For a new deployment, most of a vSphere Foundation network design is settled in the VCF Installer deployment wizard: the switch profile and the NICs per host, the uplink mapping, the MTU per traffic type, and the VLANs and IP inclusion ranges1. The VCF management subnet is sized at the same time, because later services runtime ranges must sit on it too2. Teaming, Network I/O Control and gateway firewall rules can still change later. The baseline is vSphere Foundation (VVF) 9.1.1 with the October 12, 2026, patches.
Broadcom’s 9.1.1 feature comparison of November 16, 2026, marks IPv4 and IPv6 routing, dynamic routing, NAT and L2 and L3 VPN only for the VCF editions, and gives vSphere Foundation the distributed switch, LACP, load-based teaming, Network I/O Control and private VLANs. It also lists VMware vDefend Firewall with ATP as a separately purchased advanced service for vSphere Foundation3. Gateways and routes between VLANs stay on the physical network in any case, and without that add-on so does any firewall between subnets, unless you deploy your own.
What the physical network has to route and filter
The vSphere 9.1 networking best practices ask for the host management, vMotion and Fault Tolerance networks to be isolated from one another. Where services are separated by switch or VLAN, the administrator should confirm those networks are isolated from the rest of the environment, with no routers connecting them. They put vMotion on the vMotion TCP/IP stack for migration across IP subnets, with cold migration and cloning on the provisioning stack. Multihoming, meaning more than one VMkernel adapter in the same IP subnet and TCP/IP stack, is not supported4. KB 318546 names exceptions such as iSCSI port binding and multi-NIC vMotion, and adds that vSAN does not support multihoming across its VMkernel adapters either.
Our recommendation is to let the vMotion subnets route only to each other, through the vMotion stack’s own gateways, with no route to user or workload networks.
For filtering, the same page suggests firewalls running in virtual machines that route between virtual networks with physical uplinks and purely virtual networks that have none4. Without the vDefend add-on, traffic between subnets is inspected at such an appliance or at the firewall on the VLAN gateway, and two VMs on the same VLAN reach each other without passing either.
Within one VLAN, private VLANs, marked for vSphere Foundation3, give isolated ports that reach only promiscuous ports, and need a private VLAN-capable physical switch configured with the same VLAN IDs5. The traffic filtering and marking policy applies ordered rules at the VM’s distributed port or the uplink, and is not supported on a switch with Network Offloads Compatibility6. Its page describes no connection tracking, so on that evidence the policy does not replace a stateful firewall. Private VLANs isolate ports but do not by themselves send traffic through a firewall. Workloads that must be inspected from one another therefore go on separate VLANs routed through one, and each adds a gateway interface and rules on that device.
Picking a switch profile in the wizard
vCenter pushes the switch configuration to a proxy switch on each host, with uplinks mapped to physical NICs and the VLAN, teaming and security policy set on port groups7.
The vSphere Foundation deployment wizard, which needs VCF Installer 9.1.1 or later, offers three distributed switch profiles. Default Configuration puts all traffic types on one switch. Storage Traffic Separation creates two switches on separate physical NICs, one for storage and the other for everything else. Custom Switch Configuration starts from a copy of a preconfigured profile or from nothing and can define several switches. It stays incomplete until the mandatory traffic types are placed, and VM management, VCF management, vMotion and vSAN can each be configured only once per cluster. For every switch you set the number of uplinks and map each one to a physical adapter on the host1, so a redundant pair costs two NICs per switch.
Our recommendation is Default Configuration for hosts with two fast NICs, with Network I/O Control setting priorities under contention. Storage Traffic Separation suits storage with its own physical fabric, such as a dedicated NFS network, or storage that must stay out of reach of a vMotion burst. It needs four NICs per host instead of two. The best practices prefer a separate physical network for vMotion to a VLAN on a shared one, because vMotion carries guest memory, and suggest one switch per service where services must be physically separated. They also say that physical adapters on the same distributed switch should connect to the same physical network4, which rules out one uplink on the storage fabric and the other on the data-center network.
VLANs and addresses for each network
The wizard separates three management networks. ESX management carries the hosts, VM management carries vCenter and other core components, and VCF management carries VCF Operations and the wider management components. VM management can share the ESX management network and VCF management the VM management network, or each can be dedicated, which segments management traffic for security and compliance. vMotion and vSAN or NFS get their own port groups. The wizard takes IP inclusion ranges for the VCF management, vMotion and vSAN networks, contiguous or not, with at least one address per ESX host. The addresses must belong to the VLAN of the network’s port group and exclude the network and broadcast addresses. For NFS the page shows no range field, only an option to reuse the gateway, VLAN and MTU of ESX management, and an option to bind the datastore to its VMkernel adapter so NFS traffic cannot use another one1.
The planning list asks for unique FQDNs and static addresses with forward and reverse DNS for every component, one FQDN per ESX host, and one address per host on each of the vMotion and vSAN networks. All management services ranges go on the VCF management network, or on VM management where there is no dedicated one. The services runtime needs at least 10 addresses there, and 30 are recommended for new components and scale-out. Its internal block 198.18.0.0/15 has to move to 240.0.0.0/15 or 250.0.0.0/15 if the network already uses it, settable in the 9.1.1 installer UI. The Avi Load Balancer add-on takes addresses on the VCF management network or on a network connected to it2.
Dual-stack addressing appears only when the VCF Installer has both IPv4 and IPv6 configured, and the vMotion and storage networks then each get an IPv4 or IPv6 scheme1. A vSphere 9 Supervisor cannot create IPv6 clusters8, and Avi’s Supervisor requirements say its services do not support IPv69, so Supervisor and VKS workload networks are planned in IPv4.
Teaming, LAGs and LACP
The wizard offers five teaming choices: source port ID, physical NIC load, source MAC hash, IP hash, or an explicit failover order with active, standby and unused uplinks. The default, physical NIC load, moves some VM traffic to another active uplink when an uplink stays above 75 percent utilization, the default threshold, for 30 seconds. Software teaming such as source port ID or physical NIC load needs no bond or channel on the switch ports, which work as independent links. IP hash is the exception: the wizard page says it, like a LAG, needs LACP configured on the top-of-rack switches1.
The vSphere 9.1 IP hash page differs. It asks for a static 802.3ad EtherChannel with one port per uplink on a single physical switch or a stack, says LACP is not supported, requires Link Status Only failure detection with every uplink active, and limits static EtherChannel to vSphere Standard Switches10. With the two pages at odds, our recommendation on a vSphere Foundation distributed switch is a LACP LAG where aggregation is needed, and no IP hash until Broadcom aligns them.
A distributed switch supports up to 64 LAGs and a host up to 32, although KB 324555 says 64 per host, so plan for 32. Each LAG needs two or more ports, every host needs its own LACP port channel on the physical switch with as many ports as the NICs it groups, all at the same speed and duplex, and the hashing algorithm on both sides must match11. LACP does not work with software iSCSI port binding, although iSCSI multipathing over a LAG without port binding does. Its settings are absent from host profiles. It is not possible between nested hosts and does not work with the ESX dump collector. LACP control packets are not mirrored when port mirroring is enabled, the teaming and failover health check ignores LAG ports, and only one LAG should handle the traffic of a port group12.
Our recommendation is to start from the default load-based teaming: it asks nothing of the physical switch and keeps the health check. A LAG fits a data-center standard of port channels to every server, and then every new or replaced host needs its own identical port channel. ESX supports link aggregation only on a single physical switch or on stacked switches, never across separate trunked switches, and changes to it belong in a maintenance window (KB 324555). The KB lists vPC only as another name for link aggregation, not as a supported topology, so our recommendation is to confirm support with Broadcom before building a LAG across a multi-chassis pair.
Network I/O Control on shared uplinks
For quality of service, the comparison lists Network I/O Control alone for vSphere Foundation, where the VCF columns list Network I/O Control and NSX3. Version 3 reserves bandwidth for system traffic based on the capacity of each physical adapter and gives VM network adapters shares, reservations and limits, and SR-IOV is not available to VMs that use it13. vCenter propagates the switch’s allocation to each physical adapter of the connected hosts. The system traffic types include management, NFS, vSAN, vMotion, virtual machine and NVMe over TCP, and provisioning traffic such as cold migration and cloning has had its own control since vSphere 9.014.
Shares (1 to 100) only matter between traffic types active on the same adapter. A reservation is a minimum in Mbps on one adapter, and a limit is a ceiling in Mbps or Gbps. Reserved bandwidth that goes unused is lent to other system traffic, but not to virtual machine placement, and all reservations together cannot exceed 75 percent of the bandwidth of the lowest-capacity adapter15. A 1 GbE adapter may not join a switch whose allocation is built on 10 GbE adapters, because it cannot meet that allocation, and the fix is to take it out of Network I/O Control with the Net.IOControlPnicOptOut host setting16.
On a Default Configuration switch, our recommendation is to keep the settings few: higher shares for vSAN than for vMotion, modest reservations for management and storage, and VM traffic left on shares. Storage traffic serves every running VM on vSAN, while a vMotion that yields takes longer. When a large VM changes memory faster than the vMotion link carries it, vMotion throttles the guest to converge, which can cause CPU spikes and application failovers inside it (KB 408126). With lower shares, host evacuations run slower while vSAN is busy, and reservations count against the 75 percent ceiling even when their unused bandwidth is lent to other traffic. Under Storage Traffic Separation, storage shares its NICs with no other traffic type.
Setting the MTU
The wizard asks for an MTU per traffic type1, and the best practices ask for the same MTU on every VMkernel adapter of a distributed switch, since mixed values can cause connectivity problems4. For a Supervisor, Foundation Load Balancer requires an MTU of 1600 or more on any distributed port group8, and Avi’s requirements for a vSphere Foundation Supervisor ask for 1500 or more9. Our recommendation is to start a switch that may one day carry a Supervisor with Foundation Load Balancer at 1600 or above, with physical ports matching. Raising it later means changing every VMkernel adapter on that switch and every top-of-rack port carrying it.
Networks for a Supervisor
The 9.1.1 Bill of Materials marks the Supervisor as a vSphere Foundation component17. On the vSphere networking stack a Supervisor needs a load balancer on the vCenter management network, either Foundation Load Balancer or Avi. All hosts of its clusters connect to the same distributed switch, distributed port groups serve as workload networks, and the one that connects the control plane VMs is the Primary Workload Network18. With vSAN, both load balancers’ requirement pages ask for four hosts per cluster with at least two physical NICs89.
The Foundation Load Balancer requirements, which state support for vSphere Foundation, come down to these items, with every route built on the physical network8.
- The management network and the Primary Workload Network must reach the same physical network for every cluster but sit on different subnets.
- The management subnet needs one address per host VMkernel adapter, one for vCenter and three to five for the control plane.
- The load balancer takes up to three port groups: management, transit for the two-arm configuration, and virtual server for the VIP range. The transit network needs an address range for forwarding outgoing traffic to the workload networks.
- Its management port group must be routable to and from the Supervisor’s floating management IP.
- Workload networks must route to the VIP network and must not overlap one another.
- Each Supervisor needs its own private /16 for Kubernetes services, and DHCP is never used for VIPs.
The 9.1.1 comparison includes Layer 4 load balancing for the Supervisor in vSphere Foundation, lists Avi Load Balancer among the separately purchased advanced services, and recommends Avi for general-purpose or advanced load balancing3. Avi’s requirements for a vSphere Foundation Supervisor put the Controller and the Service Engines’ management interfaces on the management network, take VIPs from the data network, ask for four static management addresses for a three-node Controller cluster and five consecutive ones for the control plane, and rule out DHCP on workload networks used with Supervisor Services. The management network has to route to the ESX hosts, vCenter, the Supervisor and the load balancer, and its port table lists what a firewall in between has to allow9:
- Between Controllers: TCP 22, 443 and 8443.
- From Service Engines to Controllers: TCP 22 and 8443, and UDP 123.
- Between Service Engines: TCP 9001.
- From Controllers to vCenter and ESX, and from the Supervisor control plane to the Controllers: TCP 443.
Where the network team signs off
Our recommendation is to agree these items, each with an owner and evidence, before the wizard runs.
- Switch profile, uplinks per switch and the NIC each uplink maps to. Owner: virtualization architect. Evidence: a cabling sheet per host from each NIC to its top-of-rack port.
- VLAN IDs, subnets and gateways for every management, vMotion and storage network, trunked to every host port. Owner: network team. Evidence: a VLAN and subnet table that matches the wizard’s network page.
- Inclusion ranges with at least one free address per host, and a VCF management subnet with room for 30 runtime addresses besides the component FQDNs. Owner: network team. Evidence: IPAM reservations, a check that
198.18.0.0/15is unused or the replacement block chosen, and forward and reverse lookups for every FQDN. - Frame size end to end. Owner: network team. Evidence: switch port configuration at or above every MTU entered in the wizard, 1600 where a Supervisor with Foundation Load Balancer is planned.
- Uplink mode. Owner: network team. Evidence: independent trunk ports carrying every VLAN, or one LACP port channel per host with matching hash, speed and duplex on one switch or a stack.
- Routing and filtering. Owner: network and security teams. Evidence: the approved route table, with vMotion subnets routed only to each other, and the gateway firewall rule set, including the Avi ports where Avi is planned.
- Supervisor subnets, if one is planned. Owner: platform team. Evidence: separate management and workload subnets, the VIP range and a unique /16 for Kubernetes services.
Our recommendation is to hold the wizard while any item lacks its evidence. The safe stopping point is its validation step, before deployment starts, where you can go back to a page, or correct and re-upload the JSON specification, and re-run the validations1. Continue only when the missing evidence exists and the validations pass.
Several points remain open: the LACP conflict between the wizard and IP hash pages, LAGs across multi-chassis pairs, the LAG limit per host, a way to change the switch profile after deployment, and how vDefend Firewall with ATP is deployed on vSphere Foundation. Until Broadcom documents a change path, our recommendation is to treat the profile, the NIC count and the VCF management subnet as hard to change and to get them right before the wizard runs.
Sources
Show all 18 sources
- Start a New vSphere Foundation Deployment by Using the VCF Installer Deployment Wizard
- vSphere Foundation FQDNs and IP Addresses
- VMware Cloud Foundation 9.1.1 and VMware vSphere Foundation 9.1.1: Feature Comparison & Upgrade Paths
- vSphere Networking Best Practices
- Private VLANs
- What is Traffic Filtering and Marking Policy
- Setting Up Networking with vSphere Distributed Switches
- Requirements for Deploying vSphere Supervisor with Foundation Load Balancer
- Requirements for Supervisor Deployment with Avi Load Balancer and VDS Networking
- Route Based on IP Hash
- LACP Support on a vSphere Distributed Switch
- Limitations of the LACP Support on a vSphere Distributed Switch
- What is vSphere Network I/O Control
- Allocate Bandwidth for System Traffic
- Bandwidth Allocation Parameters for System Traffic
- Move a Physical Adapter Out of Network I/O Control
- Bill of Materials 9.1.1
- Supervisor Networking