
Sources
Show all 24 sources
- Assessing Customer Workloads for Memory Tiering
- Performance Best Practices for VMware vSphere 9.1
- Memory Tiering over NVMe
- ESX 9.1.1.0100 Release Notes
- vCenter 9.1.1.0100 Release Notes
- VMware Cloud Foundation 9.1.1 and VMware vSphere Foundation 9.1.1: Feature Comparison & Upgrade Paths
- Bill of Materials 9.1.1
- Memory Tiering Considerations and Best Practices
- Memory Tiering and HA Admission Control
- Capacity Planning Considerations
- The Reservable Memory is Lower than Expected
- Memory Tiering Configuration Parameters
- Activate Memory Tiering with vSAN
- Memory Tiering Configuration
- NVMe Failure Scenarios for Memory Tiering in vSphere
- Virtual Machine Profiles and Performance with Memory Tiering
- Expose VMware Hardware Assisted Virtualization
- vCenter 9.1.1.0 Release Notes
- What is vSphere Configuration Profiles
- Memory Tiering Troubleshooting Information
- Memory (MB)
- Data Collection Intervals
- View Memory Tiering Device Information
- NVMe Device Health Monitoring